After the SmartIO feature is configured, you can verify that the cache area is present and that caching is occurring.
To verify and monitor the cache area
# sfcache list -l
Cachearea: sfcachearea_1 Assoc Type: AUTO Type: VxVM Size: 30.00g Cacheline Size: 64.00k Memory Size: 16.00m State: ONLINE Layout: CONCAT Number of Columns: 0 ASSOCIATED DATA OBJECTS: Volume: testdg/testvol1 Size: 500.00g State: ENABLED Kstate: ENABLED Caching Mode: read Volume: testdg/testvol2 Size: 500.00g State: ENABLED Kstate: ENABLED Caching Mode: read
# sfcache list sfcachearea_1 Cachearea: sfcachearea_1 Assoc Type: AUTO Type: VxVM Size: 30.00g Cacheline Size: 64.00k Memory Size: 16.00m State: ONLINE Layout: CONCAT Number of Columns: 0 ASSOCIATED DATA OBJECTS: ASSOC DATAOBJECT NAME CACHING-MODE STATE KSTATE testdg/testvol1 read ENABLED ENABLED testdg/testvol2 read ENABLED ENABLED
# sfcache stat sfcachearea_1
HIT RATIO ART(Hit)ms ART(Miss)ms BYTES NAME %CACHE RD WR RD WR RD WR RD WR TYPE: VxVM sfcachearea_1 13.43 91.24 94.20 0.142 0.819 0.414 0.798 15.31g 4.21g ASSOCIATED DATA OBJECTS: testdg/testvol1 6.10 90.00 96.00 0.141 0.459 0.348 0.448 6.77g 1.89g testdg/testvol2 7.32 91.00 92.00 0.143 1.179 0.480 1.149 8.54g 2.31g