Error Code details
V-5-0-249
Severity: Warning 
Component: Volume Manager 
Message:
RAID-5 volume entering degraded mode operation

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2008-12-04 10:07:56
Platform: Generic
Release: Generic
Content:
An uncorrectable error has forced a subdisk to detach. At this point, not all data disks exist to provide the data upon request. Instead, parity regions are used to regenerate the data for each stripe in the array. Consequently, access takes longer and involves reading from all drives in the stripe.

Check for other console error messages that indicate the cause of the failure. Replace any failed disks as soon as possible.