Date: 2010-02-15 OS: Solaris 8, Solaris 9, Solaris 10, Windows 2000 Server, Windows 2003 Server, Windows 2008 Server Etrack Incidents: 1944031, 1510616, 1953488, 1923179, 1910005, 1937375, 1938641, 1929129, 1907351, 1913191, 1935250, 1935460, 1925753, 1933475 Errors/Problems Fixed:[ Cannot detect the correlation between unidentified adapters and hosts when using agentless rules (e1944031) Missing device handles not deleted from the database after the default purging period of seven days (e1510616) The "Allocation" bar includes a new capacity called "NAS Allocated" - see Note 1 below for more details (e1952870) No monitoring for Symmetrix arrays after you enable monitoring through the Edit Device Configuration wizard (e1923179) For backend Symmetrix arrays, incorrect data appears in the Array Overview and Total Online Storage charts (e1910005) When a device is configured by more than one explorer, the Console may display the wrong device status (e1929129) After upgrading to 5.1.1, the topology does not display the correct connections for virtual switches (e1907351) The Host Consumption report takes a long time to appear (e1913191) LUN icons indicate the wrong type of LUNs in several tables (e1935250) The Storage Pools table now indicates if LUNs allocated to storage pools are SAN, DAS, or mixed LUNs (e1935460) Path Management takes a long time to display the results in Storage Change Manager (e1925753) Monitoring does not work for Cisco switches - see Note 2 below for more details (e1933475) DMX4 Summary view in GUI is wrong (e1937375) Wrong numbers for DEVICE: Administrative & Virtualizer Source for EMC array Sym SID 80724 SymmetrixExplorer@xxxx.xxx.xxx (e1938641) Vmware Reports: Fully support NFS based volumes (e1953488) ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the hotfix --------------------------------------------------------------------------- Apply the hotfix (VRTSccsF512001950096) on the 5.1.2 Management Server Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 B - Deploying the hotfix on a Windows Management Server -------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win-5.1.2HF512001950096w.2.zip to a temporary location. For example, to C:\\Temp 2. Extract the file. After you extract it, the following files/directory are available - - patches\\ - patches\\VRTSccs-F512001950096.tar.gz - README (this file) 3. To apply the update, do the following: - Open an operating system console. - Change to the HAL bin directory: C: cd "\\Program Files\\VERITAS\\CommandCentral Storage\\HAL\\bin" - Type the following command to deploy the update on the Management Server: perl LocalUpgrade.pl C:\\Temp\\patches\\VRTSccs-F512001950096.tar.gz 4. To verify the installation, you can check the installation logs as follows: - The detailed logs are stored in a directory under the "CommandCentral Storage Data" directory. The default location is: "C:\\Program Files\\VERITAS\\CommandCentral Storage Data\\Data\\HAL\\maint\\VRTSccs-F512001950096\\[TIME STAMP]\\output" For example (note Timestamp is example only): C: cd "\\Program Files\\VERITAS\\CommandCentral Storage Data\\Data\\HAL\\maint\\VRTSccs-F512001950096\\20100208_16.43.33\\output" - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: "C:\\Program Files\\VERITAS\\CommandCentral Storage\\Version\\cc_version.txt" - Check the FIXID. It should appear as follows: FIXID=F512001950096 DATE=Wed Jan 27 18:20:51 2010 DESCRIPTION=5.1.2 HotFix: Jumbo Hotfix for CommandCentral Storage v5.1.2 PREREQUISITES=F512001896910 C - Deploying the hotfix on a Solaris Management Server --------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy the file ccs-sol_sparc-5.1.2HF512001950096u.2.tar.gz to a temporary location. For example, to /tmp and unpack it. 2. Unpack the file. After you extract it, the following files/directory are available - - patches/ - patches/VRTSccs-F512001950096.tar.gz - README (this file) 3. To apply the update, do the following: - Open an operating system console. - Change to the HAL/bin directory: cd /opt/VRTSccs/VRTShal/bin - Type the following command to deploy the update: ./perl LocalUpgrade.pl /patches/VRTSccs-F512001950096.tar.gz For example: ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F512001950096.tar.gz 4. To verify the installation, you can check the installation logs as follows: - To see the detailed logs, go to the "CommandCentral Storage Data" directory. The default location is: /var/VRTSccs/data/VRTShal/maint/VRTSccs-F512001950096/[TIME STAMP]/output For example: cd /var/VRTSccs/data/VRTShal/maint/VRTSccs-F512001950096/20091211_15.39.49/output - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: /opt/VRTS/version/cc_version.txt - Check the FIXID. It should appear as follows: FIXID=F512001950096 DATE=Wed Jan 27 18:20:51 2010 DESCRIPTION=5.1.2 HotFix: Jumbo Hotfix for CommandCentral Storage v5.1.2 GUI & DB PREREQUISITES=F512001896910 Additional Notes: ================== Note 1 ------ In the Host Virtualization Storage Summary chart, the "Allocation" bar (previously called "Claimed Status") includes a new capacity called "NAS Allocated". The "NAS Allocated" capacity includes the capacities of NFS-based storage pools. The Host Virtualization Summary chart appears in the Host Virtualization Summary report. Note 2 ------ After you apply this hotfix, an additional step is required to correct the following issue: Monitoring does not work for Cisco switches if the text entered in the "Cisco Switch IP Address or Name" field and "Configuration Name" field are different (e1933475) For the Cisco switches affected by this issue, you need to remove the device configuration and then re-configure the switch for discovery. When you re-configure the switch for discovery, you can now enter text in the �Cisco Switch IP Address or Name� field and �Configuration Name� field that are different. To remove the device configuration 1. Click Settings > Devices. 2. In the Configured Devices Summary table, select the Cisco switch. 3. From the drop-down list, click Remove Device Configuration. Then, click Go. 4. In the Remove Device Configuration dialog box, click OK. To re-configure the switch for discovery 1. From the Configured Devices Summary drop-down list, click Configure a New Device. Then, click Go. 2. Follow the prompts in the wizard to configure the switch for discovery.