Date: 2013-Feb-06 OS: Solaris, Windows Etrack Incidents: 3024393, 3038057, 2962652, 2896795, 3052739, 2932101, 2965962, 2957824 Errors/Problems Fixed:[ - Incorrect Capacity Graph under Oracle Tablespace Projection report (e3024393) - Host Summary View page takes long time to load (e3038057) - HALCHM takes long time to process Data Collection Tasks (DCTs) of Arrays Explorers (e2962652) - Incorrect Switch connectivity information under HostConnectivity and ArrayConnectivity tabs(e2896795) - Unnecessary error messages are being logged in VxAM DB log table (e3052739) - Number of active Data Collection Tasks (DCTs) are decreasing with time (e2932101) - Storage Array LUN page takes long time to load(e2965962) - Some LUNs appear to be in the wrong Disk Groups (e2957824) ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the HotFix --------------------------------------------------------------------------- 1. Apply the HotFix (VRTSccs-F520043074324) on 5.2RU4 CommandCentral Storage Management Servers only. 2. Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 3. Expected time taken by hotfix installation process is around 15 minutes. B - Deploying the patch 'VRTSccs-F520043074324.tar.gz' on Windows Management Server ------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win32-5.2RU4HF520043074324w-patches.zip to a temporary location. For example, to C:\Temp 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520043074324.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the CommandCentral HAL bin directory: "C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin" - Run the following command: perl LocalUpgrade.pl "C:\Temp\patches\VRTSccs-F520043074324.tar.gz" 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory. "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\ \VRTSccs-F520043074324\output" - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: For Windows: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520043074324 DATE=Wed Feb 06 15:11:34 2013 DESCRIPTION=CommandCentral Storage 5.2RU4 Management Server Hotfix#1 - Re-packaged OBSOLETES=F520043024393 C - Deploying the patch 'VRTSccs-F520043074324.tar.gz' on a Solaris Management Server ----------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy the file ccs-sol_sparc-5.2RU4HF520043074324u-patches.tar.gz to a temporary location. For example, to /tmp and unpack it. 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520043074324.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the HAL bin directory: /opt/VRTSccs/VRTShal/bin - Type the following command: ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F520043074324.tar.gz 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory: /var/VRTSccs/data/VRTShal/maint/VRTSccs-F520043074324/output - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open the cc_version.txt file from the following directory: For Windows hosts: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX hosts: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520043074324 DATE=Wed Feb 06 15:11:34 2013 DESCRIPTION=CommandCentral Storage 5.2RU4 Management Server Hotfix#1 - Re-packaged OBSOLETES=F520043024393 Additional Notes: ================== - Apply the HotFix (VRTSccs-F520043074324) on 5.2RU4 CommandCentral Storage Management Servers only. - Expected time taken by hotfix installation process is around 15 minutes.