data_insight-win64-5.2.2HF1

 Basic information
Release type: Hot Fix
Release date: 2017-07-12
OS update support: None
Technote: None
Documentation: None
Popularity: 405 viewed    downloaded
Download size: 16.69 MB
Checksum: 2850073022

 Applies to one or more of the following products:
Data Insight 5.2 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
3923919

 Patch ID:
None.

Readme file
Date: 2017-07-12

OS: Windows

Etrack Incidents: 3923919

Errors/Problems Fixed:

3923919 - (JIRA ID: CFT-431) CVE-2017-5638 vulnerability for Data Insight 5.2
 
Applies to: Data Insight Management Server node and Portal node.

Install/Uninstall Instructions:

Apply this hotfix to Data Insight Management Server node and Portal node only.

This hotfix can be applied to Data Insight version 5.2 RP2 only.

FILE AFFECTED BY THIS PATCH:

Windows:
INSTALL_ROOT\tomcat\webapps\symhelp\*
INSTALL_ROOT\portal_tomcat\webapps\symhelp\*

By default, value of INSTALL_ROOT on Windows is "C:\Program Files\DataInsight".

Steps:

Log into Data Insight Management Server node or Portal node and perform the following steps:
	
	1. Stop Data Insight services:
    	From the command prompt, issue the following commands:
		
        net stop DataInsightWatchdog
        net stop DataInsightWeb
	net stop DataInsightComm
        net stop DataInsightConfig
	
	2.  Unzip the patch files to a temporary folder. In this folder, locate the
	"patches" folder. This folder contains all files for help application.
	
	Example: If you unzip hotfix to C:\temp, it will create the following folder
	under C:\temp:
	C:\TEMP\
	+---README
	+---patches
		+---symhelp

	3. Delete affected files from Data Insight:
	Delete directories "INSTALL_ROOT\tomcat\webapps\symhelp" and "INSTALL_ROOT\portal_tomcat\webapps\symhelp".
	
	Example: if you are patching Management server installed at "C:\Program Files\DataInsight",
	delete direcories "C:\Program Files\DataInsight\tomcat\webapps\symhelp" and
	"C:\Program Files\DataInsight\portal_tomcat\webapps\symhelp".
	 	
	4.  Copy the patch files to the install directory.
	
	Example: if you are patching Management server installed at 
	"C:\Program Files\DataInsight", copy "symhelp" folder under 
	"C:\temp\patches" to "C:\Program Files\DataInsight\tomcat\webapps" and 
	"C:\Program Files\DataInsight\portal_tomcat\webapps\".

	5. Start Data Insight services:
	From the command prompt, issue the following commands:
	
        net start DataInsightConfig
        net start DataInsightComm
	net start DataInsightWeb
        net start DataInsightWatchdog
	
Additional Notes:
1. Apply this hotfix to Data Insight 5.2 RP2 only.