ccs-sol_sparc-5.2RU1HF520012390317u2

 Basic information
Release type: Hot Fix
Release date: 2011-06-30
OS update support: None
Technote: None
Documentation: None
Popularity: 3097 viewed    downloaded
Download size: 53.25 KB
Checksum: 2336931397

 Applies to one or more of the following products:
CommandCentral 5.2RU1 On Solaris SPARC

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
2226597, 2238171, 2280662, 2323006, 2390317, 2404749

 Patch ID:
None.

Readme file
Date:2011-June-07

OS: Solaris,  Windows 

Etrack Incidents: 2238171, 2280662, 2323006, 2390317, 2404749, 2226597

Problems Fixed: [
  - DB Inserts/Updates becomes slow due to large number of history records (e2238171)
  - SAN and NAS Waterfall Report performance issue (e2280662)
  - VmwareExplorer DCT performance issue (e2323006)
  - Slow GUI pages load times for Array Summary, NAS, and Host Summary (e2390317)
  - login to UI hangs due to lock on vxam.session table (e2404749)
  - Tmp db file may grow very large when running specific Ad-Hoc Report (e2226597)

]

Install/Uninstall Instructions:
===========================================================================
Instructions to apply the hotfix
===========================================================================


A - Overview of the HotFix
---------------------------------------------------------------------------

NOTE: PLEASE WAIT AT LEAST 3 DAYS AFTER UPGRADE TO CommandCentral Storage 
      Management Server 5.2RU1 FROM 5.1x BEFORE APPLYING THE HOTFIX.
      THIS IS TO MAKE SURE DISCOVERY COMPLETE FOR ALL MANAGED HOSTS.

Apply the HotFix (VRTSccs-F520012390317) on CommandCentral Storage 5.2RU1 Management Server.

Supported operating systems include:

  - Solaris 8, 9, and 10
  - Windows Server 2000, 2003, and 2008


B - Deploying the HotFix on a Windows Management Server
--------------------------------------------------------------------------

The examples in the following procedure assume that you installed
CommandCentral on a 32-bit host in the default installation directory.

1. Copy ccs-win-5.2RU1HF520012390317w2.zip to a temporary location. For
   example,    to C:\Temp

2. After extracting the hotfix,    the below two files will be available.
    - patches
    - patches\VRTSccs-F520012390317.tar.gz
    - README  (this file)

3. To apply the update,    do the following:

   - Open an operating system console.
   - Change to the HAL bin directory:
       C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin;

   - Type the following command:
       halsecurity login
     You may have to provide the password for the 'admin' account
     which you use to log in to the Console. The default password for
     this account is 'password' (without single quotes).

   - Type the following command to deploy the update on the Management Server:
       <HAL bin dir>\perl LocalUpgrade.pl "C:\Temp\patches\VRTSccs-F520012390317.tar.gz"

4. To verify the installation, you can check the installation logs as follows:

   - To see the detailed logs, go to the 'CommandCentral Storage Data'
     directory.
     The default location is:
       C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint;

       cd <HAL data dir>\Data\HAL\maint\VRTSccs-F520012390317\<timestamp>\output;
     For example:

       cd C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\
       VRTSccs-F520012390317\<time stamp>\output;

   - Check if there are any errors in the stderr.txt file.
   - Check the detailed logs of the hotfix application in the stdout.txt file.


5. Verify the updated version as follows:
   - Open cc_version.txt from the following directory:
     C:\Program Files\VERITAS\CommandCentral Storage\Version\cc_version.txt;

   - Check the FIXID. It should appear as follows:

      FIXID=F520012390317
      DATE=Mon June 06 17:37:39 2011
      DESCRIPTION=CommandCentral Storage 5.2RU1 Management Server Database HotFix


C - Deploying the HotFix on a Solaris Management Server
---------------------------------------------------------

The examples in the following procedure assume that you installed
CommandCentral on a 32-bit host in the default installation directory.

1. Copy the file ccs-sol_sparc-5.2RU1HF520012390317u2.tar.gz to a
   temporary location. For example,    to /tmp and unpack it.

2. After extracting the hotfix,   you will find the files shown below:
    - patches/
    - patches/VRTSccs-F520012390317.tar.gz
    - README  (this file)

3. To apply the update,    do the following:

   - Open an operating system console.

   - Change to the HAL bin directory:
       /opt/VRTSccs/VRTShal/bin

   - Type the following command:
       ./halsecurity login
     You may have to provide the password for the 'admin' account
     which you use to log in to the Console. The default password for
     this account is 'password' (without single quotes).
   - Type the following command to deploy the update:
       <HAL bin dir>\perl LocalUpgrade.pl /tmp/patches/VRTSccs-F520012390317.tar.gz

     For example:
        ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F520012390317.tar.gz

4. To verify the installation,    you can check the installation logs as follows:

   - To see the detailed logs,    go to the CommandCentral Storage Data
     directory.
     The default location is:
        /var/VRTSccs/data/VRTShal/maint/VRTSccs-F520012390317/<time stamp>/output
        cd <HAL data dir>/data/VRTShal/maint/VRTSccs-F520012390317/<time stamp>/output
     For example:
       cd /var/VRTSccs/data/VRTShal/maint/VRTSccs-F520012390317/<time stamp>/output

   - Check if there are any errors in the stderr.txt file.
   - Check the detailed logs of the hotfix application in the stdout.txt file.

5. Verify the updated version as follows:

   - Open cc_version.txt from the following directory:
       /opt/VRTS/version/cc_version.txt
   - Check the FIXID. It should appear as follows:

      FIXID=F520012390317
      DATE=Mon June 06 17:37:39 2011
      DESCRIPTION=CommandCentral Storage 5.2RU1 Management Server Database HotFix#


Additional Notes:
==================
- Apply the HotFix (VRTSccs-F520012390317) on the CommandCentral Storage 5.2RU1 Management Server only.

- PLEASE WAIT AT LEAST 3 DAYS AFTER UPGRADE TO CommandCentral Storage Management Server 5.2RU1 
  FROM 5.1x BEFORE APPLYING THE HOTFIX.  THIS IS TO MAKE SURE DISCOVERY COMPLETE FOR ALL MANAGED HOSTS.