Date: 2011-Apr-21 OS: Solaris, Windows Etrack Incidents: 2336617 Errors/Problems Fixed:[ Discovery of numeric controllers of HP Eva arrays happens now (e2336617) ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the HotFix --------------------------------------------------------------------------- Apply the HotFix (VRTSccs-F520012336617) on the 5.2RU1 Management Server and Control Hosts (Managed Hosts having array and switch explorers). Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 B - Deploying the HotFix from a Windows Management Server -------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win-5.2RU1HF520012336617w.zip to a temporary location. For example, to C:\Temp 2. After extracting the hotfix, the below two files will be available. - patches - patches\VRTSccs-F520012336617.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the CommandCentral HAL bin directory: "C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin" - Run the following command: perl LocalUpgrade.pl "C:\Temp\patches\VRTSccs-F520012336617.tar.gz" 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory. "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\ \VRTSccs-F520012336617\