Error Code details
V-5-0-166
Severity: Warning 
Component: Volume Manager 
Message:
Failed to log the detach of the DRL volume

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2008-12-04 10:07:56
Platform: Generic
Release: Generic
Content:
An attempt failed to write a kernel log entry indicating the loss of a DRL volume. The attempted write to the log failed either because the kernel log is full, or because of a write error to the drive. The volume becomes detached.

Messages about log failures are usually fatal, unless the problem is transient. However, the kernel log is sufficiently redundant that such errors are unlikely to occur.

If the problem is not transient (that is, the drive cannot be fixed and brought back online without data loss), recreate the disk group from scratch and restore all of its volumes from backups. Even if the problem is transient, reboot the system after correcting the problem.

If error messages are seen from the disk driver, it is likely that the last copy of the log failed due to a disk error. Replace the failed drive in the disk group. The log re-initializes on the new drive. Finally force the failed volume into an active state and recover the data.