data_insight-win-4.5HF2

 Basic information
Release type: Hot Fix
Release date: 2014-08-08
OS update support: None
Technote: None
Documentation: None
Popularity: 3213 viewed    downloaded
Download size: 583.22 KB
Checksum: 3475714475

 Applies to one or more of the following products:
Data Insight 4.5 On Windows 32-bit
Data Insight 4.5 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
3567613

 Patch ID:
None.

Readme file
Date: 2014-08-08

OS: Windows

Etrack Incidents: 3567613 

Errors/Problems Fixed:

3567613 -  scanner.exe crashes while creating snapshot file names.

Applies to: All Data Insight Collector nodes and Windows 
File Server agent nodes.

Install/Uninstall Instructions:

Apply this hotfix to all Data Insight Collector nodes and Windows 
File Server agent nodes. 

This hotfix can be applied to Data Insight version 4.5 only.

FILE AFFECTED BY THIS PATCH:

Windows:
INSTALL_ROOT\DataInsight\bin\scanner.exe
INSTALL_ROOT\DataInsight\pdb\scanner.pdb


By default, value of INSTALL_ROOT on Windows is "C:\Program Files\Symantec".

NOTE: Please keep a backup of the files you are about to patch. This will be 
required in case you want to rollback the patch.

Steps:

Log into Data Insight Collector nodes and Windows File Server agent nodes
	and perform the following steps:
	
	1. Stop Data Insight Communication service:

    	From the command prompt, issue the following command:

        net stop DataInsightComm
	
	2. 	Take a backup of entire bin and pdb folders under the install location.
	   
	3. Unzip the patch files to a temporary folder. In this folder, locate the
	"patches" folder. This folder contains binaries for 64bit and 32 bit 
	Windows operating Systems. 
	Files provided in the patch are in the same directory hierarchy as those 
	present on your system at: "INSTALL_ROOT\DataInsight".
	
	Example: If you unzip hotfix to C:\temp, it will create the following folders 
	under C:\temp:
	C:\TEMP\
	+---README
	+---patches
		+---windows
			+---32bit
				+-------bin
				+-------pdb
			+---64bit
				+-------bin
				+-------pdb

	4. Copy the patch files to the install directory. For example, if you are
	patching a 64 bit Windows server installed at 
	"C:\Program Files\Symantec\DataInsight", copy entire contents under 
	"C:\temp\patches\windows\64bit" to "C:\Program Files\Symantec\DataInsight",
	replacing the original files with those from the patch.

	5. Start Data Insight Communication service:

		From the command prompt, issue the following command:
	
        net start DataInsightComm

Additional Notes:
1. Apply this hotfix to Data Insight 4.5 only.
2. Apply this hotfix only if the issue is present in your environment.