You can specify one or more of the following relayout options to change the default layout configuration:
ncol=number |
Specifies the number of columns. |
ncol=+number |
Specifies the number of columns to add. |
ncol=-number |
Specifies the number of columns to remove. |
stripeunit=size |
Specifies the stripe width. |
The following examples use vxassist to change the stripe width and number of columns for a striped volume in the disk group dbasedg:
# vxassist -g dbasedg relayout vol03 stripeunit=64k ncol=6 # vxassist -g dbasedg relayout vol03 ncol=+2 # vxassist -g dbasedg relayout vol03 stripeunit=128k
The following example changes a concatenated volume to a RAID-5 volume with four columns:
# vxassist -g dbasedg relayout vol04 layout=raid5 ncol=4