Error Code details
V-52410-33081-72
Severity: n/a 
Component: Cluster Server 
Message:
The fire drill setup is in an inconsistent state. Please choose the delete option for clean up.

 

Veritas solutions
Solution 1 Vote: [Useful] [Not useful]
Last Modified: 2009-11-10 05:27:01
Platform: Generic
Release: Generic
Content:

V-52410-33081-72 - The fire drill setup is in an inconsistent state. Please choose the delete option for clean up.

Possible causes

This error is typically seen when the fire drill service group is in some undesired state.
This could occur as follows:
 

    You use the Fire Drill Wizard to configure a fire drill service group (the ?Prepare? step of the fire drill configuration).
    After this some changes are made to the fire drill service group manually or externally (that is, not by the Fire Drill Wizard). For example, the plex name is changed. These changes do not get registered by the wizard.
    As a result the Fire Drill Wizard configuration data and the actual configuration are different. Because of this mismatch the wizard is unable to perform any operations on the fire drill service group. Otherwise, if the wizard continued, further misconfiguration and failed steps could occur.
    Therefore, the Fire Drill Wizard displays this message to prompt you to delete the existing fire drill service group.
    After deleting this inconsistent fire drill service group, you can run the wizard again to create a fresh new fire drill configuration.


Solution

The following actions may apply:

After deleting the fire drill configuration, snap abort the fire drill plexes manually (if the Fire Drill Wizard has failed to do so) to recover the disk space used during the fire drill process.
After deleting the fire drill configuration, re-launch the Fire Drill wizard to create a fresh new fire drill configuration.
 

    Reference: http://entsupport.symantec.com/docs/306761