Error Code details
V-16-13-4258
Severity: n/a 
Component: Cluster Server 
Message:
There was an error reading the registry

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2009-11-10 06:00:12
Platform: Generic
Release: Generic
Content:

Description

This error appears when there are inconsistencies between the nodes for the values contained under the following registry key:

HKLM\Software\Veritas\VCS\Exchconfig\EVS\%evsname%\systems\%systemname%

Values found under this key include:

InitiatorName - This can be left blank.
MACAddress - Contains the MAC address of primary NIC.
VCSName - Cointains the name of the physical node.


Solution

Ensure that the values contain correct information on all nodes.

WARNING: Incorrect use of the Windows Registry Editor can have disastrous results on a server operating system. Great care should be taken when making changes to a Windows Registry. Registry modifications should only be carried out by persons experienced in the use of the Registry Editor application.


Other Notes

The following errors may also appear under ExchInstaller_A.txt:

VCS ERROR V-16-13-10016 Windows API RegQueryValueEx failed with error code 2. ./LibRegistry.cpp:CLibRegistry::ReadRegistryDWORDValue[0724]
VCS ERROR V-16-13-10016 Windows API RegQueryValueEx failed with error code 2. ./LibRegistry.cpp:CLibRegistry::ReadRegistryDWORDValue[0724]
VCS ERROR V-16-13-10016 Windows API RegQueryValueEx failed with error code 2. ./LibRegistry.cpp:CLibRegistry::ReadRegistryStringValue[0564]
VCS ERROR V-16-13-10016 Windows API RegQueryValueEx failed with error code 2. ./LibRegistry.cpp:CLibRegistry::ReadRegistryStringValue[0564]
VCS ERROR V-16-13-10005 Call to function CLibRegistry::ReadRegistryStringValue() failed. Error Type = 2 Error Code = 2 ./ExchRegistry.cpp:CExchRegistry::ReadVCSExchReg[0571]
VCS ERROR V-16-13-10005 Call to function CExchRegistry::ReadVCSExchReg() failed. Error T

 

Reference: http://entsupport.symantec.com/docs/292364