data_insight-2.5RP2HF1

 Basic information
Release type: Hot Fix
Release date: 2011-09-15
OS update support: None
Technote: None
Documentation: None
Popularity: 3323 viewed    downloaded
Download size: 3.75 MB
Checksum: 3436873779

 Applies to one or more of the following products:
Data Insight 2.5 On Windows 32-bit
Data Insight 2.5 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
2525188

 Patch ID:
None.

Readme file
Date:2011-09-15

OS: Windows

Etrack Incidents: 2525188

Errors/Problems Fixed:

For EMC Celerra, shares which are configured to be seen by all cifs
servers on a data mover are not visible to cifs servers for other data movers.
Data Insight share discovery code incorrectly lists those shares against cifs 
servers of all data movers on the EMC Celerra device.
(2525188) [Applies to: Collector]


Install/Uninstall Instructions:

Apply this hotfix on each Collector worker node connecting to EMC file servers.
This hotfix can be applied to Data Insight version 2.5RP2 only.

FILE AFFECTED BY THIS PATCH:

INSTALL_ROOT\DataInsight\bin\cel_util.exe
INSTALL_ROOT\DataInsight\pdb\cel_util.pdb

By default, value of INSTALL_ROOT is "C:\Program Files\Symantec". 

NOTE: Please keep a backup of the files  you are about to patch. This will be
required in case you want to rollback the patch.

Steps:
For each Collector worker node connecting to EMC file servers, log onto the
server with Administrative privileges and perform the following steps:

1. Stop Data Insight services:
From the command prompt, issue the following commands:

net stop DataInsightComm
net stop DataInsightWeb

NOTE: Depending on the type of Data Insight node, some services might or might
not be present. Ignore error if the service could not be stopped because it is
not configured.

2. Unzip the patch files to a temporary folder. In this folder, locate the
"patches" folder. The patch contains files for both 32bit and 64bit installs.
Select the appropriate folder based on the processor architecture of your
server. Files provided in the patch are in the same directory hierarchy as those
present on your system at: "INSTALL_ROOT\DataInsight".
Example: If you unzip hotfix to C:\temp, it will create the following folders 
under C:\temp:
C:\TEMP
+---README
+---patches
    +---32bit
        +---bin
        +---pdb
    +---64bit
        +---bin
        +---pdb
If you are patching a 32 bit server installed at "C:\Program Files\Symantec\DataInsight",
copy entire contents under "C:\temp\patches\32bit" to 
"C:\Program Files\Symantec\DataInsight", replacing the original files with those
from the patch.

3. Start Data Insight services:
From the command prompt, issue the following commands:

net start DataInsightComm
net start DataInsightWeb

NOTE: Depending on the type of Data Insight node, some services might or might
not be present. Ignore error if the service could not be started because it is
not configured.


Additional Notes:
Apply this hotfix to Data Insight 2.5 patched with Rolling Patch 
'data_insight-2.5RP2' only. The Rolling Patch 'data_insight-2.5RP2'
is available at: https://sort.symantec.com/patch/detail/5458