V-11-1-1
Severity: Critical 
Component: Cluster Server 
Message:
Unable to register with coordinator disk with serial number: %s
Description:

When a node tries to join a cluster that uses SCSI-3 based I/O fencing, the VxFEN driver on the joiner node attempts to register with a majority of the coordinator disks. If the SCSI-3 registration fails for a coordinator disk, this message is displayed on the console. If the registration fails for majority of disks, the node cannot join the cluster.

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2012-08-08 01:14:37
Platform: Generic
Release: Generic
Content:

The administrator should check the coordinator disks for SCSI-3 support.


For information on VxFEN driver error messages, see:
 

https://sort.veritas.com/public/documents/sf/5.0/solaris64/html/sf_rac_install/sfrac_error_messages5.html