This page lists publically-released patches for Veritas Enterprise Products.
For Product GA build, see Veritas Entitlement Management System(VEMS) by clicking the Veritas Support 'Licensing' option.
For information on private patches, contact Veritas Technical Support.
Veritas is making it easier to find all software installers and updates for Veritas products with a completely redesigned experience. NetBackup HotFixes and NetBackup Appliance patches are now also available at the new Veritas Download Center.
Patches for your product can have a variety of names. These names are based on product, component, or package names. For more information on patch naming conventions and the relationship between products, components, and packages, see the SORT online help.
data_insight-win-3.0.1RP4HF15a
Obsolete
The latest patch(es) : data_insight-3.0.1RP4HF15b 
Sign in if you want to rate this patch.

 Basic information
Release type: Hot Fix
Release date: 2013-03-18
OS update support: None
Technote: None
Documentation: None
Popularity: 303 viewed    10 downloaded
Download size: 507.82 KB
Checksum: 4271516524

 Applies to one or more of the following products:
Data Insight 3.0.1 On Windows 32-bit
Data Insight 3.0.1 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch is obsolete. It is superseded by: Release date
data_insight-3.0.1RP4HF15b 2013-04-24

 Fixes the following incidents:
3118904

 Patch ID:
None.

 Readme file  [Save As...]
Date:2013-03-14

OS: Windows

Etrack Incidents: 3118904

Errors/Problems Fixed:

3118904 - Reduce severity level to warning for error:UNKNOWN_LINK.(No longer treating unknown links as errors.)


Applies to: Management Server, Collector nodes and Windows File Servers (if the UNKNOWN_LINK issue is seen for Windows File Server shares).

Install/Uninstall Instructions:

Apply this hotfix to Data Insight Management Server, Collector and Windows File Server nodes. 
This hotfix can be applied to Data Insight version 3.0.1(30RU1) RP4 only.

FILE AFFECTED BY THIS PATCH:

INSTALL_ROOT\DataInsight\bin\scanner.exe
INSTALL_ROOT\DataInsight\pdb\scanner.pdb


By default, value of INSTALL_ROOT on Windows is "C:\Program Files\Symantec".

NOTE: Please keep a backup of the files  you are about to patch. This will be
required in case you want to rollback the patch.

Steps:

	Log into Data Insight server machine with Administrative privileges
	and perform the following steps:

	1. Stop Data Insight services:
		From the command prompt, issue the following command:
		
		net stop DataInsightWatchdog
		net stop DataInsightWeb
		net stop DataInsightHttpd
		net stop DataInsightComm
		net stop DataInsightConfig
	
	2. Take a backup of entire bin\ and pdb\ folders under the install location.

	3. Unzip the patch files to a temporary folder. In this folder, locate the
	"patches" folder. This folder contains binaries for 32bit as well as 64bit Windows operating 
	Systems. Files provided in the patch are in the same directory hierarchy as
	those present on your system at: 
	"INSTALL_ROOT\DataInsight".
	Example: If you unzip hotfix to C:\temp, it will create the following folders 
	under C:\temp:
	C:\TEMP
	+---README
	+---patches
		+---windows
			+---32bit
				+-------bin
				+-------pdb
			+---64bit
				+-------bin
				+-------pdb

	4. Copy the patch files to the install directory. For example, if you are
	patching a 64 bit Windows server installed at "C:\Program Files\Symantec\DataInsight",
	copy entire contents under "C:\temp\patches\64bit" to "C:\Program Files\Symantec\DataInsight",
	replacing the original files with those from the patch.

	5. Start Data Insight services:
	From the command prompt, issue the following command:
	
		net start DataInsightConfig
		net start DataInsightComm
		net start DataInsightHttpd
		net start DataInsightWeb
		net start DataInsightWatchdog

Additional Notes:
Apply this hotfix to Data Insight 3.0.1(30RU1) RP4 only.



Read and accept Terms of Service