data_insight-win-3.0.1RP9HF20

 Basic information
Release type: Hot Fix
Release date: 2015-01-06
OS update support: None
Technote: None
Documentation: None
Popularity: 304 viewed    downloaded
Download size: 320.42 KB
Checksum: 3734669654

 Applies to one or more of the following products:
Data Insight 3.0.1 On Windows 32-bit
Data Insight 3.0.1 On Windows 64-bit

 Obsolete patches, incompatibilities, superseded patches, or other requirements:
None.

 Fixes the following incidents:
3685662

 Patch ID:
None.

Readme file
Date: 2015-01-06

OS: Windows

Etrack Incidents: 3685662

Errors/Problems Fixed:

3685662 - WhiteList based policies not working if number of values specified is larger.


Applies to: Data Insight Management Server node.

Install/Uninstall Instructions:

Apply this hotfix to Data Insight Management Server node only. 
This hotfix can be applied to Data Insight version 3.0.1(30RU1) RP9 only.

FILES AFFECTED BY THIS PATCH:

INSTALL_ROOT\DataInsight\bin\user.dll
INSTALL_ROOT\DataInsight\pdb\user.pdb


By default, value of INSTALL_ROOT on Windows is "C:\Program Files\Symantec".

NOTE: Please keep a backup of the files  you are about to patch. This will be
required in case you want to rollback the patch.

Steps:

	Log into Data Insight Management Server node with Administrative privileges
	and perform the following steps:

	1. Stop Data Insight services:
		From the command prompt, issue the following command:
		
		net stop DataInsightWatchdog
		net stop DataInsightWeb
		net stop DataInsightHttpd
		net stop DataInsightComm
		net stop DataInsightConfig
	
	2. Take a backup of entire bin\ and pdb\ folders under the install location.

	3. Unzip the patch files to a temporary folder. In this folder, locate the
	"patches" folder. This folder contains binaries for 32bit as well as 64bit Windows operating 
	Systems. Files provided in the patch are in the same directory hierarchy as
	those present on your system at: 
	"INSTALL_ROOT\DataInsight".
	Example: If you unzip hotfix to C:\temp, it will create the following folders 
	under C:\temp:
	C:\TEMP
	+---README
	+---patches
		+---linux
			+---64bit
		+---windows
			+---32bit
				+-------bin
				+-------pdb
			+---64bit
				+-------bin
				+-------pdb

	5. Copy the patch files to the install directory. For example, if you are
	patching a 64 bit Windows server installed at "C:\Program Files\Symantec\DataInsight",
	copy entire contents under "C:\temp\patches\windows\64bit" to "C:\Program Files\Symantec\DataInsight",
	replacing the original files with those from the patch.

	6. Start Data Insight services:
	From the command prompt, issue the following command:
	
		net start DataInsightConfig
		net start DataInsightComm
		net start DataInsightHttpd
		net start DataInsightWeb
		net start DataInsightWatchdog

Additional Notes:
Apply this hotfix to Data Insight 3.0.1(30RU1) RP9 only.