Error Code details
V-16-20018-9
Severity: n/a 
Component: Cluster Server 
Message:
Monitor procedure %s did not exit. Return value is %s

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2008-12-04 10:07:21
Platform: Generic
Release: Generic
Content:
Description: The in-depth monitor procedure specified using the [Monscript] attribute did not exit. The return code is as reported by the waitpid() system call for the execution of in-depth monitor script. For additional information, refer to man page for waitpid() system call.

Recommended Action: Verify for correctness, the in-depth monitor procedure specified using [Monscript] attribute. Fix the in-depth monitor procedure and ensure that it exits with correct value as understood by the VCS agent framework. Refer to the Veritas Cluster Server Agent Developer's Guide for possible values that a script based monitor entry point (agent function) can return.