Verifying GAB

Verify the GAB operation using the gabconfig -a command. This command returns the GAB port membership information.

The ports indicate the following:

a

GAB

b

I/O fencing

d

Oracle Disk Manager (ODM)

f

Cluster File System (CFS)

h

Veritas Cluster Server (VCS: High Availability Daemon)

u

Cluster Volume Manager (CVM)

(to ship commands from slave node to master node)

Port u in the gabconfig output is visible with CVM protocol version >= 100.

v

Cluster Volume Manager (CVM)

w

vxconfigd (module for CVM)

y

Cluster Volume Manager (CVM) I/O shipping

For more information on GAB, refer to the Veritas Cluster Server Administrator's Guide.

To verify GAB

  1. To verify that GAB operates, type the following command on each node:
    /sbin/gabconfig -a
  2. Review the output of the command:

    • If GAB operates, the following GAB port membership information is returned:

      GAB Port Memberships
      ===================================
      Port a gen  ada401 membership 01
      Port b gen  ada40d membership 01
      Port d gen  ada409 membership 01
      Port f gen  ada41c membership 01
      Port h gen  ada40f membership 01
      Port u gen  ada41a membership 01
      Port v gen  ada416 membership 01
      Port w gen  ada418 membership 01
      Port y gen  ada42a membership 01

      Note that port b in the gabconfig command output may not indicate that I/O fencing feature is configured. After you configure SFCFSHA using the installer, the installer starts I/O fencing in disabled mode. You can use the vxfenadm -d command to verify the I/O fencing configuration.

    • If GAB does not operate, the command does not return any GAB port membership information:

          GAB Port Memberships
          ===================================