CommandCentral 5.1.1 On Solaris SPARC
|
None.
|
2038078
|
None.
|
Date:2010-07-15 OS:Solaris, Windows Etrack Incidents: 2038078 Case ID: 411-885-312 Errors/Problems Fixed:[ Clariion explorer intermittent discovery on array - Array log errors when discovering binding (Masked luns) on EMCClariion arrays. ] Fix:[ If ClariionNoPoll flag is set in the registry, CLARiiON explorer now uses -np flag to execute CLI and get the cached data. ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the HotFix --------------------------------------------------------------------------- Apply the HotFix (VRTSccs-F511002038078) on the 5.1.1 Management Server and managed hosts with array and switch explorers. Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 B - Deploying the HotFix from a Windows Management Server -------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win-5.1.1HF511002038078w.zip to a temporary location. For example, to C:\Temp 2. After extracting the hotfix, the below two files will be available. - patches\ - patches\VRTSccs-F511002038078.tar.gz - README (this file) 3. To apply the update, do the following: - Open an operating system console. - Change to the HAL bin directory: "C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin" - Type the following command: halsecurity login You may have to provide the password for the 'admin' account which you use to log in to the Console. The default password for this account is 'password' (without single quotes). - Type the following command to deploy the update on the Management Server: <HAL bin dir>\perl LocalUpgrade.pl C:\Temp\patches\VRTSccs-F511002038078.tar.gz - To get a list of all managed hosts in a text file, run the following command: perl CHMGetManagedHosts.pl -f C:\Temp\mhs.txt The newly-created text file mhs.txt includes the list of all managed hosts and the Management Server. - Edit mhs.txt to keep only the names of those hosts on which you want to update to 5.1.1 Array Agent HotFix. - To deploy the update to the hosts listed in C:\temp\mhs.txt, run the following command: perl PushUpgrade.pl -u C:\Temp\patches\VRTSccs-F511002038078.tar.gz -H C:\Temp\mhs.txt 4. To verify the installation, you can check the installation logs as follows: - To see the detailed logs, go to the "CommandCentral Storage Data" directory. The default location is: "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint" cd "<HAL data dir>\Data\HAL\maint\VRTSccs-F511002038078\<timestamp>\output" For example: cd "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\ VRTSccs-F511002038078\<time stamp>\output" - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: "C:\Program Files\VERITAS\CommandCentral Storage\Version\cc_version.txt" - Check the FIXID. It should appear as follows: FIXID=F511002038078 DATE=Fri Jul 16 15:21:55 2010 DESCRIPTION=HotFix for EMC CLARiiON explorer C - Deploying the HotFix from a Solaris Management Server --------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy the file ccs-sol_sparc-5.1.1HF511002038078u.tar.gz to a temporary location. For example, to /tmp and unpack it. 2. After extracting the hotfix, you'll find the files shown below: - patches/ - patches/VRTSccs-F511002038078.tar.gz - README (this file) 3. To apply the update, do the following: - Open an operating system console. - Change to the HAL bin directory: /opt/VRTSccs/VRTShal/bin - Type the following command: ./halsecurity login You may have to provide the password for the 'admin' account which you use to log in to the Console. The default password for this account is 'password' (without single quotes). - Type the following command to deploy the update: <HAL bin dir>perl LocalUpgrade.pl </tmp>/patches/VRTSccs-F511002038078.tar.gz For example: ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F511002038078.tar.gz - To get a list of all managed hosts in a text file, run the following command: ./perl CHMGetManagedHosts.pl -f /tmp/mhs.txt The newly-created text file includes the list of all managed hosts and the Management Server. - Edit mhs.txt to keep only the names of those hosts on which you want to apply the 5.1.1 Array Agent HotFix. - To deploy the update to the hosts listed in /tmp/mhs.txt, run the following command: ./perl PushUpgrade.pl -u /tmp/patches/VRTSccs-F511002038078.tar.gz -H /tmp/mhs.txt 4. To verify the installation, you can check the installation logs as follows: - To see the detailed logs, go to the CommandCentral Storage Data directory. The default location is: /var/VRTSccs/data/VRTShal/maint/VRTSccs-F511002038078/<time stamp>/output cd <HAL data dir>/data/VRTShal/maint/VRTSccs-F511002038078/<time stamp>/output For example: cd /var/VRTSccs/data/VRTShal/maint/VRTSccs-F511002038078/<time stamp>/output - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: /opt/VRTS/version/cc_version.txt - Check the FIXID. It should appear as follows: FIXID=F511002038078 DATE=Fri Jul 16 15:21:55 2010 DESCRIPTION=HotFix for EMC CLARiiON explorer Additional Notes: ================== Apply the HotFix (VRTSccs-F511002038078) on the 5.1.1 Management Server and managed hosts with array and switch explorers. |
Why Register?
Get notifications about ASLs/APMs, HCLs, patches, and high availability agents
As a registered user, you can create notifications to receive updates about NetBackup Future Platform and Feature Plans, NetBackup hot fixes/EEBs in released versions, Array Support Libraries (ASLs)/Array Policy Modules (APMs), hardware compatibility lists (HCLs), patches and high availability agents. In addition, you can create system-specific notifications customized to your environment.
Compare configurations
The Compare Configurations feature lets you compare different system scans by the data collector. When you sign in, you can choose a target system, compare reports run at different times, and easily see how the system's configuration has changed.
Save configurations
After logging in, you can retrieve past reports, share reports with colleagues, review notifications you received, and retain custom settings. Anonymous users cannot access these features.
Bulk uploader
As a registered user,you can upload multiple reports, using the Bulk Uploader.