Displaying consolidated information about the DMP nodes

The vxdmpadm list dmpnode command displays the detail information of a Dynamic Multi-Pathing (DMP) node. The information includes the enclosure name, LUN serial number, port id information, device attributes, and so on.

The following command displays the consolidated information for all of the DMP nodes in the system:

# vxdmpadm list dmpnode all

Use the enclosure attribute with list dmpnode to obtain a list of all DMP nodes for the specified enclosure.

# vxdmpadm list dmpnode enclosure=enclosurename

For example, the following command displays the consolidated information for all of the DMP nodes in the enc0 enclosure.

# vxdmpadm list dmpnode enclosure=enc0

Use the dmpnodename attribute with list dmpnode to display the DMP information for a given DMP node. The DMP node can be specified by name or by specifying a path name. The detailed information for the specified DMP node includes path information for each subpath of the listed DMP node.

The path state differentiates between a path that is disabled due to a failure and a path that has been manually disabled for administrative purposes. A path that has been manually disabled using the vxdmpadm disable command is listed as disabled(m).

# vxdmpadm list dmpnode dmpnodename=dmpnodename

For example, the following command displays the consolidated information for the DMP node emc_clariion0_158.

# vxdmpadm list dmpnode dmpnodename=emc_clariion0_158
dmpdev      = emc_clariion0_158
state       = enabled
enclosure   = emc_clariion0
cab-sno     = CK200070400359
asl         = libvxCLARiiON.so
vid         = DGC
pid         = DISK
array-name  = EMC_CLARiiON
array-type  = CLR-A/PF
iopolicy    = MinimumQ
avid        = 158
lun-sno     = 600601601A141B001D4A32F92B49DE11
udid        = DGC%5FDISK%5FCK200070400359%5F600601601A141B001D4A32F92B49DE11
dev-attr    = lun
###path     = name state type transport ctlr hwpath aportID aportWWN attr
path        = sdck enabled(a) primary FC c2 c2 A5 50:06:01:61:41:e0:3b:33 -
path        = sdde enabled(a) primary FC c2 c2 A4 50:06:01:60:41:e0:3b:33 -
path        = sdcu enabled secondary FC c2 c2 B4 50:06:01:68:41:e0:3b:33 -
path        = sdbm enabled secondary FC c3 c3 B4 50:06:01:68:41:e0:3b:33 -
path        = sdbw enabled(a) primary FC c3 c3 A4 50:06:01:60:41:e0:3b:33 -
path        = sdbc enabled(a) primary FC c3 c3 A5 50:06:01:61:41:e0:3b:33 -