Verify the GAB operation using the gabconfig -a command. This command returns the GAB port membership information.
The ports indicate the following:
For more information on GAB, refer to the Veritas Cluster Server Administrator's Guide.
To verify GAB
/sbin/gabconfig -a
Review the output of the command:
If GAB operates, the following GAB port membership information is returned:
GAB Port Memberships =================================== Port a gen ada401 membership 01 Port b gen ada40d membership 01 Port d gen ada409 membership 01 Port f gen ada41c membership 01 Port h gen ada40f membership 01 Port u gen ada41a membership 01 Port v gen ada416 membership 01 Port w gen ada418 membership 01 Port y gen ada42a membership 01
Note that port b in the gabconfig command output may not indicate that I/O fencing feature is configured. After you configure SFCFSHA using the installer, the installer starts I/O fencing in disabled mode. You can use the vxfenadm -d command to verify the I/O fencing configuration.
If GAB does not operate, the command does not return any GAB port membership information:
GAB Port Memberships ===================================