vrp-centos69_x86_64-Patch-3.3.2.12

 Basic information
Release type: Patch
Release date: 2019-06-24
OS update support: None
Technote: None
Documentation: None
Popularity: 185 viewed    downloaded
Download size: 147.1 MB
Checksum: 3603573018

 Applies to one or more of the following products:
Resiliency Platform 3.3.2 On CentOS 6.9 x86-64

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
3979293

 Patch ID:
None.

Readme file
                          * * * READ ME * * *
                 * * * Veritas Resiliency Platform Hot Fix 12 (3.3.2.12) * * *                         
                         Hotfix Date: 2019-06-17


This document provides the following information:

   * HOTFIX NAME
   * APPLIANCES SUPPORTED BY THE HOTFIX
   * BASE PRODUCT VERSION FOR THE HOTFIX
   * SUMMARY OF ISSUES FIXED BY THE HOTFIX
   * DETAILS OF ISSUES FIXED BY THE HOTFIX
   * INSTALLING THE HOTFIX
   * KNOWN ISSUES
   * NOTE


HOTFIX NAME
----------
Veritas Resiliency Platform Hotfix 12 (3.3.2.12)

APPLIANCES SUPPORTED BY THE HOTFIX
----------------------------------------
Resiliency Manager

BASE PRODUCT VERSION FOR THE HOTFIX
-----------------------------------
Veritas Resiliency Platform 3.3.2


SUMMARY OF ISSUES FIXED BY THE HOTFIX
---------------------------------------
Hotfix 3.3.2.12:
* STESC-2718 (VRP-23979) - Create RG does not work when same vCenter added both Veritas Infoscale Operations Manager and Infrastructure Management Server of Veritas Resiliency Manager 

DETAILS OF ISSUES FIXED BY THE HOTFIX
--------------------------------------------
This hotfix fixes the following JIRA issues:

* STESC-2718 (Fix Tracking ID - VRP-23979)

SYMPTOM: Create RG does not work when same vCenter added both Veritas Infoscale Operations Manager and Infrastructure Management Server of Veritas Resiliency Manager 

DESCRIPTION: Discovery of vCenter information from VIOM and IMS is different and it was resulting in the data to be merged resulted in unexpected behavior

RESOLUTION: Fixed the issue to identify information coming from IMS vs VIOM which was causing this failure.

INSTALLING THE HOTFIX
--------------------
  1. Contact Veritas Technical Support for this Hot Fix and check if the hotfix is relevant to issue seen in your environment.
  2. Download the hotfix and copy it to any server having access to VRP appliances.
  3. Make sure there is no operation in progress while the hotfix is being applied.
  4. Perform the following steps to upload the hotfix
    a) Open the SFTP session from clish
	   utilities> sftp-session start put hotfix
	b) Provide the password for this temporary SFTP session
	c) Open SFTP session using the above created user information and upload the hotfix
  5. Perform the following steps to install the hotfix
    a) Verify that the hotfix is uploaded from clish
	   hotfix> list-available-hotfixes
	b) Apply the hotfix from clish
	   hotfix> apply-hotfix 3.3.2.12
  6. Verify hotfix is applied successfully from clish
     hotfix> list-applied-hotfixes
  7. Close the SFTP session opened earlier
     utilities> sftp-session stop
  8. Repeat the steps 4 to 7 for all the VRP RM appliances.
    

KNOWN ISSUES
-----------
None

NOTE
----
Make sure that hotfix 3.3.2.1 is installed before installing this hotfix.