Installation options | Required disk space |
InfoScale Availability | 832 MB |
Release Date(GA) | Extended Support Starts | Sustaining Support Starts | End of Support Life Date(EOSL) |
---|---|---|---|
2020-06-01 | 2025-06-01 | 2027-06-01 | - |
Edition | Version | Notes |
---|---|---|
Windows Server 2016 Standard, Datacenter and Storage Edition | GA | The support for Windows 2016 includes Server Core versions. Note that client components cannot be installed on Server Core systems. |
Edition | Version |
---|---|
Windows Server 2016 Essentials Edition | GA |
OS | HBA model | iSCSI software initiator version |
---|---|---|
Microsoft Windows | Microsoft iSCSI Software Initiator [1] | 2.07 or above |
Documentation |
Array | Mode | Interface | Note |
---|---|---|---|
Celerra series | A/A-A | Fibre Channel | |
Celerra series | A/P-C | Fibre Channel | |
CLARiiON AX series | A/A-A | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/A-A | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/A-A | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/A-A | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/P-C | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/P-C | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/P-C | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/P-C | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON CX4 series | A/A-A | Fibre Channel | |
CLARiiON CX4 series | A/A-A | iSCSI | |
CLARiiON CX4 series with PowerPath | A/A-A | iSCSI | |
CLARiiON CX4 series | A/P-C | Fibre Channel | |
CLARiiON CX4 series | A/P-C | iSCSI | |
CLARiiON CX4 series with PowerPath | A/P-C | Fibre Channel | |
CLARiiON CX4 series with PowerPath | A/P-C | iSCSI | |
EqualLogic PS5000 series | A/A | iSCSI | * There is a known problem of IO hang sometimes when a NIC port is disabled on the Switch. Also, it is recommended to use 2 NICs for private heartbeat and a separate NIC for public-mix use or client-only use in MSCS environments due to a known issue when Private NICs are used for private heartbeat and other types of traffic. |
EqualLogic PS6000 series | A/A | iSCSI | |
PowerMax series | A/A | Fibre Channel | * PowerMax with PowerPath is supported |
PowerStore series | A/A-A | Fibre Channel | * Dell EMC PowerStore Array Thin Provisioning does not work with InfoScale for Windows. Please refer technote for more details https://www.veritas.com/content/support/en_US/article.100059084 |
PowerVault MD32xx Series | A/P-C | iSCSI | |
PowerVault MD32xx Series | A/P-C | SAS | |
PowerVault MD36xx Series | A/P-C | Fibre Channel | |
PowerVault MD36xx Series | A/P-C | iSCSI | |
PowerVault MD38xx Series | A/P-C | Fibre Channel | * Support for this array model is available from InfoScale release 7.2 and later. |
SC Series | A/A | Fibre Channel | * Supports Storage Center OS (SCOS) software version 6.2.2 and higher. |
SC Series | A/A | iSCSI | * Supports Storage Center OS (SCOS) software version 6.2.2 and higher. |
ScaleIO | A/A | Ethernet | |
Symmetrix DMX series | A/A | Fibre Channel | * Requires firmware version 5670.73 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * Supports Symmetrix DMX-3 and Symmetrix DMX-4 only. |
Symmetrix DMX series with PowerPath | A/A | Fibre Channel | * Supports Symmetrix DMX-3 and Symmetrix DMX-4 only. |
Symmetrix VMAX series | A/A | FCoE | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series | A/A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series with PowerPath | A/A | Fibre Channel | |
Unity series | A/A-A | Fibre Channel | |
Unity series with PowerPath | A/A-A | Fibre Channel | |
Unity XT series | A/A-A | Fibre Channel | |
Unity XT series | A/A-A | iSCSI | |
VMAX3/VMAX All Flash Family series | A/A | Fibre Channel | |
VMAX3/VMAX All Flash Family series with PowerPath | A/A | Fibre Channel | |
VNX series | A/A-A | Fibre Channel | * Supported with block mode storage only. |
VNX series | A/A-A | iSCSI | * Supported with block mode storage only. |
VNX series with PowerPath | A/A-A | Fibre Channel | |
VNX series | A/P-C | Fibre Channel | * Supported with block mode storage only. |
VNX series | A/P-C | iSCSI | * Supported with block mode storage only. |
VNX series with PowerPath | A/P-C | Fibre Channel | |
VNX2 series | A/A-A | Fibre Channel | * Supported with block mode storage only. |
VNX2 series with PowerPath | A/A-A | Fibre Channel | |
VPLEX | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
VPLEX with PowerPath | A/A | Fibre Channel | |
XtremIO | A/A | FCoE | |
XtremIO | A/A | Fibre Channel | |
XtremIO | A/A | iSCSI |
Array | Mode | Interface | Note |
---|---|---|---|
ETERNUS DX400/DX500/DX600 series | A/A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX400/DX500/DX600 series | A/A-A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX60/DX80/DX90/DX100/DX200 series | A/A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90. |
ETERNUS DX60/DX80/DX90/DX100/DX200 series | A/A-A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90. |
ETERNUS DX8000 S3/S4 series | A/A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 S3/S4 series | A/A-A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 series | A/A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 series | A/A-A | Fibre Channel | * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS VS850 | A/A-A | Fibre Channel | |
ETERNUS VS850 with Subsystem Device Driver | A/A-A | Fibre Channel | |
ETERNUS2000 series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
ETERNUS4000 series | A/A | Fibre Channel | * Excludes ETERNUS4000 models 80 and 100. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS8000 series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
Array | Mode | Interface | Note |
---|---|---|---|
3PAR F/T-Class, StoreServ 7000/8000/9000/10000/20000 Storage | A/A | Fibre Channel | * 3PAR F/T-Class maximum firmware version is 3.1.3; 3PAR StoreServ 7000/10000 minimum firmware version 3.1.2 and StoreServ 8000/20000 minimum firmware version 3.2.2 are required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * StoreServ 8000/20000 minimum firmware version 3.2.2 MU1 is required for Thin Reclamation support. |
Alletra 5000 Series | A/A-A | Fibre Channel | |
Alletra 6000 Series | A/A-A | Fibre Channel | |
Alletra 9000 Storage | A/A | Fibre Channel | |
MSA 1040 SAN | A/A-A | Fibre Channel | |
MSA 1060 Storage | A/A-A | Fibre Channel | |
MSA 2040 SAN | A/A-A | Fibre Channel | |
MSA 2040 SAN | A/A-A | iSCSI | |
MSA 2040 SAN | A/A-A | SAS | |
MSA 2050 Storage | A/A | Fibre Channel | |
MSA 2060 Storage | A/A-A | Fibre Channel | |
MSA P2000 | A/A-A | Fibre Channel | |
MSA1000 | A/A | Fibre Channel | |
MSA1500 | A/A | Fibre Channel | * Active/Active array firmware is required. Contact your local HP representative for more information. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2000fc series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2012i | A/A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2012sa | A/A | SAS | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2212i | A/A | iSCSI | |
MSA2212sa | A/A | SAS | |
P9500 | A/A | Fibre Channel | * Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Primera 600 Storage | A/A | Fibre Channel | |
XP7 series | A/A | Fibre Channel | |
XP8 series | A/A | Fibre Channel | |
XP8 series | A/A-A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
HUS 100 series | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix |
HUS 100 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
HUS VM | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix |
HUS VM with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
SMS/AMS2000 series | A/A | Fibre Channel | * Excludes SMS100. * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix * SMS does not support Thin Provisioning. |
SMS/AMS2000 series | A/A | iSCSI | * Excludes SMS100. * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix * SMS does not support Thin Provisioning. |
SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | * Excludes SMS100. |
SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager) | A/A | iSCSI | * Excludes SMS100. |
USPV/USPVM | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix |
USPV/USPVM with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix * Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
VSP with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP 5000 series | A/A | Fibre Channel | |
VSP E series | A/A | Fibre Channel | |
VSP G series | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix |
VSP G series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP Gx00/Fx00 series | A/A | Fibre Channel | * For EOSL Storage Systems, Please refer Hitachi Vantara Product Life-Cycle Matrix - https://knowledge.hitachivantara.com/Support_Information/More_Info/Product_Life-Cycle_Matrix |
Array | Mode | Interface | Note |
---|---|---|---|
18000 series | A/A | Fibre Channel | * For Huawei 18000 A/A, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. |
OceanStor Series | A/A-A | Fibre Channel | * For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported. |
OceanStor Series | A/A-A | iSCSI | * For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported. |
S5000 series | A/P-C | Fibre Channel | |
VIS series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
DS3950 | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
DS3950 with DS Storage Manager | A/P-C | Fibre Channel | |
DS5020 | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
DS5020 with DS Storage Manager | A/P-C | Fibre Channel | |
FlashSystem series | A/A | Fibre Channel | * Supports FlashSystem 840/900 models only. |
Spectrum Virtualize series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Spectrum Virtualize series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Spectrum Virtualize series with Subsystem Device Driver | A/A-A | Fibre Channel | |
Storwize series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Storwize series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Storwize series with Subsystem Device Driver | A/A-A | Fibre Channel | |
System Storage DS3000 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3000 series | A/P-C | iSCSI | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3000 series | A/P-C | SAS | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | iSCSI | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | SAS | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS5000 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS5000 series with DS Storage Manager | A/P-C | Fibre Channel | |
System Storage DS8000 series | A/A | Fibre Channel | * Requires firmware version 6.1.600.46 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS8000 series with Subsystem Device Driver | A/A | Fibre Channel | |
System Storage N series | A/A-A | Fibre Channel | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/A-A | iSCSI | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/P-C | Fibre Channel | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/P-C | iSCSI | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage XIV series | A/A | Fibre Channel | * To obtain Clustering support with IBM XIV, a minimum Firmware level of 10.0.1.c is required. |
Array | Mode | Interface | Note |
---|---|---|---|
Nexsan E-Series Systems | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
InfiniBox F-Series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
DC P3700 | A/A | PCIe | |
SSD 910 | A/A | PCIe |
Array | Mode | Interface | Note |
---|---|---|---|
K2 | A/A | Fibre Channel | * Support for this array model is available from InfoScale release 7.3.1 and later. |
Array | Mode | Interface | Note |
---|---|---|---|
MS series | A/A-A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
Azure | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
AFF Series | A/A-A | Fibre Channel | * A minimum version of ONTAP 8.3 is required to support this array. |
AFF Series | A/A-A | iSCSI | * A minimum version of ONTAP 8.3 is required to support this array. |
E_SERIES | A/A-A | Fibre Channel | |
FAS2000/FAS900/FAS200 series | A/A-A | Fibre Channel | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS2000/FAS900/FAS200 series | A/A-A | iSCSI | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS2000/FAS900/FAS200 series | A/P-C | Fibre Channel | |
FAS2000/FAS900/FAS200 series | A/P-C | iSCSI | |
FAS3000/V3000 series | A/A-A | Fibre Channel | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS3000/V3000 series | A/A-A | iSCSI | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS3000/V3000 series | A/P-C | Fibre Channel | |
FAS3000/V3000 series | A/P-C | iSCSI | |
FAS6000/V6000 series | A/A-A | Fibre Channel | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS6000/V6000 series | A/A-A | iSCSI | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS6000/V6000 series | A/P-C | Fibre Channel | |
FAS6000/V6000 series | A/P-C | iSCSI | |
FAS8000/FAS9000 Series | A/A-A | Fibre Channel | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS8000/FAS9000 Series | A/A-A | iSCSI | * Supports Clustered Data ONTAP (cDOT) version 8.2.1 or greater with multiple Controller Nodes. |
FAS8000/FAS9000 Series | A/P-C | Fibre Channel | |
FAS8000/FAS9000 Series | A/P-C | iSCSI |
Array | Mode | Interface | Note |
---|---|---|---|
NexentaStor | A/A-A | Fibre Channel | * Support for this array model is available from InfoScale release 7.3.1 and later. |
Array | Mode | Interface | Note |
---|---|---|---|
Beast Systems | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
CS/AF/HF-Series | A/P-C | Fibre Channel | * Support for this array model is available from InfoScale release 7.3.1 and later. |
Array | Mode | Interface | Note |
---|---|---|---|
Axiom series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
FS1-2 | A/A-A | Fibre Channel | * Support for this array model is available from InfoScale release 7.2 and later. |
Storage 6580/6780 series | A/P-C | Fibre Channel | |
StorageTek 2500 series | A/P-C | Fibre Channel | |
StorageTek 2500 series | A/P-C | iSCSI | |
StorageTek 2500 series | A/P-C | SAS | |
StorageTek 6140 array | A/P-C | Fibre Channel | |
StorageTek 9900 series | A/A | Fibre Channel | |
StorageTek 9900 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9985/9990 series | A/A | Fibre Channel | |
StorageTek 9985/9990 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9985V system | A/A | Fibre Channel | |
StorageTek 9985V system with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9990V system | A/A | Fibre Channel | |
StorageTek 9990V system with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
Sun Storage 6180 array | A/P-C | Fibre Channel | |
ZFS Storage Appliance series | A/A-A | Fibre Channel | * Excludes ZFS Storage ZS4-4. |
ZFS Storage Appliance series | A/A-A | iSCSI | * Excludes ZFS Storage ZS4-4. |
Array | Mode | Interface | Note |
---|---|---|---|
FlashArray series | A/A | Fibre Channel | |
FlashArray series | A/A-A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
ioDrive | A/A | PCIe | |
ioDrive2 | A/A | PCIe | |
ioMemory PX600 series | A/A | PCIe | |
ioMemory SX300 series | A/A | PCIe |
Array | Mode | Interface | Note |
---|---|---|---|
FlexLine 200/300 series | A/P-C | Fibre Channel | * Support for the StorageTek Flexline 300 series Storage Systems includes the FLX380 array only. |
Array | Mode | Interface | Note |
---|---|---|---|
StorageTek 6130 | A/P-C | Fibre Channel | * The Sun StorEdge 6130 array requires additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use the Sun StorEdge 6130 array with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP. Specific firmware levels from the manufacturer for these arrays may also be required. |
StorageTek 6540 | A/P-C | Fibre Channel | |
StorEdge 9910/9960 | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
StorEdge 9910/9960 with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
Violin 3000/6000 series | A/A | Fibre Channel | |
Violin 3000/6000 series | A/A-A | Fibre Channel | * A minimum array firmware version G5.5.1 is required to support ALUA mode. |