vom-HF040010970-08

 Basic information
Release type: Hot Fix
Release date: 2011-07-24
OS update support: None
Technote: None
Documentation: None
Popularity: 400 viewed    downloaded
Download size: 77.21 KB
Checksum: 1691442776

 Applies to one or more of the following products:
Operations Manager 4.0 On AIX
Operations Manager 4.0 On HP-UX 11i v2 (11.23)
Operations Manager 4.0 On HP-UX 11i v3 (11.31)
Operations Manager 4.0 On Linux
Operations Manager 4.0 On RHEL4 ppc64
Operations Manager 4.0 On RHEL5 ppc64
Operations Manager 4.0 On SLES10 ppc64
Operations Manager 4.0 On SLES11 ppc64
Operations Manager 4.0 On SLES9 ppc64
Operations Manager 4.0 On Solaris 10 X64
Operations Manager 4.0 On Solaris SPARC
Operations Manager 4.0 On Solaris x64

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
2433876

 Patch ID:
None.

Readme file
             * * * READ ME * * *
             * * * Veritas Operations Manager  *
             * * * Hot Fix 040010970-08  * * *

This document provides the following information:

   * PATCH NAME
   * PACKAGES AFFECTED BY THE PATCH
   * BASE PRODUCT VERSIONS FOR THE PATCH
   * OPERATING SYSTEMS SUPPORTED BY THE PATCH
   * INCIDENTS FIXED BY THE PATCH
   * INSTALLATION PRE-REQUISITES
   * INSTALLING THE PATCH
   * REMOVING THE PATCH


PATCH NAME
----------
Veritas Operations Manager Hot Fix 040010970-08


PACKAGES AFFECTED BY THE PATCH
------------------------------
VRTSsfmh


BASE PRODUCT VERSIONS FOR THE PATCH
-----------------------------------
   * Veritas Operations Manager 4.0


OPERATING SYSTEMS SUPPORTED BY THE PATCH
----------------------------------------
Linux, Solaris, AIX, HP-UX


INCIDENTS FIXED BY THE PATCH
----------------------------
This patch fixes the following Symantec incidents:

* 2433876


SYMPTOM:
SUBSYS_ID is NULL , due to which Incorrect Mirror on same enclosure is reported. 

DESCRIPTION:
HF040010970-08.sfa is applicable for VOM 4.0 for central server and managed host.


HF 040010970-08 addresses the following issue:
In delta runs, the disk to enclosure mapping is not reported which causes corelation to fail and then we  see false positives in the PC checks

RESOLUTION:
During delta discovery ensure that disk to enclosure mapping is reported.

INSTALLING THE PATCH
--------------------
This hotfix is applicable for VOM Central Server. 
It has to be installed on the VOM CMS. 

1. Download the file "HF040010970-08.sfa".
2. Launch a browser and login to the VOM management server.
3. Navigate to Settings -> Deployment Management tab.
4. Upload the add-on to the VOM CMS using the "upload" button.
   The HF HF040010970-08 should be  visible in the table below.
5. Select the HF and install it.


REMOVING THE PATCH
------------------
1. Launch a browser and login to the VOM management server.
2. Navigate to Settings -> Deployment Management tab.
3. Select the add-on. This will take you to the page which shows the status of the HF on all hosts.
Uninstall it from the VOM CS host.