data_insight-win64-6.1HF1

 Basic information
Release type: Hot Fix
Release date: 2017-10-27
OS update support: None
Technote: None
Documentation: None
Popularity: 3838 viewed    downloaded
Download size: 110.64 KB
Checksum: 591229703

 Applies to one or more of the following products:
Data Insight 6.1 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
3931651

 Patch ID:
None.

Readme file
Date: 2017-10-26

OS: Windows

Etrack Incidents: 3931651

Errors/Problems Fixed:

3931651- (JIRA ID: CFT-621) Incremental scan fails with exit code 1 while consuming scan reconciliation database
 
Applies to: Data Insight Collector node and Windows File Server Node.

Install/Uninstall Instructions:

Apply this hotfix to Data Insight Collector and Windows File Server Nodes only.

This hotfix can be applied to Data Insight version 6.1 only.

FILE AFFECTED BY THIS PATCH:

Windows:
INSTALL_ROOT\bin\scanner.exe

By default, value of INSTALL_ROOT on Windows is "C:\Program Files\DataInsight".

Steps:

Log into Data Insight Collector Node or Windows Filer Server and perform the following steps:
	
	1. Stop Data Insight services:
    	From the command prompt, issue the following command:

	net stop DataInsightComm
	net stop DataInsightConfig
	net stop DataInsightWatchdog
	net stop DataInsightWorkflow
	
	2.  Unzip the patch files to a temporary folder. In this folder, locate the
	"patches" folder. This folder contains all files for help application.
	
	Example: If you unzip hotfix to C:\temp, it will create the following folder
	under C:\temp:
	C:\TEMP\
	+---README
	+---patches
		+---scanner.exe
      
	3.  Copy the patch files to the install directory.
	For example, if you are patching Collector Node installed at 
	"C:\Program Files\DataInsight", copy "scanner.exe" file under 
	"C:\temp\patches" to "C:\Program Files\DataInsight\bin"
	replacing the original files with those from the patch.
	
	4. Start Data Insight services:
	From the command prompt, issue the following command:
	
	net start DataInsightComm
	net start DataInsightConfig
	net start DataInsightWatchdog
	net start DataInsightWorkflow
	
Additional Notes:
1. Apply this hotfix to Data Insight 6.1 only.