This section describes steps to configure notification.
To configure notification
You can configure VCS to generate SNMP (V2) traps on a designated server and send emails to designated recipients in response to certain events.
Do the following:
Click a field in the SNMP Console column and type the name or IP address of the console.
The specified SNMP console must be MIB 2.0 compliant.
Click the corresponding field in the Severity column and select a severity level for the console.
Click the + icon to add a field; click the - icon to remove a field.
Enter an SNMP trap port. The default value is 162.
Do the following:
Type the name of the SMTP server.
Click a field in the Recipients column and enter a recipient for notification. Enter recipients as admin@example.com.
Click the corresponding field in the Severity column and select a severity level for the recipient.
VCS sends messages of an equal or higher severity to the recipient.
Click the + icon to add fields; click the - icon to remove a field.
Do the following:
If the cluster has a ClusterService group configured, you can use the NIC resource configured in that service group or configure a new NIC resource for notification.
If you choose to configure a new NIC resource, select a network adapter for each node in the cluster.
The wizard lists the public network adapters along with the adapters that were assigned a low priority.