vcs-hpux1123-VRTSvxfen-5.0MP1RP2HF1

 Basic information
Release type: Hot Fix
Release date: 2009-04-24
OS update support: None
Technote: 323682
Documentation: None
Popularity: 1230 viewed    downloaded
Download size: 658.64 KB
Checksum: 2859603985

 Applies to one or more of the following products:
Cluster Server 5.0 On HP-UX 11i v2 (11.23)
Cluster Server 5.0MP2 On HP-UX 11i v2 (11.23)
Storage Foundation Cluster File System 5.0 On HP-UX 11i v2 (11.23)
Storage Foundation Cluster File System 5.0MP2 On HP-UX 11i v2 (11.23)
Storage Foundation for Oracle 5.0 On HP-UX 11i v2 (11.23)
Storage Foundation for Oracle 5.0MP2 On HP-UX 11i v2 (11.23)
Storage Foundation for Oracle RAC 5.0 On HP-UX 11i v2 (11.23)
Storage Foundation for Oracle RAC 5.0MP2 On HP-UX 11i v2 (11.23)
Storage Foundation HA 5.0 On HP-UX 11i v2 (11.23)
Storage Foundation HA 5.0MP2 On HP-UX 11i v2 (11.23)

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch requires: Release date
5.0 MP1a 2007-05-29

 Fixes the following incidents:
1601623

 Patch ID:
UNOF_39781

Readme file
OS: HP-UX
OS Version: 11iv2
Etrack Incidents: 1601623
Fixes Applied for Products:
	VRTSvxfen - Veritas Fencing by Symantec 5.0MP1RP2
	VRTSvxfen - Veritas Fencing by Symantec 5.0MP2

Problem Description & Resolution:
    Description:
	"vxfenconfig -U" when run prints the following error:
	# vxfenconfig -U
	VXFEN vxfenconfig ERROR V-11-2-1064 DMP Idle Lun Monitoring DeRegistration FAILED
	VXFEN vxfenconfig ERROR V-11-2-1065 Error returned 0xffffffff
    Resolution:
	Removed the idle lun path probing code from vxfenconfig that was resulting the error message.

Before Installation: 
	Before installing this patch, please install either of the following patches on your cluster:
		VCS 5.0MP1RP2 patches for 11iv2
	    OR 
		VCS 5.0MP2 patches for 11iv2

Install/Removal Instructions:
	Please review all instructions and the Veritas support terms
	and conditions for precautions, scope of license,
	restrictions, and, limitation of liability and warranties,
	before installing this patch.

	Please review the instructions given in 
	"Veritas Cluster Server Release Notes for HP-UX for 5.0 Maintenance Pack 1 Rolling Patch 2"
	to install and configure VCS 5.0MP1RP2 on 11iv2.
	or 
	"Veritas Cluster Server Release Notes for HP-UX for 5.0 Maintenance Pack 2"
	to install and configure VCS 5.0MP2 on 11iv2.

Perform the following steps to install the VxFen UNOF Patch on the cluster:
To install the VxFen UNOF Patch
	1) Install/Upgrade all the cluster nodes to VCS 5.0MP1RP2 or 5.0MP2 on 11iv2.
		"Refer to the VCS Release Notes for HP-UX 11iv2 for 5.0MP1RP2 or 5.0MP2."
	2) Un-tar the tar-zipped patch downloaded from Symantec site to 
		a directory of your choice 
	3) Run swinstall command to install the Un-Official patch:
		swinstall -s <dir>/patches -x autoreboot=true UNOF_39781
	4) Configure the cluster. Refer to the VCS 5.0MP1RP2 or 5.0MP2 for 11iv2 
	   Release Notes for more information.

Perform the following steps to uninstall the VxFen UNOF Patch on the cluster:
To uninstall the VxFen UNOF Patch
	1) Run the following command to remove the Un-Official Patch from the cluster node:
		swremove -x autoreboot=true UNOF_39781
	2) Verify that the patch is removed from the system by running the following command:
		swlist | grep UNOF_39781
	If the patch gets removed successfully, the command will not display any output.