Specifies a comment that is displayed against the SFW objects such as a volume, plex, subdisk, disk media, and disk group. These comments are useful if you want to display some additional information for these objects. The comment size cannot exceed 40 bytes.
|
Primary
|
Specifies a boolean value true or false.
If set to true, then the RVG is considered the Primary RVG and writes to this RVG are replicated to any RLINK with which it is associated and attached. If set to false (default), then the RVG is a Secondary RVG and receives writes from the Primary RVG.
Note: |
Before setting this attribute, ensure that the RVG is stopped, that is, data access has been disabled. |
|
synchronous
|
Specifies the mode of replication.
|
Rsrlprot
|
Enables or disables log protection.
|
latencyprot
|
Enables or disables latency protection.
|
latency_high_mark
|
Specifies the maximum number of outstanding requests that are allowed when latency protection is enabled.
|
latency_low_mark
|
Specifies a value such that when the writes are stalled, the number of outstanding requests must drop to this value before latency protection can be disabled.
|
local_host
|
Specifies the name or IP address of the local host.
|
remote_host
|
Specifies the name or IP address of the remote host.
|
packet_size
|
Specifies the size of packets in which data can be sent through the network during replication.
|
bandwidth_limit
|
Specifies a value that can be used to control the bandwidth that Volume Replicator needs to use for replication. If this attribute is not specified, then by default, Volume Replicator uses the entire available bandwidth for replication. To disable bandwidth throttling, set this attribute to none. Note that the specified bandwidth value must be at least 1 Mbps (Megabits per second). You can specify the value in units of Kbps, Mbps, Gbps, or bps. The default is Kbps. If no value is specified then bandwidth throttling is disabled.
|
protocol
|
Specifies the protocol to be used for replication between the Primary and Secondary. Specify TCP or UDP.
If the setup includes a Bunker Secondary and replication is over IP, the protocol can be set to UDP or TCP. The default is UDP.
If the storage at the Bunker Secondary is directly accessible from the Primary, for example, DAS or NAS, use the STORAGE protocol, otherwise use TCP/IP or UDP/IP
Note: |
If the replication protocol for the Bunker Secondary has been set to STORAGE then you can change it only by deleting and recreating the Bunker with the required protocol; UDP/IP or TCP/IP. You cannot change the STORAGE protocol using the Change Replication Settings option. |
|
remote_rlink
|
Specifies the name of the remote RLINK.
|
remote_dg
|
Specifies the disk group name of the remote RLINK.
|