Verifying I/O fencing configuration

Verify from the vxfenadm output that the SCSI-3 disk policy reflects the configuration in the /etc/vxfenmode file.

To verify I/O fencing configuration

  1. On one of the nodes, type:
    # vxfenadm -d

    Output similar to the following appears if the fencing mode is SCSI3 and the SCSI3 disk policy is dmp:

    I/O Fencing Cluster Information:
    ================================
    
    Fencing Protocol Version: 201
    Fencing Mode: SCSI3
    Fencing SCSI3 Disk Policy: dmp
    Cluster Members:
    
       * 0 (sys1)
       1 (sys2)
    
    RFSM State Information:
       node 0 in state 8 (running)
       node 1 in state 8 (running)
  2. Verify that the disk-based I/O fencing is using the specified disks.

    # vxfenconfig -l