Symptoms
-
Status code V-76-58631-24 is reported by Veritas Enterprise Administrator (VEA)
-
ERROR: "This partition was created but the volume never arrived, it may arrive later, but for now the partition is unusable"
Description
This message appears if the host bus adapter (HBA) topology has been incorrectly configured. If Veritas multipathing drivers are present, set the HBA topology to 1. This recommendation assumes that the HBA topology options are the following:
0 = Loop
1 = F_Port (Point-to-point) Fabric
2 = Loop then F_Port (Point-to-point)
3 = F_Port (Point-to-point) then Loop
Note:
Contact Emulex for further information about Emulex topology settings.
The error may occur if the configuration does not match the Hardware Compatibility List (HCL) for Veritas Storage Foundation for Windows. Review the HCL to verify that the drivers and hardware are compatible with Veritas Storage Foundation for Windows:
www.symantec.com/docs/TECH148533
To provide our customers with as many troubleshooting resources as possible, Veritas Enterprise Technical Support is currently working to research and provide information for all possible status codes and errors that may appear while using Veritas Storage Foundation for Windows. An explanation, work-around, or solution for each status code will be added once this information has been developed. This is an on-going process.
If you have received this status code and require assistance, contact Veritas Enterprise Technical Support:
Telephone list:
http://www.symantec.com/business/support/index.jsp