Date: 2012-Oct-18 OS: Solaris, Windows Etrack Incidents: 2932101, 2962652, 2965962, 2957824, 2896795, 2869538, 2915491, 2903493, 2869371, 2875114, 2853118 Errors/Problems Fixed:[ - Number of active Data Collection Tasks (DCTs) are decreasing with time (e2932101) - HALCHM taking long time to process EMCSymmetrixExplorer DCT's (e2962652) - Storage Array LUN page takes long time to load(e2965962) - Some LUNs appear to be in the wrong Disk Groups (e2957824) - Brocade DCX discovery incorrect in GUI (e2896795) - Unhandled java exception on Thin Pool Tab page (e2869538) - Unable to export and email custom reports (e2915491) - CommandCentral Storage shows negative Overhead values of HITACHI Thin Pools (e2903493) - DCT takes long time and builds a DCT queue (e2869371) - LUNs are missing from the CCS Database (e2875114) - Slow GUI performance while viewing Array LUN tab and Host Storage tab (e2853118) ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the HotFix --------------------------------------------------------------------------- 1. Apply the HotFix (VRTSccs-F520032962652) on 5.2RU3 CommandCentral Storage Management Servers having below hotfix installed - F520032819385 2. Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 3. Expected time taken by hotfix installation process is around 15 minutes. B - Deploying the patch 'VRTSccs-F520032962652.tar.gz' on Windows Management Server ------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win32-5.2RU3HF520032962652w-patches.zip to a temporary location. For example, to C:\Temp 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520032962652.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the CommandCentral HAL bin directory: "C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin" - Run the following command: perl LocalUpgrade.pl "C:\Temp\patches\VRTSccs-F520032962652.tar.gz" 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory. "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\ \VRTSccs-F520032962652\output" - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: For Windows: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520032962652 DATE=Thur Oct 18 15:11:34 2012 DESCRIPTION=CommandCentral Storage 5.2RU3 Management Server HotFix#6 REQUIREFIXES=F520032819385 OBSOLETES=F520032768725, F520032749322, F520032869371, F520032903493 C - Deploying the patch 'VRTSccs-F520032962652.tar.gz' on a Solaris Management Server ----------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy the file ccs-sol_sparc-5.2RU3HF520032962652u-patches.tar.gz to a temporary location. For example, to /tmp and unpack it. 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520032962652.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the HAL bin directory: /opt/VRTSccs/VRTShal/bin - Type the following command: ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F520032962652.tar.gz 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory: /var/VRTSccs/data/VRTShal/maint/VRTSccs-F520032962652/output - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open the cc_version.txt file from the following directory: For Windows hosts: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX hosts: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520032962652 DATE=Thur Oct 18 15:11:34 2012 DESCRIPTION=CommandCentral Storage 5.2RU3 Management Server HotFix#6 REQUIREFIXES=F520032819385 OBSOLETES=F520032768725, F520032749322, F520032869371, F520032903493 Additional Notes: ================== - Apply the HotFix (VRTSccs-F520032962652) on 5.2RU3 CommandCentral Storage Management Servers having below hotfix installed - F520032819385 - Expected time taken by hotfix installation process is around 15 minutes. - To get the complete fix for issue e2903493, below hotfix is also required to apply on Management Server and Control Hosts from where Hitachi arrays are configured - F520032930950