This page lists publically-released patches for Veritas Enterprise Products.
For Product GA build, see Veritas Entitlement Management System(VEMS) by clicking the Veritas Support 'Licensing' option.
For information on private patches, contact Veritas Technical Support.
Veritas is making it easier to find all software installers and updates for Veritas products with a completely redesigned experience. NetBackup HotFixes and NetBackup Appliance patches are now also available at the new Veritas Download Center.
Patches for your product can have a variety of names. These names are based on product, component, or package names. For more information on patch naming conventions and the relationship between products, components, and packages, see the SORT online help.
vcs_agents-hpux1131-VRTSvcsor-5.0RP2HF2
Sign in if you want to rate this patch.

 Basic information
Release type: Hot Fix
Release date: 2009-11-05
OS update support: None
Technote: 337955
Documentation: None
Popularity: 1041 viewed    30 downloaded
Download size: 4.14 MB
Checksum: 3618657848

 Applies to one or more of the following products:
Cluster Server Agents 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation for Oracle 5.0 On HP-UX 11i v3 (11.31)
Storage Foundation for Oracle RAC 5.0 On HP-UX 11i v3 (11.31)

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch supersedes the following patches: Release date
vcs_agents-hpux1131-VRTSvcsor-5.0RP2HF1 (obsolete) 2009-07-22
vcs_agents-hpux1131-VRTSvcsor-5.0RP2 (obsolete) 2009-06-09

 Fixes the following incidents:
1876991, 1881827

 Patch ID:
PVCO_03901

 Readme file  [Save As...]
OS: HP-UX
OS Version: 11i v3
Fixes Applied for Products:
	VRTSvcsor - Veritas High Availability Agent for Oracle by Symantec

Additional Instructions:
Please read the instructions below before installing the patch.

 PATCH VRSTvcsor 5.0RP2HF2 for VCS Oracle Agent 5.0RP2
===============================================================

 Patch Date:  November, 2009

This README provides information on:
 * BEFORE GETTING STARTED
 * FIXES AND ENHANCEMENTS INCLUDED IN THE PATCH
 * PACKAGES AFFECTED BY THE PATCH
 * INSTALLING THE PATCH
 * UNINSTALLING THE PATCH


BEFORE GETTING STARTED:
----------------------
This patch only applies to:
	VRTSvcsor 5.0RP2 running on HP-UX 11iv3

Ensure that you are running the supported configurations before
installing this patch.


FIXES AND ENHANCEMENTS INCLUDED IN THE PATCH: 
--------------------------------------------
Etrack Incidents: 1876991, 1881827

SDR's of Fixed Symantec Incidents:
--------------------------------
Symantec Incident : 1876991
Symptom:
	Oracle Agent was not able to send SNMP/SMTP notifications 
	in case of any error defined in oraerror.dat file.
Defect Description:
	There was a problem in forming the hanotify(1m) command 
	in Oracle Agent, while sending notifications.
Resolution:
	The problem is now fixed to correctly form the hanotify(1m) 
	command in Oracle Agent, while sending notifications.


Symantec Incident : 1881827
Symptom:
	With different kind of errors, the agent used to take actions
	corresponding to the last received error, ignoring the rest.
Defect Description:
	With this parsing method, Oracle agent may ignore some 
	important actions, specified in oraerror.dat file,
	which could result in inconsistency of the state of the resource.
Resolution:
	The parsing method is updated to prioritize certain actions, 
	when multiple errors occur at a time.


PACKAGES AFFECTED BY THE PATCH:
-------------------------------
This patch updates the following VCS package(s) 
	VRTSvcsor from 5.0RP2 or higher on 11iv3 to 5.0RP2HF2 on 11iv3


INSTALLING THE PATCH:
--------------------
The following steps should be run on all nodes in the VCS cluster:

Stopping VCS Oracle Agent on the cluster node:
---------------------------------------------
Stop Oracle agent using:
	# haagent -stop Oracle -sys [system_name] -force

Installing the Patch:
--------------------
1. Un-compress the downloaded patch from Symantec.
   Change directory to the unzipped patch location. 
   Install the VRTsvcsor(PVCO_03901) patch using the following command:
	# swinstall -s `pwd`/patches -x autoreboot=true PVCO_03901

2. Verify that the new patch has been installed:
	# swlist PVCO_03901
   You will find the following output on display with the patch installed properly:
	  PVCO_03901    1.0            VRTS 5.0 RP2 HF2 VRTSvcsor Command Patch

Re-start VCS Oracle Agent on the cluster node:
---------------------------------------------
After successful installation of the patch, run the following command 
for restarting the agents :
	# haagent -start Oracle -sys [sysname]


UNINSTALLING THE PATCH:
-----------------------
Steps to remove the Patch from a cluster node:
---------------------------------------------
1. Follow the steps provided under 
   "Stopping VCS Oracle Agent on the cluster node" 
   section above, to stop Oracle Agent on the node.

2. Remove the patch by the following command:
	# swremove -x autoreboot=true PVCO_03901

3. Verify that the patch has been removed from the system:
	# swlist | grep  PVCO_03901
   There will be no output on the display following this command,
   for a successful removal.

4. Restart the agent following the steps under 
   "Re-start VCS Oracle Agent on the cluster node" section above.