Note
The following procedure is suitable for use with any array that is administered by using the Solaris
luxadm
command.
To replace a disk in a Sun StorEdge A5x00 disk array
vxdiskadm
command, and select menu item 4 (Remove a disk for replacement)
from the main men. Enter none
when prompted to name a replacement disk.
where daname is the disk access name of the device (for example, c1t5d0s2
).
luxadm
command to obtain the array name and slot number of the disk, and then use these values with luxadm
to remove the disk:
# luxadm disp /dev/rdsk/
daname
# luxadm remove_device
array_name,
slot_number
Follow the luxadm
prompts, and pull out the disk when instructed.
luxadm
command when you are ready to insert the replacement disk:
# luxadm insert_device
array_name,
slot_number
Follow the luxadm
prompts, and insert the replacement disk when instructed.
5 (Replace a failed or removed disk)
from the main menu, and follow the instructions.