vcs-hpux1111-VRTSvcsag-3.5u4HF1

 Basic information
Release type: Hot Fix
Release date: 2009-10-14
OS update support: None
Technote: None
Documentation: None
Popularity: 837 viewed    downloaded
Download size: 7.5 KB
Checksum: 132546541

 Applies to one or more of the following products:
Cluster Server 3.5U4 On HP-UX 11i v1 (11.11)
Storage Foundation Cluster File System 3.5U4 On HP-UX 11i v1 (11.11)

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
1800228

 Patch ID:
PVCO_03899

Readme file
OS: HP-UX
OS Version: 11i v1
Fixes Applied for Products:
	VRTSvcsag - Veritas Cluster Server Bundled Agents

Additional Instructions:
Please read the instructions below before installing the patch.

    PATCH VCS 3.5 Update 4 HF1 for VRTSvcsag 3.5 Update 4
===============================================================

 	Patch Date:  October, 2009

This README provides information on:
 * BEFORE GETTING STARTED
 * FIXES AND ENHANCEMENTS INCLUDED IN THE PATCH
 * PACKAGES AFFECTED BY THE PATCH
 * INSTALLING THE PATCH
 * UNINSTALLING THE PATCH


BEFORE GETTING STARTED:
----------------------
This patch only applies to:
	VRTSvcsag 3.5 U4 running on HP-UX 11i v1 (11.11)

Ensure that you are running the supported configuration before
installing this patch.


FIXES AND ENHANCEMENTS INCLUDED IN THE PATCH: 
--------------------------------------------
Etrack Incidents: 1800228

SDR's of Fixed Symantec Incidents:
--------------------------------
Symantec Incident : 1800228
Symptom:
	Only first network host is logged by MultiNICA agent even when 
	the agent pings through all network hosts.
Defect Description:
	The MultiNICA agent pings each of the network host one by one, 
	but it logs only first network host.
Resolution:
	The resolution is to add a new log message that logs each 
	of the network hosts that the agent pings.


PACKAGES AFFECTED BY THE PATCH:
-------------------------------
This patch updates the following VCS package 
	VRTSvcsag from 3.5 Update 4 to 3.5 Update 4 HF1


INSTALLING THE PATCH:
--------------------
The following steps should be run on all nodes in the VCS cluster:

Stopping VCS on the cluster node:
--------------------------------
1. Ensure that "/opt/VRTS/bin" directory is included in your 
   PATH environment variable so you can execute all the VCS commands. 
   Refer to Veritas Cluster Server Installation Guide for more information.

2. Verify that the version of VRTSvcsag is 3.5 U4 for HP-UX 11i v1.

3. Freeze all the service groups persistently, on all nodes:
	# haconf -makerw
	# hagrp -freeze [group] -persistent
	# haconf -dump -makero

4. Stop the cluster on all nodes. If the cluster is writable, you may 
   close the configuration before stopping the cluster.
	# haconf -dump -makero

  From any node, execute the following command.
	# hastop -all
  or
	# hastop -all -force

  Verify that the cluster is stopped on all nodes by running the ha command.
	# hasys -state

   On all nodes, make sure that both had and hashadow processes are stopped. 


Installing the Patch:
--------------------
1. Un-compress the downloaded patch from Symantec.
   Change directory to the unzipped patch location. 
   Install the VRTSvcsag 3.5U4HF1 patch using the following command:
	# swinstall -s [dir]/patches PVCO_03899

2. Verify that the new patch has been installed:
	# swlist  PVCO_03899
   You will find the following output on display with the patch 
   installed properly:
PVCO_03899    1.0       Veritas Cluster Server Bundled Agents Command Patch


Re-starting VCS on the cluster node:
-----------------------------------
1. At this time, you can start the cluster services on all cluster nodes. 
   First start VCS on one node:
    # hastart

   On all the other nodes, start VCS by issuing hastart after the first node
   goes to LOCAL_BUILD or RUNNING state.

2. Unfreeze all the groups.
     # haconf -makerw
     # hagrp -unfreeze [group] -persistent
     # haconf -dump -makero


UNINSTALLING THE PATCH:
-----------------------
Follow the steps given below in all the systems:

Steps to remove the Patch from a cluster node:
---------------------------------------------
1. Follow the steps provided under "Stopping VCS on the cluster node" 
   section above, to stop VCS on the node.

2. Remove the patch by the following command:
	# swremove PVCO_03899

3. Verify that the patch has been removed from the system:
	# swlist  PVCO_03899
   If the patch gets removed successfully, the command will not display 
   any output.

4. Follow the steps in "Re-starting VCS on the cluster node" section above 