Error Code details
V-5-1-18706
Severity: Error 
Component: Volume Manager 
Message:
Failed to associate atomic-write capable volume %s with atomic-write capable volume set %s due to mismatch in atomic-write iosize
Description:
'Every atomic-write volume has default atomic-write iosize. An atomic-write capable volume being added to atomic-write capable vset should have atomic-write iosize same as that of volumes in that vset, otherwise operation would fail with above mentioned error.'

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2014-11-27 10:57:19
Platform: Red Hat Enterprise Linux 6 (x86-64)
Release: 6.2
Content:
Ensure that the atomic-write iosize of the atomic-write capable volume being added is the same as that of the volumes in the atomic-write capable vset.