Date: 2014-02-27 OS: Windows, Linux Etrack Incidents: 3704201 Errors/Problems Fixed: 3704201 - High memory utilization on Management Server or Indexer node. Applies to: Data Insight Management Server node and all Indexer nodes. Install/Uninstall Instructions: Apply this hotfix to Data Insight Management Server node and all Indexer nodes. This hotfix can be applied to Data Insight version 4.0RP4 only. FILE AFFECTED BY THIS PATCH: Windows: INSTALL_ROOT\DataInsight\bin\activityidx.exe INSTALL_ROOT\DataInsight\bin\mindexer.dll INSTALL_ROOT\DataInsight\pdb\activityidx.pdb INSTALL_ROOT\DataInsight\pdb\mindexer.pdb Linux: INSTALL_ROOT/bin/activityidx INSTALL_ROOT/lib/libmindexer.so By default, value of INSTALL_ROOT on Windows is "C:\Program Files\Symantec". value of INSTALL_ROOT on Linux is "/opt". NOTE: Please keep a backup of the files you are about to patch. This will be required in case you want to rollback the patch. Steps: Log into Data Insight Management Server and Indexer nodes and perform the following steps: 1. Stop Data Insight services: For Windows : From the command prompt, issue the following command: net stop DataInsightWatchdog net stop DataInsightComm net stop DataInsightConfig For Linux : From the command prompt, issue the following command: service DataInsightWatchdog stop service DataInsightComm stop service DataInsightConfig stop 2. For Windows : Take a backup of entire bin and pdb folders under the install location. For Linux : Take a backup of entire bin and lib folders under the install location. 3. Unzip the patch files to a temporary folder. In this folder, locate the "patches" folder. This folder contains binaries for 64bit Windows operating System and Linux 64bit operating system. Files provided in the patch are in the same directory hierarchy as those present on your system at "INSTALL_ROOT\DataInsight". Example: If you unzip hotfix to C:\temp, it will create the following folders under C:\temp: C:\TEMP\ +---README +---patches +---linux +---64bit +-------bin +-------lib +---windows +---32bit +-------bin +-------pdb +---64bit +-------bin +-------pdb 4. Copy the patch files to the install directory. For example, if you are patching a 64 bit Windows server installed at "C:\Program Files\Symantec\DataInsight", copy entire contents under "C:\temp\patches\windows\64bit" to "C:\Program Files\Symantec\DataInsight", replacing the original files with those from the patch. For linux, simply copy the contents of \bin folder to INSTALL_ROOT/DataInsight/bin folder and execute following command from INSTALL_ROOT/DataInsight/bin: chmod 744 activityidx Then copy contents of \lib folder to INSTALL_ROOT/DataInsight/lib folder. 5. Start Data Insight services: For Windows: From the command prompt, issue the following command: net start DataInsightConfig net start DataInsightComm net start DataInsightWatchdog For Linux: From the command prompt, issue the following command: service DataInsightConfig start service DataInsightComm start service DataInsightWatchdog start Additional Notes: 1. Apply this hotfix to Data Insight 4.0RP4 only.