Release type: | Hot Fix |
Release date: | 2012-10-26 |
OS update support: | None |
Technote: | None |
Documentation: | None |
Popularity: | 309 viewed downloaded |
Download size: | 20.98 MB |
Checksum: | 194172253 |
CommandCentral 5.2RU3 On Solaris SPARC
|
None.
|
2853118, 2869371, 2869538, 2875114, 2896795, 2903493, 2915491, 2932101, 2957824, 2962652, 2965962
|
None.
|
Date: 2012-Oct-18 OS: Solaris, Windows Etrack Incidents: 2932101, 2962652, 2965962, 2957824, 2896795, 2869538, 2915491, 2903493, 2869371, 2875114, 2853118 Errors/Problems Fixed:[ - Number of active Data Collection Tasks (DCTs) are decreasing with time (e2932101) - HALCHM taking long time to process EMCSymmetrixExplorer DCT's (e2962652) - Storage Array LUN page takes long time to load(e2965962) - Some LUNs appear to be in the wrong Disk Groups (e2957824) - Brocade DCX discovery incorrect in GUI (e2896795) - Unhandled java exception on Thin Pool Tab page (e2869538) - Unable to export and email custom reports (e2915491) - CommandCentral Storage shows negative Overhead values of HITACHI Thin Pools (e2903493) - DCT takes long time and builds a DCT queue (e2869371) - LUNs are missing from the CCS Database (e2875114) - Slow GUI performance while viewing Array LUN tab and Host Storage tab (e2853118) ] Install/Uninstall Instructions: =========================================================================== Instructions to apply the hotfix =========================================================================== A - Overview of the HotFix --------------------------------------------------------------------------- 1. Apply the HotFix (VRTSccs-F520032962652) on 5.2RU3 CommandCentral Storage Management Servers having below hotfix installed - F520032819385 2. Supported operating systems include: - Solaris 8, 9, and 10 - Windows Server 2000, 2003, and 2008 3. Expected time taken by hotfix installation process is around 15 minutes. B - Deploying the patch 'VRTSccs-F520032962652.tar.gz' on Windows Management Server ------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy ccs-win32-5.2RU3HF520032962652w-patches.zip to a temporary location. For example, to C:\Temp 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520032962652.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the CommandCentral HAL bin directory: "C:\Program Files\VERITAS\CommandCentral Storage\HAL\bin" - Run the following command: perl LocalUpgrade.pl "C:\Temp\patches\VRTSccs-F520032962652.tar.gz" 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory. "C:\Program Files\VERITAS\CommandCentral Storage Data\Data\HAL\maint\ \VRTSccs-F520032962652\output" - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open cc_version.txt from the following directory: For Windows: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520032962652 DATE=Thur Oct 18 15:11:34 2012 DESCRIPTION=CommandCentral Storage 5.2RU3 Management Server HotFix#6 REQUIREFIXES=F520032819385 OBSOLETES=F520032768725, F520032749322, F520032869371, F520032903493 C - Deploying the patch 'VRTSccs-F520032962652.tar.gz' on a Solaris Management Server ----------------------------------------------------------------------------------------- The examples in the following procedure assume that you installed CommandCentral on a 32-bit host in the default installation directory. 1. Copy the file ccs-sol_sparc-5.2RU3HF520032962652u-patches.tar.gz to a temporary location. For example, to /tmp and unpack it. 2. After extracting the hotfix, the below three files will be available. - patches - patches\VRTSccs-F520032962652.tar.gz - README (this file) 3. To apply the update on the Management Server, do following: - Go to the HAL bin directory: /opt/VRTSccs/VRTShal/bin - Type the following command: ./perl LocalUpgrade.pl /tmp/patches/VRTSccs-F520032962652.tar.gz 4. To verify the installation, check the installation logs on the Management Server as follows: - Go to the CommandCentral Storage HAL Data directory: /var/VRTSccs/data/VRTShal/maint/VRTSccs-F520032962652/output - Check if there are any errors in the stderr.txt file. - Check the detailed logs of the hotfix application in the stdout.txt file. 5. Verify the updated version as follows: - Open the cc_version.txt file from the following directory: For Windows hosts: "C:\Program Files\VERITAS\CommandCentral Storage\Version" For UNIX hosts: /opt/VRTS/version/ - Check the FIXID. It should look like this FIXID=F520032962652 DATE=Thur Oct 18 15:11:34 2012 DESCRIPTION=CommandCentral Storage 5.2RU3 Management Server HotFix#6 REQUIREFIXES=F520032819385 OBSOLETES=F520032768725, F520032749322, F520032869371, F520032903493 Additional Notes: ================== - Apply the HotFix (VRTSccs-F520032962652) on 5.2RU3 CommandCentral Storage Management Servers having below hotfix installed - F520032819385 - Expected time taken by hotfix installation process is around 15 minutes. - To get the complete fix for issue e2903493, below hotfix is also required to apply on Management Server and Control Hosts from where Hitachi arrays are configured - F520032930950 |
Why Register?
Get notifications about ASLs/APMs, HCLs, patches, and high availability agents
As a registered user, you can create notifications to receive updates about NetBackup Future Platform and Feature Plans, NetBackup hot fixes/EEBs in released versions, Array Support Libraries (ASLs)/Array Policy Modules (APMs), hardware compatibility lists (HCLs), patches and high availability agents. In addition, you can create system-specific notifications customized to your environment.
Compare configurations
The Compare Configurations feature lets you compare different system scans by the data collector. When you sign in, you can choose a target system, compare reports run at different times, and easily see how the system's configuration has changed.
Save configurations
After logging in, you can retrieve past reports, share reports with colleagues, review notifications you received, and retain custom settings. Anonymous users cannot access these features.
Bulk uploader
As a registered user,you can upload multiple reports, using the Bulk Uploader.