README VERSION : 1.1 README CREATION DATE : 2015-11-24 PATCH-ID : 7.0.1.0 PATCH NAME : VRTSsfcpi BASE PACKAGE NAME : VRTSsfcpi BASE PACKAGE VERSION : 7.0.0.0 SUPERSEDED PATCHES : NONE REQUIRED PATCHES : NONE INCOMPATIBLE PATCHES : NONE SUPPORTED PADV : sol11_x64 (P-PLATFORM , A-ARCHITECTURE , D-DISTRIBUTION , V-VERSION) PATCH CATEGORY : PATCH CRITICALITY : RECOMMENDED HAS KERNEL COMPONENT : NO ID : NONE REBOOT REQUIRED : NO REQUIRE APPLICATION DOWNTIME : NO PATCH INSTALLATION INSTRUCTIONS: -------------------------------- Please refer the release notes for installation instructions. PATCH UNINSTALLATION INSTRUCTIONS: ---------------------------------- Please refer the release notes for un-installation instructions. SPECIAL INSTRUCTIONS: --------------------- NONE SUMMARY OF FIXED ISSUES: ----------------------------------------- PATCH ID:7.0.1.0 3781993 (3852238) Asynchronous Monitoring Framework (AMF) process may fail to be stopped after upgrade. 3806206 (3806690) After upgrade from 6.X to 7.0, Notify sink and application resource go into OFFLINE| UNKNOWN state. SUMMARY OF KNOWN ISSUES: ----------------------------------------- NONE KNOWN ISSUES : -------------- NONE FIXED INCIDENTS: ---------------- PATCH ID:7.0.1.0 * INCIDENT NO:3781993 TRACKING ID:3852238 SYMPTOM: The installer fails to stop AMF process because the AMF module cannot be unloaded. DESCRIPTION: During package/patch upgrade, AMF SMF service is enabled but fails to be disabled. This causes CPI to be unable to stop AMF because AMF module is in use. RESOLUTION: During upgrade, the installer will use a workaround to disable AMF SMF service with command: svcadm disable -s system/amf By using this command, AMF SMF service keeps in disabled state during package upgrade. * INCIDENT NO:3806206 TRACKING ID:3806690 SYMPTOM: After upgrade from 6.X to 7.0, Notify sink and application resource go into OFFLINE| UNKNOWN state if it is configured using the wizards. DESCRIPTION: The 7.0 paths of some binaries have changed. "/opt/VRTSvcs/portal/admin/notify_sink" is changed to "/opt/VRTSvcs/portal/vcs_wizards/admin/notify_sink". "/opt/VRTSvcs/bin/Application/getServiceStatus" is changed to "/opt/VRTSvcs/bin/Application/getServiceStatus.wiz". Due to this, if any resource uses any of these paths, they would report UNKNOWN state. RESOLUTION: The installer performs the following path changes during upgrade procedure in VCS configuration file: (1) Change the binary path from "/opt/VRTSvcs/portal/admin/notify_sink" to "/opt/VRTSvcs/portal/vcs_wizards/admin/notify_sink". (2) Change the binary path from "/opt/VRTSvcs/bin/Application/getServiceStatus" to "/opt/VRTSvcs/bin/Application/getServiceStatus.wiz". INCIDENTS FROM OLD PATCHES: --------------------------- NONE