Symantec logo

Rule definitions and attributes

You can use the info keyword to show a description of a rule.

See "Discovering what a rule does" on page 447.

Rule definitions in Storage Expert lists the available rule definitions, and rule attributes and their default values.

Rule definitions in Storage Expert

Rule

Description

vxse_dc_failures 

Checks and points out failed disks and disabled controllers. 

vxse_dg1 

Checks for disk group configurations in which the disk group has become too large. 

vxse_dg2 

Checks for disk group configurations in which the disk group has too many or too few disk group configuration copies, and if the disk group has too many or too few disk group log copies.  

vxse_dg3 

Checks disk group configurations to verify that the disk group has the correct "on disk config" size. 

vxse_dg4 

Checks for disk groups that do not have a current version number, and which may need to be upgraded. 

vxse_dg5 

Checks for disk groups in which there is only one VxVM configured disk. 

vxse_dg6 

Checks for disk groups that are seen, but which are not imported. 

vxse_disk 

Checks for disks that are initialized, but are not part of any disk group. 

vxse_disklog 

Checks for physical disks that have more than one RAID-5 log. 

vxse_drl1 

Checks for large mirror volumes that do not have an associated DRL log. 

vxse_drl2 

Checks for large mirror volumes that do not have DRL log that is mirrored. 

vxse_host 

Checks that the system "hostname" in the /etc/vx/volboot file matches the hostname that was assigned to the system when it was booted. 

vxse_mirstripe 

Checks for large mirror-striped volumes that should be striped-mirrors. 

vxse_raid5 

Checks for RAID-5 volumes that are too narrow or too wide. 

vxse_raid5log1 

Checks for RAID-5 volumes that do not have an associated log. 

vxse_raid5log2 

Checks for recommended minimum and maximum RAID-5 log sizes. 

vxse_raid5log3 

Checks for large RAID-5 volumes that do not have a mirrored RAID-5 log. 

vxse_redundancy 

Checks the redundancy of volumes. 

vxse_rootmir 

Checks that all root mirrors are set up correctly. 

vxse_spares 

Checks that the number of spare disks in a disk group is within the VxVM "Best Practices" thresholds. 

vxse_stripes1 

Checks for stripe volumes whose stripe unit is not a multiple of the default stripe unit size. 

vxse_stripes2 

Checks for stripe volumes that have too many or too few columns. 

vxse_volplex 

Checks for volumes and plexes that are in various states, such as: 

  • disabled plexes
  • detached plexes
  • stopped volumes
  • disabled volumes
  • disabled logs
  • failed plexes
  • volumes needing recovery

You can use the list and check keywords to show what attributes are available for a rule and to display the default values of these attributes.

See "Running a rule" on page 447.

Rule attributes and default attribute values lists the available rule attributes and their default values.

Rule attributes and default attribute values

Rule

Attribute

Default value

Description

vxse_dc_failures 

- 

No user-configurable variables. 

vxse_dg1 

max_disks_per_dg 

250 

Maximum number of disks in a disk group. Warn if a disk group has more disks than this. 

vxse_dg2 

- 

No user-configurable variables. 

vxse_dg3 

- 

No user-configurable variables. 

vxse_dg4 

- 

No user-configurable variables. 

vxse_dg5 

- 

No user-configurable variables. 

vxse_dg6 

- 

No user-configurable variables. 

vxse_disk 

No user-configurable variables. 

vxse_disklog 

No user-configurable variables. 

vxse_drl1 

mirror_threshold 

1g (1GB) 

Large mirror threshold size. Warn if a mirror is larger than this and does not have an attached DRL log. 

vxse_drl2 

large_mirror_size 

20g (20GB) 

Large mirror-stripe threshold size. Warn if a mirror-stripe volume is larger than this. 

vxse_host 

No user-configurable variables. 

vxse_mirstripe 

large_mirror_size




nsd_threshold
 

1g (1GB)




Large mirror-stripe threshold size.
Warn if a mirror-stripe volume is larger than this.

Large mirror-stripe number of subdisks threshold. Warn if a mirror-stripe volume has more subdisks than this. 

vxse_raid5 

too_narrow_raid5




too_wide_raid5
 

4




Minimum number of RAID-5 columns. Warn if actual number of RAID-5 columns is less than this.

Maximum number of RAID-5 columns. Warn if the actual number of RAID-5 columns is greater than this. 

vxse_raid5log1 

No user-configurable variables. 

vxse_raid5log2 

r5_max_size



r5_min_size
 

1g (1GB)



64m (64MB) 

Maximum RAID-5 log check size. Warn if a RAID-5 log is larger than this.

Minimum RAID-5 log check size. Warn if a RAID-5 log is smaller than this. 

vxse_raid5log3 

large_vol_size 

20g (20GB) 

Large RAID-5 volume threshold size. Warn if a RAID-5 volume with a non-mirrored RAID-5 log is larger than this. 

vxse_redundancy 

volume_redundancy 

Volume redundancy check. The value of 2 performs a mirror redundancy check. A value of 1 performs a RAID-5 redundancy check. The default value of 0 performs no redundancy check. 

vxse_rootmir 

- 

No user-configurable variables. 

vxse_spares 

max_disk_spare_ratio




min_disk_spare_ratio
 

20




10 

Maximum percentage of spare disks in a disk group. Warn if the percentage of spare disks is greater than this.

Minimum percentage of spare disks in a disk group. Warn if the percentage of spare disks is less than this. 

vxse_stripes1 

default _stripeunit 

8k (8KB) 

Stripe unit size for stripe volumes. Warn if a stripe does not have a stripe unit which is an integer multiple of this value. 

vxse_stripes2 

too_narrow_stripe




too_wide_stripe
 

3




16 

Minimum number of columns in a striped plex. Warn if a striped volume has fewer columns than this.

Maximum number of columns in a striped plex. Warn if a striped volume has more columns than this. 

vxse_volplex 