This page lists publically-released patches for Veritas Enterprise Products.
For Product GA build, see Veritas Entitlement Management System(VEMS) by clicking the Veritas Support 'Licensing' option.
For information on private patches, contact Veritas Technical Support.
Veritas is making it easier to find all software installers and updates for Veritas products with a completely redesigned experience. NetBackup HotFixes and NetBackup Appliance patches are now also available at the new Veritas Download Center.
Patches for your product can have a variety of names. These names are based on product, component, or package names. For more information on patch naming conventions and the relationship between products, components, and packages, see the SORT online help.
vm-hpux1131-4.1_GA_RP2_2008-08-08
Obsolete
The latest patch(es) : vm-hpux1131-4.1GARP4 
Sign in if you want to rate this patch.

 Basic information
Release type: Rolling Patch
Release date: 2008-08-08
OS update support: None
Technote: None
Documentation: None
Popularity: 515 viewed    4 downloaded
Download size: 42.48 MB
Checksum: 3494803588

 Applies to one or more of the following products:
Volume Manager 4.1 On HP-UX 11i v3 (11.31)

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch is obsolete. It is superseded by: Release date
vm-hpux1131-4.1GARP4 2009-12-21
vm-hpux1131-4.1GARP3 (obsolete) 2008-11-13

 Fixes the following incidents:
1023851, 1035585, 1089882, 1099736, 1099843, 1099854, 1099874, 1099883, 1184944, 1197978, 1221322

 Patch ID:
PHCO_37836
PHKL_37929

 Readme file  [Save As...]
Date: 2008-08-07 
OS: HP-UX 
OS Version: 11.31
Packages: 
Etrack Incidents: 1221322, 1035585, 1089882, 1099736, 1099843, 1099854, 1099874, 1099883, 1197978, 1023851, 1184944
Errors/Problems Fixed:

Double free of memory in voldg_clean_cpulist()(e1023851)
210-047-678 / HP-for Lucent / VxVM 4.1 will miscalculate the capacity of a disk (e1035585)
Increasing vol_maxio, vol_maxspecialio, and MAXIOSIZE to 1 MB on HP-UX (e1089882)
Adding support passive path - Adding VF_OID_DUMMY flag (e1099736)
Escalation: Storage Extensions doesn't work - VM plugin of VxMS tries to claim "/" (e1099843)
Escalation: Titan Case 290-543-757 -"Storage Extensions doesn't work" - dg_set_current fails for bootdg (e1099854)
VM plugin of VxMS fails to initialise the private data of log plex and it results in buildmapdomain to fail ?(e1099874)
Escalation: Memory Leak in VM & DMP plugin of VxMS (e1099883)
VRTSvxvm.VXVM-KRN preremove script error (e1184944)
Root mirroring fails for non-system volumes on rootdisk, with Lite/No license (e1197978)
modify VxVM code to check for "LVMREC" instead of "LVMREC01" (e1221322)

Fixes Applied for Products:
Volume Manager

Install/Uninstall Instructions:

1) To Install the patch

swinstall -x autoreboot=true -s <patch-location> PHCO_37836 PHKL_37929

2) To Verify that patches are installed

swlist | grep PHKL_37836
swlist | grep PHCO_37929

3) To check the errors in the installation

swverify PHCO_37836 PHKL_37929

4) To remove the patches

swremove -x autoreboot=true PHKL_37929 PHCO_37836

Additional Notes:



Read and accept Terms of Service