vm-hpux1131-5.0_GA_RP1_2008-08-08
Obsolete
The latest patch(es) : vm-hpux1131-5.0MP1P7 

 Basic information
Release type: Rolling Patch
Release date: 2008-08-08
OS update support: None
Technote: None
Documentation: None
Popularity: 1067 viewed    downloaded
Download size: 53.44 MB
Checksum: 2150829220

 Applies to one or more of the following products:
Storage Foundation 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation Cluster File System 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation for Oracle 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation for Oracle RAC 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation HA 5.0 On HP-UX 11i v3 (11.31)
Volume Manager 5.0 On HP-UX 11i v3 (11.31)
Volume Replicator 5.0 On HP-UX 11i v3 (11.31)

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch is obsolete. It is superseded by: Release date
vm-hpux1131-5.0MP1P4 (obsolete) 2011-09-05
vm-hpux1131-5.0MP1P3 (obsolete) 2011-05-23
vm-hpux1131-5.0MP1P1 (obsolete) 2010-09-16
sfha-hpux1131-5.0MP1 2010-07-14
vm-hpux1131-5.0GARP8 (obsolete) 2010-06-22
vm-hpux1131-5.0GARP6 (obsolete) 2009-11-17
vm-hpux1131-5.0GARP5 (obsolete) 2009-10-06
vm-hpux1131-5.0GARP3 (obsolete) 2009-05-03
vm-hpux1131-5.0GARP2 (obsolete) 2008-11-11

 Fixes the following incidents:
1248457, 1248473, 1248476, 1249375, 1254892, 1267621, 1268742, 1271809, 1281703

 Patch ID:
PHCO_38235
PHKL_38236

Readme file
Date: 2008-08-08
OS: HP-UX
OS Version: 11.31
Packages:
Etrack Incidents: 1248457, 1248473, 1248476, 1249375, 1254892, 1267621, 1268742, 1271809, 1281703
Errors/Problems Fixed:
e1248457 [QXCR1000785683]: vxconfigd cores generated after a 48h ST was run with bundle 7
e1248473 [QXCR1000768134]: 0107Drop: Uncorrectable read , write errors during c8 + rand_mpath
e1248476 [QXCR1000769903]: 0107Drop: Errors during VxVM Stress test on EMC devices
e1249375 [QXCR1000797373]ERROR: dump device 3:0x1 cannot be used and will be ignored: unsupported
e1254892 Vxdiskadm option 18:2 in not working to include perticular path again in vxvm view.
e1267621 Failover is not happening on PA machine using vxdmpadm enable disable path command and also the vxdmpadm enable command hung.
e1268742 Failback is not happening when all primary paths are again made active.
e1271809 vxconfigd dumped core on master node after doing failover from master with vxfencing enable.
e1281703 I/O continues to go via standby path even though an active primary path was enabled.

Fixes Applied for Products:
Volume Manager

Install/Uninstall Instructions:
1. Remove all  the UnOfficial patches before installing patch.
2. Install these patches using:

	$ swinstall -x autoreboot=true -s <patch location> PHCO_38235 PHKL_38236

3. Please do swverify after installing the patches in order to make sure
   that the patches are installed correctly using:

	$ swverify  PHCO_38235 PHKL_38236

4. Uninstall the patches using:

	$ swremove -x autoreboot=true  PHCO_38235 PHKL_38236

Additional Notes:
The Patches PHCO_38235 & PHKL_38236 can be installed only
on a system with 5.0 HP 11.31 5.0.31.1 Base-VxVM installed.