|
---|
Release type: | Rolling Patch |
Release date: | 2011-12-01 |
OS update support: | None |
Technote: | None |
Documentation: | None |
Popularity: | 670 viewed downloaded |
Download size: | 109.23 MB |
Checksum: | 2690022615 |
Data Insight 2.5.1 On Windows 32-bit
Data Insight 2.5.1 On Windows 64-bit |
None.
|
1746975, 2042903, 2579205, 2611169, 2612939, 2613061, 2613953, 2624287, 2624378
|
None.
|
Date:2011-11-24 OS: Windows Etrack Incidents: 1746975, 2613061, 2611169, 2042903, 2579205, 2613953, 2624287, 2612939, 2613061, 2624378 Errors/Problems Fixed: Since 2.5RU1_RP1: Data ownership based reports take a long time to generate output for large number of shares. NOTE: With this fix, report output is restricted to 1, 00, 000 output rows. To configure a different limit, edit reportcli.vmoptions file on management server and change the following line as needed: -Dreport.details.limit=100000 (1746975) [Applies to: management server, indexer] collector.exe process takes excessive memory when consuming large number of audit event files. (2613061) [Applies to: all] scanner.exe process takes excessive memory and CPU when scanning large number of paths during incremental scans. (2611169) [Applies to: all] Path permissions report does not allow user to exclude Share level ACLs when computing effective permissions. (2042903) [Applies to: management server, indexer] Share discovery is not accurate for clustered Windows 2003 Windows File Servers where multiple virtual file servers have been configured for the same cluster. (2579205) [Applies to: windows file server agent, collector] Scanner continues to scan even if a large number of paths have errors scanning. NOTE: With this fix, scanner will exit if it encounters errors on more than 5000 paths. To set a different limit, execute the following command on the management server: configdb.exe -o -T node -k <node_id> -J scanner.max_err -j <new_value> To obtain node_id of the appropriate collector/windows file server agent, issue the following command: configdb.exe --print --type node (2613953) [Applies to: windows file server agent, collector] Index writer fails in certain rename event scenarios. (2624287) [Applies to: indexer] Latency of a netapp filer can be affected in case of network misconfiguration between filer and the collector node. NOTE: With this fix, Data Insight can be configured to disconnect fpolicy of a filer if latency of the filer exceeds any of the configured high watermarks. Data Insight will connect back once latency falls below all configured low watermarks. You can specify a minimum sleep time between a disconnection and reconnection event. Latency values are averaged over specified number of samples each 20 seconds apart. Issue following commands on the management server to configure this feature: configdb.exe -O -J events.disconn.fpolicy.watermark.high.cifs_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.watermark.high.cifs_write_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.watermark.high.cifs_read_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.watermark.low.cifs_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.watermark.low.cifs_write_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.watermark.low.cifs_read_latency -j <ms> configdb.exe -O -J events.disconn.fpolicy.samples -j <num_samples> configdb.exe -O -J events.disconn.fpolicy.quiet_time -j <minutes> configdb.exe -O -J events.disconn.fpolicy.enabled -j true (2612939) [Applies to: collector] Index writer can fail for large number of input events. With this fix, index writer will be configured to process 1 million events at one time. This value can be changed from Advanced Settings page for the indexer. (2613061) [Applies to: indexer] If scanner throttling for netapp filers has been enabled, full and incremental scans for shares of vfilers fail with error 212. (2624378) [Applies to: windows file server agent, collector] Install/Uninstall Instructions: Apply this rolling patch on all Data Insight servers with version 2.5RU1 (2.5.1). FILES AFFECTED BY THIS PATCH: INSTALL_ROOT\DataInsight\bin\mxlog.dll INSTALL_ROOT\DataInsight\bin\mindexer.dll INSTALL_ROOT\DataInsight\bin\dbhandle.dll INSTALL_ROOT\DataInsight\bin\DataInsight.dll INSTALL_ROOT\DataInsight\bin\inactive.dll INSTALL_ROOT\DataInsight\bin\inactive_data.dll INSTALL_ROOT\DataInsight\bin\inactive_data_by_owner.dll INSTALL_ROOT\DataInsight\bin\rptlib.dll INSTALL_ROOT\DataInsight\bin\storage_by_domain.dll INSTALL_ROOT\DataInsight\bin\storage_by_owner.dll INSTALL_ROOT\DataInsight\bin\storage_by_type_and_owner.dll INSTALL_ROOT\DataInsight\bin\fid_size.dll INSTALL_ROOT\DataInsight\bin\scanner.exe INSTALL_ROOT\DataInsight\bin\collector.exe INSTALL_ROOT\DataInsight\bin\winnas_util.exe INSTALL_ROOT\DataInsight\bin\report.exe INSTALL_ROOT\DataInsight\bin\idxreader.exe INSTALL_ROOT\DataInsight\bin\queryd.exe INSTALL_ROOT\DataInsight\bin\fpolicyd.exe INSTALL_ROOT\DataInsight\bin\idxwriter.exe -- INSTALL_ROOT\DataInsight\pdb\mxlog.pdb INSTALL_ROOT\DataInsight\pdb\mindexer.pdb INSTALL_ROOT\DataInsight\pdb\dbhandle.pdb INSTALL_ROOT\DataInsight\pdb\DataInsight.pdb INSTALL_ROOT\DataInsight\pdb\inactive.pdb INSTALL_ROOT\DataInsight\pdb\inactive_data.pdb INSTALL_ROOT\DataInsight\pdb\inactive_data_by_owner.pdb INSTALL_ROOT\DataInsight\pdb\rptlib.pdb INSTALL_ROOT\DataInsight\pdb\storage_by_domain.pdb INSTALL_ROOT\DataInsight\pdb\storage_by_owner.pdb INSTALL_ROOT\DataInsight\pdb\storage_by_type_and_owner.pdb INSTALL_ROOT\DataInsight\pdb\fid_size.pdb INSTALL_ROOT\DataInsight\pdb\scanner.pdb INSTALL_ROOT\DataInsight\pdb\collector.pdb INSTALL_ROOT\DataInsight\pdb\winnas_util.pdb INSTALL_ROOT\DataInsight\pdb\report.pdb INSTALL_ROOT\DataInsight\pdb\idxreader.pdb INSTALL_ROOT\DataInsight\pdb\queryd.pdb INSTALL_ROOT\DataInsight\pdb\fpolicyd.pdb INSTALL_ROOT\DataInsight\pdb\idxwriter.pdb -- INSTALL_ROOT\DataInsight\tomcat\webapps\ROOT\WEB-INF\classes INSTALL_ROOT\DataInsight\tomcat\webapps\ROOT\ui INSTALL_ROOT\DataInsight\lib\console_launcher.jar INSTALL_ROOT\DataInsight\tomcat\webapps\symhelp NOTE: Please keep a backup of the files you are about to patch. This will be required in case you want to manually rollback the patch. High Level Steps: 1. Apply the rolling patch on Management Server first, followed by all Worker Nodes. 2. Next, apply patch to Windows File Server agents. Patching Data Insight Management Server and Worker Nodes: 1. Log onto each server with Administrative privileges. 2. Unzip the patch files to a temporary folder. In this folder, locate the rolling patch installer for the appropriate OS architecture. The installer is called Symantec_DataInsight_windows_251RP1_2_5_1_1665_x64.exe for 64 bit OS and Symantec_DataInsight_windows_251RP1_2_5_1_1665_x86.exe for 32 bit OS. 3. Launch the installer executable to install the rolling patch. Patching Data Insight Windows File Server agents: 1. Unzip the patch files to a temporary folder. In this folder, locate the rolling patch installer bundles for Windows File Server agents. The agent bundle is called Symantec_DataInsight_windows_winnas_251RP1_2_5_1_1665_x64.zip for 64 bit OS and Symantec_DataInsight_windows_winnas_251RP1_2_5_1_1665_x86.zip for 32 bit OS. 2. Log into the Management Console with Server Administrator privilege and upload the agent bundles to the appropriate collector worker nodes using "Agent Uploader" page in the Settings tab. 3. Navigate to Filer details page for each configured Windows File Server in the Settings tab and click on "Upgrade Agent" button available on the top of the page. This option is only visible if you have enabled the option to let Data Insight install/upgrade agent for this filer. 4. Alternately, to manually patch a Windows File Server agent, log onto the Windows File Server machine with Administrative privileges, unzip the agent installer bundle in a temporary location, and launch the patch installer. The patch installer is called Symantec_DataInsight_windows_winnas_251RP1_2_5_1_1665_x64.exe for 64 bit OS, and Symantec_DataInsight_windows_winnas_251RP1_2_5_1_1665_x86.exe for 32 bit OS. Additional Notes: 1. At this time, automated roll back of patch is not supported. To roll back the patch manually: a. Remember to take a backup of original files before you install the rolling patch. b. To roll back the patch, stop all Data Insight services, overwrite the patched files with original files from backup, and restart services. 2. To confirm if a system has been patched, check the version of Data Insight using "Add/Remove Programs" applet in the Control Panel. |
Why Register?
Get notifications about ASLs/APMs, HCLs, patches, and high availability agents
As a registered user, you can create notifications to receive updates about NetBackup Future Platform and Feature Plans, NetBackup hot fixes/EEBs in released versions, Array Support Libraries (ASLs)/Array Policy Modules (APMs), hardware compatibility lists (HCLs), patches and high availability agents. In addition, you can create system-specific notifications customized to your environment.
Compare configurations
The Compare Configurations feature lets you compare different system scans by the data collector. When you sign in, you can choose a target system, compare reports run at different times, and easily see how the system's configuration has changed.
Save configurations
After logging in, you can retrieve past reports, share reports with colleagues, review notifications you received, and retain custom settings. Anonymous users cannot access these features.
Bulk uploader
As a registered user,you can upload multiple reports, using the Bulk Uploader.