Date: 2014-06-02 OS: Windows, Linux Etrack Incidents: 3430061 Errors/Problems Fixed: 3430061 - Size of a folder includes size of its immediate deleted files. Applies to: Data Insight Management Server node and all Indexer nodes. Install/Uninstall Instructions: Apply this hotfix to Data Insight Management Server node and all Indexer nodes. This hotfix can be applied to Data Insight version 4.0 RP2 only. FILE AFFECTED BY THIS PATCH: Windows: INSTALL_ROOT\DataInsight\bin\mindexer.dll INSTALL_ROOT\DataInsight\bin\mxutil.dll INSTALL_ROOT\DataInsight\bin\idxwriter.exe INSTALL_ROOT\DataInsight\pdb\mindexer.pdb INSTALL_ROOT\DataInsight\pdb\mxutil.pdb INSTALL_ROOT\DataInsight\pdb\idxwriter.pdb Linux: INSTALL_ROOT/bin/idxwriter INSTALL_ROOT/lib/libmindexer.so INSTALL_ROOT/lib/libmxutil.so By default, value of INSTALL_ROOT on Windows is "C:\Program Files\Symantec". value of INSTALL_ROOT on Linux is "/opt". NOTE: Please keep a backup of the files you are about to patch. This will be required in case you want to rollback the patch. Steps: Log into Data Insight Management Server and Indexer nodes and perform the following steps: 1. Stop Data Insight services: For Windows : From the command prompt, issue the following command: net stop DataInsightWatchdog net stop DataInsightWeb net stop DataInsightHttpd net stop DataInsightComm net stop DataInsightConfig For Linux : From the command prompt, issue the following command: service DataInsightWatchdog stop service DataInsightComm stop service DataInsightConfig stop 2. Backup earlier files: For Windows : Take backup of entire bin and pdb folders under the install location. For Linux : Take backup of entire bin and lib folders under the install location. 3. Unzip the patch files to a temporary folder. In this folder, locate the "Patches" folder. This folder contains binaries for 64bit Windows operating System and Linux operating system. Files provided in the patch are in the same directory hierarchy as those present on your system at: "INSTALL_ROOT\DataInsight". Example: If you unzip hotfix to C:\temp, it will create the following folders under C:\temp: C:\TEMP\ +---README +---patches +---linux +---64bit +-------bin +-------lib +---windows +---32bit +-------bin +-------pdb +---64bit +-------bin +-------pdb 4. Copy the patch files to the install directory. For example, if you are patching a 64 bit Windows server installed at "C:\Program Files\Symantec\DataInsight", copy entire contents under "C:\temp\patches\windows\64bit" to "C:\Program Files\Symantec\DataInsight", replacing the original files with those from the patch. For linux, simply copy the contents of 64bit\lib folder to INSTALL_ROOT/DataInsight/bin folder and 64bit\bin folder to INSTALL_ROOT/DataInsight/lib folder 5. Start Data Insight services: For Windows: From the command prompt, issue the following command: net start DataInsightConfig net start DataInsightComm net start DataInsightHttpd net start DataInsightWeb net start DataInsightWatchdog For Linux: From the command prompt, issue the following command: service DataInsightConfig start service DataInsightComm start service DataInsightWatchdog start Additional Notes: 1. Apply this hotfix to Data Insight 4.0 RP2 only.