infoscale-sol11_sparc-Patch-7.4.1.2300

 Basic information
Release type: Patch
Release date: 2022-01-16
OS update support: Solaris 11 SPARC Update 4
Technote: None
Documentation: None
Popularity: 524 viewed    downloaded
Download size: 420.98 MB
Checksum: 2814123581

 Applies to one or more of the following products:
InfoScale Availability 7.4.1 On Solaris 11 SPARC
InfoScale Enterprise 7.4.1 On Solaris 11 SPARC
InfoScale Foundation 7.4.1 On Solaris 11 SPARC
InfoScale Storage 7.4.1 On Solaris 11 SPARC

 Obsolete patches, incompatibilities, superseded patches, or other requirements:

This patch supersedes the following patches: Release date
vm-sol11_sparc-Patch-7.4.1.2600 (obsolete) 2020-09-11
infoscale-sol11_sparc-Patch-7.4.1.1100 (obsolete) 2020-03-16
dbed-sol11_sparc-Patch-7.4.1.1100 (obsolete) 2020-01-23
vcsea-sol11_sparc-Patch-7.4.1.1100 (obsolete) 2020-01-22
vcs-sol11_sparc-Patch-7.4.1.1100 (obsolete) 2019-11-05

 Fixes the following incidents:
3968739, 3980547, 3982248, 3982912, 3984156, 3984165, 3985796, 3986554, 3996796, 4001757, 4005540, 4006949, 4008748, 4010517, 4010520, 4011097, 4013643, 4016876, 4017284, 4022943, 4026389, 4033162, 4039525, 4039526, 4039527, 4042947, 4045494, 4047722, 4049416, 4050229, 4050664, 4050892, 4051040, 4051815, 4051887, 4051889, 4051896, 4053149, 4054243, 4054244, 4054264, 4054265, 4054266, 4054267, 4054269, 4054270, 4054271, 4054272, 4054273, 4054276, 4054323, 4054325, 4054387, 4054412, 4054416, 4054481, 4054697, 4054724, 4054725, 4054726, 4055653, 4055660, 4055668, 4055697, 4055772, 4055858, 4055895, 4055899, 4055905, 4055925, 4055938, 4056107, 4056124, 4056146, 4056567, 4056779, 4056918, 4057208

 Patch ID:
None.

Readme file
                          * * * READ ME * * *
                      * * * InfoScale 7.4.1 * * *
                         * * * Patch 2300 * * *
                         Patch Date: 2021-11-25


This document provides the following information:

   * PATCH NAME
   * OPERATING SYSTEMS SUPPORTED BY THE PATCH
   * PACKAGES AFFECTED BY THE PATCH
   * BASE PRODUCT VERSIONS FOR THE PATCH
   * SUMMARY OF INCIDENTS FIXED BY THE PATCH
   * DETAILS OF INCIDENTS FIXED BY THE PATCH
   * INSTALLATION PRE-REQUISITES
   * INSTALLING THE PATCH
   * REMOVING THE PATCH
   * KNOWN ISSUES


PATCH NAME
----------
InfoScale 7.4.1 Patch 2300


OPERATING SYSTEMS SUPPORTED BY THE PATCH
----------------------------------------
Solaris 11 SPARC


PACKAGES AFFECTED BY THE PATCH
------------------------------
VRTSamf
VRTScavf
VRTSdbed
VRTSgab
VRTSllt
VRTSodm
VRTSperl
VRTSpython
VRTSsfmh
VRTSvcs
VRTSvcsag
VRTSvcsea
VRTSvlic
VRTSvxfen
VRTSvxfs
VRTSvxvm


BASE PRODUCT VERSIONS FOR THE PATCH
-----------------------------------
   * InfoScale Availability 7.4.1
   * InfoScale Enterprise 7.4.1
   * InfoScale Foundation 7.4.1
   * InfoScale Storage 7.4.1


SUMMARY OF INCIDENTS FIXED BY THE PATCH
---------------------------------------
Patch ID: VRTSvcsag-7.4.1.1200
* 4042947 (4042944) In a hardware replication environment, a disk group resource may fail to be imported when the HARDWARE_MIRROR flag is set.
* 4054269 (4030215) The InfoScale agents for Azure agents did not support credential validation methods based on the azure-identity library.
* 4054270 (4046286) The InfoScale agents for Azure do not handle generic exceptions.
* 4054273 (4044567) The HostMonitor agent faults while logging the memory usage of a system.
* 4054276 (4048164) When a cloud API that an InfoScale agent has called hangs, an unwanted failover of the associated service group may occur.
Patch ID: VRTSvcsag-7.4.1.1100
* 3996796 (3996795) After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state.
Patch ID: VRTSdbed-7.4.1.1100
Patch ID: VRTSperl-5.26.1.3
* 3985796 (3985793) The NFS and the RVGPrimary agents failed to find their respective Perl modules.
Patch ID: VRTSvxvm-7.4.1.3300
* 3984156 (3852146) A shared disk group (DG) fails to be imported when "-c" and "-o noreonline" are specified together.
* 4001757 (3969387) VxVM(Veritas Volume Manager) caused system panic when handle received request response in FSS environment.
* 4011097 (4010794) When storage activity was going on, Veritas Dynamic Multi-Pathing (DMP) caused system panic in a cluster.
* 4013643 (4010207) System panicked due to hard-lockup due to a spinlock not released properly during the vxstat collection.
* 4017284 (4011691) High CPU consumption on the VVR secondary nodes because of high pending IO load.
* 4022943 (4017656) Add support for XP8 arrays in the current ASL.
* 4033162 (3968279) Vxconfigd dumping core for NVME disk setup.
* 4039525 (4012763) I/O may hang in a Veritas Volume Replicator (VVR) configuration when the SRL overflows for one rlink while another rlink is in the AUTOSYNC mode.
* 4039526 (4034616) vol_seclog_limit_ioload tunable needs to be enabled on Linux only.
* 4039527 (4018086) The system hangs when the RVG in DCM resync with SmartMove is set to ON.
* 4045494 (4021939) The "vradmin syncvol" command fails due to recent changes related to binding sockets without specifying IP addresses.
* 4047722 (4023390) Vxconfigd keeps dump core as invalid private region offset on a disk.
* 4050892 (3991668) In a Veritas Volume Replicator (VVR) configuration where secondary logging is enabled, data inconsistency is reported after the "No IBC message arrived" error is encountered.
* 4051815 (4031597) vradmind generates a core dump in __strncpy_sse2_unaligned.
* 4051887 (3956607) A core dump occurs when you run the vxdisk reclaim command.
* 4051889 (4019182) In case of a VxDMP configuration, an InfoScale server panics when applying a patch.
* 4051896 (4010458) In a Veritas Volume Replicator (VVR) environment, the rlink might inconsistently disconnect due to unexpected transactions.
* 4055653 (4049082) I/O read error is displayed when remote FSS node rebooting.
* 4055660 (4046007) The private disk region gets corrupted if the cluster name is changed in FSS environment.
* 4055668 (4045871) vxconfigd crashed at ddl_get_disk_given_path.
* 4055697 (4047793) Unable to import diskgroup even replicated disks are in SPLIT mode
* 4055772 (4043337) logging fixes for VVR
* 4055895 (4038865) The system panics due to deadlock between inode_hash_lock and DMP shared lock.
* 4055899 (3993242) vxsnap prepare command when run on vset sometimes fails.
* 4055905 (4052191) Unexcepted scripts or commands are run due to an incorrect comments format in the vxvm-configure script.
* 4055925 (4031064) Master switch operation is hung in VVR secondary environment.
* 4055938 (3999073) The file system corrupts when the cfsmount group goes into offline state.
* 4056107 (4036181) Volumes that are under a RVG (Replicated Volume Group), report an IO error.
* 4056124 (4008664) System panic when signal vxlogger daemon that has ended.
* 4056146 (3983832) VxVM commands hang in CVR environment.
* 4056918 (4056917) Import of disk group in Flexible Storage Sharing (FSS) with missing disks can lead to data corruption.
* 4057208 (4053864) The swap/dump method failed to start because of underlying dmp nodes not being ready.
Patch ID: VRTSvxvm-7.4.1.2600
* 3968739 (3968334) Solaris 11.4: Appropriate library VRTS_vxvm_link.so is not copied on the system after OS upgrade.
* 3984165 (3982817) Appropriate modules are not loaded on the system during fresh installation of InfoScale on Solaris 11.4 system
* 4005540 (3970627) vxstat command shows incorrect data for IO Operations.
* 4006949 (4006539) zpool corruption occurs when DMP(Dynamic Multipathing) Native Support is enabled on two servers at the same time.
* 4008748 (3989185) In a Veritas Volume Manager(VVR) environment vxrecover command can hang.
* 4010517 (3998475) Unmapped PHYS read I/O split across stripes gives incorrect data leading to data corruption.
* 4010520 (4003805) Panic encountered when using Oracle with mirrored volumes and DCOs on IS 7.4.1/Sol11.4
Patch ID: VRTSllt-7.4.1.1100
* 4050664 (4046199) LLT configurations over UDP accept only ethernet interface names as link tag names.
* 4051040 (3989372) When the CPU load and memory consumption is high in a VMware environment, some nodes in an InfoScale cluster may get fenced out.
* 4054272 (4045607) Performance improvement of the UDP multiport feature of LLT on 1500 MTU-based networks.
* 4054697 (3985775) Sometimes, the system log may get flooded with LLT heartbeat loss messages that do not necessarily indicate any actual issues with LLT.
Patch ID: VRTSgab-7.4.1.1100
* 4054264 (4046413) After a node is added to or removed from a cluster, the GAB node count or the fencing quorum is not updated.
* 4054265 (4046418) The GAB module starts up even if LLT is not configured.
Patch ID: VRTSamf-7.4.1.1100
* 4054323 (4001565) On Solaris 11.4, IMF fails to provide notifications when Oracle processes stop.
Patch ID: VRTSvxfen-7.4.1.1200
* 4016876 (4000745) The VxFEN process fails to start due to late discovery of the VxFEN disk group.
Patch ID: VRTSvxfen-7.4.1.1100
* 3986554 (3986553) After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state.
Patch ID: VRTSvcs-7.4.1.1200
* 4054266 (4040705) When a command exceeds 4096 characters, hacli hangs indefinitely.
* 4054267 (4040656) When the ENOMEM error occurs, HAD does not shut down gracefully.
* 4054271 (4043700) In case of failover, parallel, or hybrid service groups, multiple PreOnline triggers can be executed on the same node or on different nodes in a cluster while an online operation is in already progress.
Patch ID: VRTSvcs-7.4.1.1100
* 3982912 (3981992) A potentially critical security vulnerability in VCS needs to be addressed.
Patch ID: VRTSvcsea-7.4.1.1200
* 4054325 (4043289) In an Oracle ASM 19c environment on Solaris, the ASMInst agent fails to come online or to detect the state of the related resources.
* 3982248 (3989510) The VCS agent for Oracle does not support Oracle 19c databases.
Patch ID: VRTScavf-7.4.1.3400
* 4056567 (4054462) In a hardware replication environment, a shared disk group resource may fail to be imported when the HARDWARE_MIRROR flag is set.
Patch ID: VRTSvlic-4.01.741.300
* 4049416 (4049416) Migrate Licensing Collector service from Java to Python.
Patch ID: VRTSpython-3.6.6.10
* 4056779 (4049771) The VRTSpython package needs to be made available on AIX and Solaris to support the InfoScale licensing component.
Patch ID: VRTSvxfs-7.4.1.3400
* 4026389 (4026388) Unable to unpin a file back after pinning while testing SMARTIO.
* 4050229 (4018995) Panic in AIX while doing read ahead of size greater than 4 GB.
* 4053149 (4043084) panic in vx_cbdnlc_lookup
* 4054243 (4014274) Gsed cmd might report a bad address error
* 4054244 (4052449) Cluster goes in an 'unresponsive' mode while invalidating pages due to duplicate page entries in iowr structure.
* 4054387 (4054386) If systemd service fails to load vxfs module, the service still shows status as active instead of failed.
* 4054412 (4042254) A new feature has been added in vxupgrade which fails disk-layout upgrade if sufficient space is not available in the filesystem.
* 4054416 (4005620) Internal counter of inodes from Inode Allocation Unit (IAU) can be negative if IAU is marked bad.
* 4054724 (4018697) After installing InfoScale 7.4.2, the system fails to start.
* 4054725 (4051108) While storing multiple attributes for a file in an immediate area of inode, system might be unresponsive due to a wrong loop increment statement.
* 4054726 (4051026) If file system is created with inode size 512, the file system might report inconsistencies with the bitmap after running fsck .
* 4055858 (4042925) Intermittent Performance issue on commands like df and ls.
Patch ID: VRTSodm-7.4.1.3400
* 4054481 (4021566) VxODM service fails to start due to a race between odm-run-once and vxodm service.


DETAILS OF INCIDENTS FIXED BY THE PATCH
---------------------------------------
This patch fixes the following incidents:

Patch ID: VRTSvcsag-7.4.1.1200

* 4042947 (Tracking ID: 4042944)

SYMPTOM:
In a hardware replication environment, a disk group resource may fail to be imported when the HARDWARE_MIRROR flag is set.

DESCRIPTION:
After the VCS hardware replication agent resource fails over control to the secondary site, the DiskGroup agent does not rescan all the required device paths in case of a multi-pathing configuration. The vxdg import operation fails, because the hardware device characteristics for all the paths are not refreshed.

RESOLUTION:
A new resource-level attribute, ScanDisks, is introduced for the DiskGroup agent. The ScanDisks attribute lets you perform a selective devices scan for all the disk paths that are associated with a VxVM disk group. Before attempting to import a hardware clone or a hardware replicated device, the VxVM and the DMP attributes of a disk are refreshed. The default value of ScanDisks is 0, which indicates that a selective device scan is not performed. Even when ScanDisks is set to 0, if the disk group fails with an error string containing HARDWARE_MIRROR during the first disk group import attempt, the DiskGroup agent performs a selective device scan to increase the chances of a successful import.
Sample resource configuration for hardware clone disk groups:
DiskGroup tc_dg (
DiskGroup = datadg
DGOptions = "-o useclonedev=on -o updateid"
ForceImport = 0
ScanDisks = 1
)
Sample resource configuration for hardware replicated disk groups:
DiskGroup tc_dg (
DiskGroup = datadg
ForceImport = 0
ScanDisks = 1
)

* 4054269 (Tracking ID: 4030215)

SYMPTOM:
The InfoScale agents for Azure agents did not support credential validation methods based on the azure-identity library.

DESCRIPTION:
The Microsoft Azure credential system is revamped, and the new system is available in the azure-identity library.

RESOLUTION:
The InfoScale agents for Azure have been enhanced to support credential validation methods based on the azure-identity library. Now, the agents support the following Azure Python SDK versions:
azure-common==1.1.25
azure-core==1.10.0
azure-identity==1.4.1
azure-mgmt-compute==19.0.0
azure-mgmt-core==1.2.2
azure-mgmt-dns==8.0.0
azure-mgmt-network==17.1.0
azure-storage-blob==12.8.0
msrestazure==0.6.4

* 4054270 (Tracking ID: 4046286)

SYMPTOM:
The InfoScale agents for Azure do not handle generic exceptions.

DESCRIPTION:
The InfoScale agents can handle only the CloudError exception of the Azure APIs. It cannot handle other errors that may occur during certain failure conditions.

RESOLUTION:
The InfoScale agents for Azure are enhanced to handle several API failure conditions.

* 4054273 (Tracking ID: 4044567)

SYMPTOM:
The HostMonitor agent faults while logging the memory usage of a system.

DESCRIPTION:
The HostMonitor agent runs in the background to monitor the usage of the resources of a system. It faults and terminates unexpectedly while logging the memory usage of a system and generates a core dump.

RESOLUTION:
This patch updates the HostMonitor agent to handle the issue that it encounters while logging the memory usage data of a system.

* 4054276 (Tracking ID: 4048164)

SYMPTOM:
When a cloud API that an InfoScale agent has called hangs, an unwanted failover of the associated service group may occur.

DESCRIPTION:
When a cloud SDK API or a CLI command hangs, the monitor function of an InfoScale agent that has called the API or the command may time out. Consequently, the agent may report incorrect resource states, and an unwanted failover of the associated service group may occur.

RESOLUTION:
To avoid this issue, the default value of the FaultOnMonitorTimeout attribute is set to 0 for all the InfoScale agents for cloud support.

Patch ID: VRTSvcsag-7.4.1.1100

* 3996796 (Tracking ID: 3996795)

SYMPTOM:
After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state.

DESCRIPTION:
This issue occurs when the CoordPoint agent is upgraded to 7.4.1 from any earlier version using a rolling upgrade. A field was added to the VXFEN driver structure due to which the client, VXFEN_IOC_GET_COORD IOCTL, fails.

RESOLUTION:
This hotfix addresses the issue by building the VRTSvcsag module with the updated VxFEN structure.

Patch ID: VRTSdbed-7.4.1.1100

* 3980547 (Tracking ID: 3989826)

SYMPTOM:
Oracle 19c does not support for DBED.

DESCRIPTION:
Oracle 19c does not support for DBED.

RESOLUTION:
Oracle 19c support is enabled for DBED.

Patch ID: VRTSperl-5.26.1.3

* 3985796 (Tracking ID: 3985793)

SYMPTOM:
The NFS and the RVGPrimary agents failed to find their respective Perl modules.

DESCRIPTION:
Recent changes to the VRTSperl module caused the current directory (denoted by ".") to be excluded from the search path environment variable, @INC. The NFS and the RVGPrimary agents failed to find their respective Perl modules, because they are located in the current directory of the respective agent. The current directory was excluded from the search list, because it was not present in the @INC variable.

RESOLUTION:
The directory paths for the NFS and the RVGPrimary agents are added in the @INC variable so that the respective agents can search those locations and find the required files.

Patch ID: VRTSvxvm-7.4.1.3300

* 3984156 (Tracking ID: 3852146)

SYMPTOM:
In a CVM cluster, when a shared DG is imported by specifying both, the "-c" and the "-o noreonline" options, you may encounter the following error: 
VxVM vxdg ERROR V-5-1-10978 Disk group <disk_group_name>: import failed: Disk for disk group not found.

DESCRIPTION:
The "-c" option updates the disk ID and the DG ID on the private region of the disks in the DG that is being imported. Such updated information is not yet seen by the slave because the disks have not been brought online again because the "noreonline" option was specified. As a result, the slave cannot identify the disk(s) based on the updated information sent from the master, which caused the import to fail with the error: Disk for disk group not found.

RESOLUTION:
VxVM is updated so that a shared DG import completes successfully even when the "-c" and the "-o noreonline" options are specified together.

* 4001757 (Tracking ID: 3969387)

SYMPTOM:
In FSS(Flexible Storage Sharing) environment, system might panic with below stack:
vol_get_ioscb [vxio]
vol_ecplex_rhandle_resp [vxio]
vol_ioship_rrecv [vxio]
gab_lrrecv [gab]
vx_ioship_llt_rrecv [llt]
vx_ioship_process_frag_packets [llt]
vx_ioship_process_data [llt]
vx_ioship_recv_data [llt]

DESCRIPTION:
In certain scenario, it may happen that request got purged and response came after that. Then system might panic due to access the freed resource.

RESOLUTION:
Code changes have been made to fix the issue.

* 4011097 (Tracking ID: 4010794)

SYMPTOM:
Veritas Dynamic Multi-Pathing (DMP) caused system panic in a cluster with below stack when storage activities were going on:
dmp_start_cvm_local_failover+0x118()
dmp_start_failback+0x398()
dmp_restore_node+0x2e4()
dmp_revive_paths+0x74()
gen_update_status+0x55c()
dmp_update_status+0x14()
gendmpopen+0x4a0()

DESCRIPTION:
The system panic occurred due to invalid dmpnode's current primary path when disks were attached/detached in a cluster. When DMP accessed the current primary path without doing sanity check, the system panics due to an invalid pointer.

RESOLUTION:
Code changes have been made to avoid accessing any invalid pointer.

* 4013643 (Tracking ID: 4010207)

SYMPTOM:
System panic occurred with the below stack:

native_queued_spin_lock_slowpath()
queued_spin_lock_slowpath()
_raw_spin_lock_irqsave()
volget_rwspinlock()
volkiodone()
volfpdiskiodone()
voldiskiodone_intr()
voldmp_iodone()
bio_endio()
gendmpiodone()
dmpiodone()
bio_endio()
blk_update_request()
scsi_end_request()
scsi_io_completion()
scsi_finish_command()
scsi_softirq_done()
blk_done_softirq()
__do_softirq()
call_softirq()

DESCRIPTION:
As part of collecting the IO statistics collection, the vxstat thread acquires a spinlock and tries to copy data to the user space. During the data copy, if some page fault happens, then the thread would relinquish the CPU and provide the same to some other thread. If the thread which gets scheduled on the CPU requests the same spinlock which vxstat thread had acquired, then this results in a hard lockup situation.

RESOLUTION:
Code has been changed to properly release the spinlock before copying out the data to the user space during vxstat collection.

* 4017284 (Tracking ID: 4011691)

SYMPTOM:
Observed high CPU consumption on the VVR secondary nodes because of high pending IO load.

DESCRIPTION:
High replication related IO load on the VVR secondary and the requirement of maintaining write order fidelity with limited memory pools created  contention. This resulted in multiple VxVM kernel threads contending for shared resources and there by increasing the CPU consumption.

RESOLUTION:
Limited the way in which VVR consumes its resources so that a high pending IO load would not result into high CPU consumption.

* 4022943 (Tracking ID: 4017656)

SYMPTOM:
This is new array and we need to add support for claiming XP8 arrays.

DESCRIPTION:
XP8 is new array and current ASL doesn't support it. So it will not be claimed with current ASL. This array support has been now added in the current ASL.

RESOLUTION:
Code changes to support XP8 array have been done.

* 4033162 (Tracking ID: 3968279)

SYMPTOM:
Vxconfigd dumps core with SEGFAULT/SIGABRT on boot for NVME setup.

DESCRIPTION:
For NVME setup, vxconfigd dumps core while doing device discovery as the data structure is accessed by multiple threads and can hit a race condition. For sector size other than 512, the partition size mismatch is seen because we are doing comparison with partition size from devintf_getpart() and it is in sector size of the disk. This can lead to call of NVME device discovery.

RESOLUTION:
Added mutex lock while accessing the data structure so as to prevent core. Made calculations in terms of sector size of the disk to prevent the partition size mismatch.

* 4039525 (Tracking ID: 4012763)

SYMPTOM:
I/O may hang in a VVR configuration when the SRL overflows for one rlink while another rlink is in the AUTOSYNC mode.

DESCRIPTION:
In a VVR configuration, it may happen that the SRL overflows for one rlink (say R1) while another rlink (say R2) has an ongoing AUTOSYNC operation. In such a scenario, AUTOSYNC is aborted for R2, R2 gets detached, and DCM mode is activated on R1. However, a race condition occurs internally while handling the AUTOSYNC abort and the DCM activation tasks in parallel. Consequently, the DCM is not activated properly, the I/O that triggered the DCM activation gets queued incorrectly, and the I/O hangs.

RESOLUTION:
VVR is updated to fix the internal race issue that occurs when handling the AUTOSYNC abort and the DCM activation tasks at same time, thus avoiding the I/O hang.

* 4039526 (Tracking ID: 4034616)

SYMPTOM:
vol_seclog_limit_ioload tunable needs to be enabled on Linux only.

DESCRIPTION:
vol_seclog_limit_ioload tunable needs to be enabled on Linux only.

RESOLUTION:
The code changes are implemented to disable the tunable 'vol_seclog_limit_ioload' on non-linux platforms.

* 4039527 (Tracking ID: 4018086)

SYMPTOM:
vxiod with ID as 128 was stuck with below stack:

 #2 [] vx_svar_sleep_unlock at [vxfs]
 #3 [] vx_event_wait at [vxfs]
 #4 [] vx_async_waitmsg at [vxfs]
 #5 [] vx_msg_send at [vxfs]
 #6 [] vx_send_getemapmsg at [vxfs]
 #7 [] vx_cfs_getemap at [vxfs]
 #8 [] vx_get_freeexts_ioctl at [vxfs]
 #9 [] vxportalunlockedkioctl at [vxportal]
 #10 [] vxportalkioctl at [vxportal]
 #11 [] vxfs_free_region at [vxio]
 #12 [] vol_ru_start_replica at [vxio]
 #13 [] vol_ru_start at [vxio]
 #14 [] voliod_iohandle at [vxio]
 #15 [] voliod_loop at [vxio]

DESCRIPTION:
With SmartMove feature set to ON, the vxiod with ID as 128 starts the replication where RVG is in DCM mode. Thus, the vxiod awaits the filesystem's response if the given region is used by filesystem or not. Filesystem will trigger MDSHIP IO on logowner. Due to a bug in the code, MDSHIP IO always gets queued in vxiod with ID as 128. Hence a deadlock situation occurs.

RESOLUTION:
Code changes have been made to avoid handling the MDSHIP IO in vxiod whose ID is bigger than 127.

* 4045494 (Tracking ID: 4021939)

SYMPTOM:
The "vradmin syncvol" command fails and the following message is logged: "VxVM VVR vxrsync ERROR V-5-52-10206 no server host systems specified".

DESCRIPTION:
VVR sockets now bind without specifying IP addresses. This recent change causes issues when such interfaces are used to identify whether the associated remote host is same as the localhost. For example, in case of the "vradmin syncvol" command, VVR incorrectly assumes that the local host has been provided as the remote host, logs the error message and exits.

RESOLUTION:
Updated the vradmin utility to correctly identify the remote hosts that are passed to the "vradmin syncvol" command.

* 4047722 (Tracking ID: 4023390)

SYMPTOM:
Vxconfigd crashes as a disk contains invalid privoffset(160), which is smaller than minimum required offset(VTOC 265, GPT 208).

DESCRIPTION:
There may have disk label corruption or stale information residents on the disk header, which caused unexpected label written.

RESOLUTION:
Add a assert when updating CDS label to ensure the valid privoffset written to disk header.

* 4050892 (Tracking ID: 3991668)

SYMPTOM:
In a VVR configuration with secondary logging enabled, data inconsistency is reported after the "No IBC message arrived" error is encountered.

DESCRIPTION:
It might happen that the VVR secondary node handles updates with larger sequence IDs before the In-Band Control (IBC) update arrives. In this case, VVR drops the IBC update. Due to the updates with the larger sequence IDs than the one for the IBC update, data writes cannot be started, and they get queued. Data loss may occur after the VVR secondary receives an atomic commit and frees the queue. If this situation occurs, the "vradmin verifydata" command reports data inconsistency.

RESOLUTION:
VVR is modified to trigger updates as they are received in order to start data volume writes.

* 4051815 (Tracking ID: 4031597)

SYMPTOM:
vradmind generates a core dump in __strncpy_sse2_unaligned.

DESCRIPTION:
The following core dump is generated:
(gdb)bt
Thread 1 (Thread 0x7fcd140b2780 (LWP 90066)):
#0 0x00007fcd12b1d1a5 in __strncpy_sse2_unaligned () from /lib64/libc.so.6
#1 0x000000000059102e in IpmServer::accept (this=0xf21168, new_handlesp=0x0) at Ipm.C:3406
#2 0x0000000000589121 in IpmHandle::events (handlesp=0xf12088, new_eventspp=0x7ffc8e80a4e0, serversp=0xf120c8, new_handlespp=0x0, ms=100) at Ipm.C:613
#3 0x000000000058940b in IpmHandle::events (handlesp=0xfc8ab8, vlistsp=0xfc8938, ms=100) at Ipm.C:645
#4 0x000000000040ae2a in main (argc=1, argv=0x7ffc8e80e8e8) at srvmd.C:722

RESOLUTION:
vradmind is updated to properly handle getpeername(), which addresses this issue.

* 4051887 (Tracking ID: 3956607)

SYMPTOM:
When removing a VxVM disk using the vxdg-rmdisk operation, the following error occurs while requesting a disk reclaim:
VxVM vxdg ERROR V-5-1-0 Disk <device_name> is used by one or more subdisks which are pending to be reclaimed.
Use "vxdisk reclaim <device_name>" to reclaim space used by these subdisks, and retry "vxdg rmdisk" command.
Note: The reclamation operation is irreversible. However, a core dump occurs when vxdisk-reclaim is executed.

DESCRIPTION:
This issue occurs due to a memory allocation failure in the disk-reclaim code, which fails to be detected and causes an invalid address to be referenced. Consequently, a core dump occurs.

RESOLUTION:
The disk-reclaim code is updated to handle memory allocation failures properly.

* 4051889 (Tracking ID: 4019182)

SYMPTOM:
In case of a VxDMP configuration, an InfoScale server panics when applying a patch. The following stack trace is generated:
unix:panicsys+0x40()
unix:vpanic_common+0x78()
unix:panic+0x1c()
unix:mutex_enter() - frame recycled
vxdmp(unloaded text):0x108b987c(jmpl?)()
vxdmp(unloaded text):0x108ab380(jmpl?)(0)
genunix:callout_list_expire+0x5c()
genunix:callout_expire+0x34()
genunix:callout_execute+0x10()
genunix:taskq_thread+0x42c()
unix:thread_start+4()

DESCRIPTION:
Some VxDMP functions create callouts. The VxDMP module may already be unloaded when a callout expires, which may cause the server to panic. VxDMP should cancel any previous timeout function calls before it unloads itself.

RESOLUTION:
VxDMP is updated to cancel any previous timeout function calls before unloading itself.

* 4051896 (Tracking ID: 4010458)

SYMPTOM:
In a VVR environment, the rlink might inconsistently disconnect due to unexpected transactions, and the following message might get logged:
"VxVM VVR vxio V-5-0-114 Disconnecting rlink <rlink_name> to permit transaction to proceed"

DESCRIPTION:
In a VVR environment, a transaction is triggered when a change in the VxVM or the VVR objects needs to be persisted on disk. In some scenarios, a few unnecessary transactions get triggered in a loop, which was causes multiple rlink disconnects and the aforementioned message gets logged frequently. One such unexpected transaction occurs when the open/close command is issued for a volume as part of SmartIO caching. The vradmind daemon also issues some open/close commands on volumes as part of the I/O statistics collection, which triggers unnecessary transactions. Additionally, some unexpected transactions occur due to incorrect references to some temporary flags on the volumes.

RESOLUTION:
VVR is updated to first check whether SmartIO caching is configured on a system. If it is not configured, VVR disables SmartIO caching on the associated volumes. VVR is also updated to avoid the unexpected transactions that may occur due to incorrect references on certain temporary flags on the volumes.

* 4055653 (Tracking ID: 4049082)

SYMPTOM:
I/O read error is displayed when remote FSS node rebooting.

DESCRIPTION:
When rebooting remote FSS node, I/O read requests to a mirror volume that is scheduled on the remote disk from the FSS node should be redirected to the remaining plex. However, current vxvm does not handle this correctly. The retrying I/O requests could still be sent to the offline remote disk, which cause to final I/O read failure.

RESOLUTION:
Code changes have been done to schedule the retrying read request on the remaining plex.

* 4055660 (Tracking ID: 4046007)

SYMPTOM:
In FSS environment if the cluster name is changed then the private disk region gets corrupted.

DESCRIPTION:
Under some conditions, when vxconfigd tries to update the TOC (table of contents) blocks of disk private region, the allocation maps cannot be initialized in the memory. This could make allocation maps incorrect and lead to corruption of the private region on the disk.

RESOLUTION:
Code changes have been done to avoid corruption of private disk region.

* 4055668 (Tracking ID: 4045871)

SYMPTOM:
vxconfigd crashed at ddl_get_disk_given_path with following stacks:
ddl_get_disk_given_path
ddl_reconfigure_all
ddl_find_devices_in_system
find_devices_in_system
mode_set
setup_mode
startup
main
_start

DESCRIPTION:
Under some situations, duplicate paths can be added in one dmpnode in vxconfigd. If the duplicate paths are removed then the empty path entry can be generated for that dmpnode. Thus, later when vxconfigd accesses the empty path entry, it crashes due to NULL pointer reference.

RESOLUTION:
Code changes have been done to avoid the duplicate paths that are to be added.

* 4055697 (Tracking ID: 4047793)

SYMPTOM:
When replicated disks are in SPLIT mode, importing its diskgroup failed with "Device is a hardware mirror".

DESCRIPTION:
When replicated disks are in SPLIT mode, which are r/w, importing its diskgroup failed with "Device is a hardware mirror". Third party doesn't expose disk attribute to show when it's in SPLIT mode. Now DMP refers to its REPLICATED status to judge if diskgroup import is allowed or not. `-o usereplicatedev=on/off` is enhanced to archive it.

RESOLUTION:
The code is enhanced to allow diskgroup import when replicated disks are in SPLIT mode.

* 4055772 (Tracking ID: 4043337)

SYMPTOM:
rp_rv.log file uses space for logging.

DESCRIPTION:
rp_rv log files needs to be removed and logger file should have 16 mb rotational log files.

RESOLUTION:
The code changes are implemented to disabel logging for rp_rv.log files

* 4055895 (Tracking ID: 4038865)

SYMPTOM:
In IRQ stack, the system panics at VxDMP module with the following calltrace:
native_queued_spin_lock_slowpath
queued_spin_lock_slowpath
_raw_spin_lock_irqsave7
dmp_get_shared_lock
gendmpiodone
dmpiodone
bio_endio
blk_update_request
scsi_end_request
scsi_io_completion
scsi_finish_command
scsi_softirq_done
blk_done_softirq
__do_softirq
call_softirq
do_softirq
irq_exit
do_IRQ
 <IRQ stack>

DESCRIPTION:
A deadlock issue occurred between inode_hash_lock and DMP shared lock when one process was holding inode_hash_lock, but acquired the DMP shared lock in IRQ context and the other processes holding the DMP shared lock acquired the inode_hash_lock.

RESOLUTION:
To avoid the deadlock issue, the code changes are done.

* 4055899 (Tracking ID: 3993242)

SYMPTOM:
vxsnap prepare on vset might throw error : "VxVM vxsnap ERROR V-5-1-19171 Cannot perform prepare operation on cloud 
volume"

DESCRIPTION:
There were  some wrong volume-records entries being fetched for VSET and due to which required validations were failing and triggering the issue .

RESOLUTION:
Code changes have been done to resolve the issue .

* 4055905 (Tracking ID: 4052191)

SYMPTOM:
Any scripts or command files in the / directory may run unexpectedly when the system starts and vxvm volumes will not be available until those scripts or commands are complete.

DESCRIPTION:
If this issue occurs, /var/svc/log/system-vxvm-vxvm-configure:default.log indicates that a script or a command located in the / directory has been executed.
For example,
ABC Script ran!!
/lib/svc/method/vxvm-configure[241] abc.sh not found
/lib/svc/method/vxvm-configure[242] abc.sh not found
/lib/svc/method/vxvm-configure[243] abc.sh not found
/lib/svc/method/vxvm-configure[244] app/ cannot execute
In this example, abc.sh is located in the / directory and just echoes "ABC script ran !!". vxvm-configure launched abc.sh.

RESOLUTION:
The incorrect comments format in the SunOS_5.11.vxvm-configure.sh script is corrected.

* 4055925 (Tracking ID: 4031064)

SYMPTOM:
During master switch with replication in progress, cluster wide hang is seen on VVR secondary.

DESCRIPTION:
With application running on primary, and replication setup between VVR primary & secondary, when master switch operation is attempted on secondary, it gets hung permanently.

RESOLUTION:
Appropriate code changes are done to handle scenario of master switch operation and replication data on secondary.

* 4055938 (Tracking ID: 3999073)

SYMPTOM:
Data corruption occurred when the fast mirror resync (FMR) was enabled and the failed plex of striped-mirror layout was attached.

DESCRIPTION:
To determine and recover the regions of volumes using contents of detach, a plex attach operation with FMR tracking has been enabled.

For the given volume region, the DCO region size being higher than the stripe-unit of volume, the code logic in plex attached code path was incorrectly skipping the bits in detach maps. Thus, some of the regions (offset-len) of volume did not sync with the attached plex leading to inconsistent mirror contents.

RESOLUTION:
To resolve the data corruption issue, the code has been modified to consider all the bits for given region (offset-len) in plex attached code.

* 4056107 (Tracking ID: 4036181)

SYMPTOM:
IO error has been reported when RVG is not in enabled state after boot-up.

DESCRIPTION:
When RVG is not enabled/active, the volumes under a RVG will report an IO error.
Messages logged:
systemd[1]: Starting File System Check on /dev/vx/dsk/vvrdg/vvrdata1...
systemd-fsck[4977]: UX:vxfs fsck.vxfs: ERROR: V-3-20113: Cannot open : No such device or address  
systemd-fsck[4977]: fsck failed with error code 31.
systemd-fsck: UX:vxfs fsck.vxfs: ERROR: V-3-20005: read of super-block on /dev/vx/dsk/vvrdg/vvrdata1 failed: Input/output error

RESOLUTION:
Issue got fixed by enabling the RVG using vxrvg command if the RVG is in disabled/recover state.

* 4056124 (Tracking ID: 4008664)

SYMPTOM:
System panic occurs with the following stack:

void genunix:psignal+4()
void vxio:vol_logger_signal_gen+0x40()
int vxio:vollog_logentry+0x84()
void vxio:vollog_logger+0xcc()
int vxio:voldco_update_rbufq_chunk+0x200()
int vxio:voldco_chunk_updatesio_start+0x364()
void vxio:voliod_iohandle+0x30()
void vxio:voliod_loop+0x26c((void *)0)
unix:thread_start+4()

DESCRIPTION:
Vxio keeps vxloggerd proc_t that is used to send a signal to vxloggerd. In case vxloggerd has been ended for some reason, the signal may be sent to an unexpected process, which may cause panic.

RESOLUTION:
Code changes have been made to correct the problem.

* 4056146 (Tracking ID: 3983832)

SYMPTOM:
When the disk groups are deleted, multiple VxVM commands get hang in CVR secondary site.

DESCRIPTION:
VxVM command hangs when a deadlock was encountered during kmsg broadcast while deleting disk group and IBC unfreeze operation.

RESOLUTION:
Changes are done in VxVM code check either by transactions or avoiding deadlock.

* 4056918 (Tracking ID: 4056917)

SYMPTOM:
In Flexible Storage Sharing (FSS) environments, disk group import operation with few disks missing leads to data corruption.

DESCRIPTION:
In FSS environments, import of disk group with missing disks is not allowed. If disk with highest updated configuration information is not present during import, the import operation fired was leading incorrectly incrementing the config TID on remaining disks before failing the operation. When missing disk(s) with latest configuration came back, import was successful. But because of earlier failed transaction, import operation incorrectly choose wrong configuration to import the diskgroup leading to data corruption.

RESOLUTION:
Code logic in disk group import operation is modified to ensure failed/missing disks check happens early before attempting perform any on-disk update as part of import.

* 4057208 (Tracking ID: 4053864)

SYMPTOM:
On Sol 11.4, "dump:config" and "swap:default" methods failed to start with the errors like the following:
svc:/system/dump:config: Method "/lib/svc/method/svc-dump-config" failed with exit status 96.
svc:/system/swap:default: Method "/usr/sbin/swapadd" failed with exit status 2

DESCRIPTION:
Since 11.4 Solaris made some changes to the dump/swap method by splitting one method to multiples, by which some of the methods may get started before underlying zpool/dmp devices are ready. Hence dump/swap methods may fail.

RESOLUTION:
New method dependencies are introduced to resolve the issue.

Patch ID: VRTSvxvm-7.4.1.2600

* 3968739 (Tracking ID: 3968334)

SYMPTOM:
If the OS of the system is upgraded from 11.3 to 11.4 then on reboot newer library were not copied pertaining to Solaris 11.4.

DESCRIPTION:
In Solaris 11.4 the concept of dual VRTS_vxvm_link.so library support for Solaris was included. In Solaris 11 the work of postinstall script is done by vxvm-configure script. The script runs only once and then it skips because of the .vxvm-configured file being present. If the OS of the system is upgraded from 11.3 to 11.4 then on reboot newer library should be copied pertaining to Solaris 11.4. But since the check for the file is there, copying of the library is skipped on boot.

RESOLUTION:
Changes have been done to verify the cksum of the library and then decide where new module replacing is required or not even if the .vxvm-configured file is present.

* 3984165 (Tracking ID: 3982817)

SYMPTOM:
Appropriate modules are not loaded on the system during fresh installation of InfoScale on Solaris 11.4 system

DESCRIPTION:
During fresh installation of InfoScale Enterprise software on Solaris 11.4 system both the base release as well as the patch are installed with one command. The base release does not have support for Solaris 11.4 and hence as part of installing base release an entry for older modules is registered with Operating system. Because of this older entry the load of newer modules to support Solaris 11.4 which are part of the patch cannot succeed. This leads to error during installation which can be only resolved post reboot.

RESOLUTION:
Changes have been done to verify if the modules present in the current patch are newer and accordingly remove the stale entry of older modules from Operating System.

* 4005540 (Tracking ID: 3970627)

SYMPTOM:
vxstat command shows incorrect data for IO Operations.

DESCRIPTION:
vxstat command shows accumulated data for IO Operations for underlying disks. The IO operations for disk 1 would be added to disk 2 and then displayed. Similar thing would happen for disk2/disk3 and so on. The issue occurs because the memory allocated to store these values are not reset to 0 for different disks leading to garbage/incorrect values being displayed as part of the command output.

RESOLUTION:
Appropriate changes have been incorporated to reset the memory to 0 while calculating stats for each of the disks.

* 4006949 (Tracking ID: 4006539)

SYMPTOM:
zpool corruption occurs when DMP Native Support is enabled on two servers at the same time.

DESCRIPTION:
When DMP Native Support is enabled then all the zpools present on the system are migrated to DMP devices. During migration even exported zpools are imported on top of DMP devices. If the same operation is carried out on 2 servers having shared storage then zpools would be imported on top of DMP devices on both the servers approximately at the same time which leads to zpool corruption.

RESOLUTION:
Changes have been done to not import exported zpools on top of DMP devices and let the customer decide which zpools to import on which server.

* 4008748 (Tracking ID: 3989185)

SYMPTOM:
In a Veritas Volume Manager(VVR) environment vxrecover command can hang.

DESCRIPTION:
When vxrecover is triggered after storage failure it is possible that the vxrecover operation may hang.
This is because vxrecover does the RVG recovery. As part of this recovery dummy updates are written on SRL.
Due to a bug in the code these updated were written incorrectly on the SRL which led the flush operation from SRL to data volume hang.

RESOLUTION:
Code changes are done appropriately so that the dummy updates are written  correctly to the SRL.

* 4010517 (Tracking ID: 3998475)

SYMPTOM:
Data corruption is observed and service groups went into partial state.

DESCRIPTION:
In VxVM, fsck log replay initiated read of 64 blocks, that was getting split across 2 stripes of the stripe-mirror volume. 
So, we had 2 read I/Os of 48 blocks (first split I/O) and 16 blocks (second split I/O).
Since the volume was in RWBK mode, this read I/O was stabilized. Upon completion of the read I/O at subvolume level, this I/O was unstabilized and the contents 
of the stable I/O (stablekio) were copied to the original I/O (origkio). It was observed that the data was always correct till the subvolume level but at the 
top level plex and volume level, it was incorrect (printed checksum in vxtrace output for this).

The reason for this was during unstabilization, we do volkio_to_kio_copy() which copies the contents from stable kio to orig kio (since it is a read).
As the orig kio was an unmapped PHYS I/O, in Solaris 11.4, the contents will be copied out using bp_copyout() from volkiomem_kunmap(). The volkiomem_seek() and 
volkiomem_next_segment() allocates pagesize (8K) kernel buffer (zero'ed out) where the contents will be copied to.
When the first split I/O completes unstabilization before the second split I/O, this issue was not seen. However, if the second split 
I/O completed before the first splt I/O then this issue was seen. 

Here, in the last iteration of the volkio_to_kio_copy(), the data copied was less than the allocated region size. We allocate 8K region size whereas the data 
copied from stablekio was less than 8K. Later, during kunmap(), we do a bp_copyout() of alloocated size i.e. 8K. This caused copyout of extra regions that were 
zero'ed out. Hence the data corruption.

RESOLUTION:
Now we do a bp_copyout() of the right length i.e. of the copied size instead of the allocated region size.

* 4010520 (Tracking ID: 4003805)

SYMPTOM:
Panic encountered when Oracle UFS directly uses mirrored volumes with DCOs on IS 7.4.1/Sol11.4. System panic with below stack:
unix:ktl0+7c ()
vxio:voliomem_range_iter+c ()
vxio:volkio_to_iomem_copy+114 ()
vxio:volsio_stabilize+f0 ()
vxio:vol_mv_write_start+9cc ()
Or
bcopy_more+0x1284()
volkio_to_iomem_copy+0x178()
volsio_stabilize+0xf0()
vol_mv_write_start+0xa98()
volkcontext_process+0x124()
volkiostart+0x1144()
vxiostrategy+0xd4()
spec_cb_strategy+0x7c()

DESCRIPTION:
When B_MVECTOR is set on a buffer, that means this is a unmapped buffer. Volume Manager missed this flag and directly access this buffer, hence the panic.

RESOLUTION:
Code changes have been done to use bp_mapin() to properly set b_addr if B_MVECTOR is set.

Patch ID: VRTSllt-7.4.1.1100

* 4050664 (Tracking ID: 4046199)

SYMPTOM:
LLT configurations over UDP accept only ethernet interface names as link tag names.

DESCRIPTION:
The tag field in the link definition accepts only the ethernet interface name as a value.

RESOLUTION:
The LLT module is updated to accept any string a as link tag name.

* 4051040 (Tracking ID: 3989372)

SYMPTOM:
When the CPU load and memory consumption is high in a VMware environment, some nodes in an InfoScale cluster may get fenced out.

DESCRIPTION:
Occasionally, in a VMware environment, the operating system may not schedule LLT contexts on time. Consequently, heartbeats from some of the cluster nodes may be lost, and those nodes may get fenced out. This situation typically occurs when the CPU load or the memory usage is high or when the VMDK snapshot or vMotion operations are in progress.

RESOLUTION:
This fix attempts to make clusters more resilient to transient issues by heartbeating using threads bound to every vCPU.

* 4054272 (Tracking ID: 4045607)

SYMPTOM:
LLT over UDP support for transmission and reception of data over 1500 MTU networks.

DESCRIPTION:
The UDP multiport feature in LLT performs poorly in case of 1500 MTU-based networks. Data packets larger than 1500 bytes cannnot be transmitted over 1500 MTU-based networks, so the IP layer fragments them appropriately for transmission. The loss of a single fragment from the set leads to a total packet (I/O) loss. LLT then retransmits the same packet repeatedly until the transmission is successful. Eventually, you may encounter issues with the Flexible Storage Sharing (FSS) feature. For example, the vxprint process or the disk group creation process may stop responding, or the I/O-shipping performance may degrade severely.

RESOLUTION:
The UDP multiport feature of LLT is updated to fragment the packets such that they can be accommodated in the 1500-byte network frame. The fragments are rearranged on the receiving node at the LLT layer. Thus, LLT can track every fragment to the destination, and in case of transmission failures, retransmit the lost fragments based on the current RTT time.

* 4054697 (Tracking ID: 3985775)

SYMPTOM:
Sometimes, the system log may get flooded with LLT heartbeat loss messages that do not necessarily indicate any actual issues with LLT.

DESCRIPTION:
LLT heartbeat loss messages can appear in the system log either due to actual heartbeat drops in the network or due to heartbeat packets arriving out of order. In either case, these messages are only informative and do not indicate any issue in the LLT functionality. Sometimes, the system log may get flooded with these messages, which are not useful.

RESOLUTION:
The LLT module is updated to lower the frequency of printing LLT heartbeat loss messages. This is achieved by increasing the number of missed sequential HB packets required to print this informative message.

Patch ID: VRTSgab-7.4.1.1100

* 4054264 (Tracking ID: 4046413)

SYMPTOM:
After a node is added to or removed from a cluster, the GAB node count or the fencing quorum is not updated.

DESCRIPTION:
The gabconfig -m <node_count> command returns an error even if the correct node count is provided.

RESOLUTION:
To address this issue, a parsing issue with the GAB module is fixed.

* 4054265 (Tracking ID: 4046418)

SYMPTOM:
The GAB module starts up even if LLT is not configured.

DESCRIPTION:
Since the GAB service depends on the LLT service, if LLT fails to start or if it is not configured, GAB should not start.

RESOLUTION:
The GAB module is updated to start only if LLT is configured.

Patch ID: VRTSamf-7.4.1.1100

* 4054323 (Tracking ID: 4001565)

SYMPTOM:
On Solaris 11.4, IMF fails to provide notifications when Oracle processes stop.

DESCRIPTION:
On Solaris 11.4, when Oracle processes stop, IMF provides notification to Oracle agent, but the monitor is not scheduled. As as result, agent fails intelligent monitoring.

RESOLUTION:
Oracle agent now provides notifications when Oracle processes stop.

Patch ID: VRTSvxfen-7.4.1.1200

* 4016876 (Tracking ID: 4000745)

SYMPTOM:
The VxFEN process fails to start due to late discovery of the VxFEN disk group.

DESCRIPTION:
When I/O fencing starts, the VxFEN startup script creates this /etc/vxfentab file on each node. During disk-based fencing, the VxVM module may take longer time to discover the VxFEN disk group. Because of this delay, the 'generate disk list' opreration times out. Therefore, the VxFEN process fails to start and reports the following error: 'ERROR: VxFEN cannot generate vxfentab because vxfendg does not exist'

RESOLUTION:
A new tunable, getdisks_timeout, is introduced to specify the timeout value for the VxFEN disk group discovery. The maximum and the default value for this tunable is 600 seconds. You can set the value of this tunable by adding an getdisks_timeout=<time_in_sec> entry in the /etc/vxfenmode file.

Patch ID: VRTSvxfen-7.4.1.1100

* 3986554 (Tracking ID: 3986553)

SYMPTOM:
After the phase 1 of a rolling upgrade completes, a CoordPoint resource goes into the FAULTED state.

DESCRIPTION:
This issue occurs when the CoordPoint agent is upgraded to 7.4.1 from any earlier version using a rolling upgrade. A field was added to the VXFEN driver structure due to which the client, VXFEN_IOC_GET_COORD IOCTL, fails.

RESOLUTION:
This hotfix addresses the issue by providing a global field to serve the purpose instead of adding a field to the VXFEN driver structure.

Patch ID: VRTSvcs-7.4.1.1200

* 4054266 (Tracking ID: 4040705)

SYMPTOM:
When a command exceeds 4096 characters, hacli hangs indefinitely.

DESCRIPTION:
Instead of returning the appropriate error message, hacli waits indefinitely for a reply from the VCS engine.

RESOLUTION:
Increased the limit of the hacli '-cmd' option to 7680 characters. Validations for the various hacli options are also now handled better. Thus, when the value of the '-cmd' option exceeds the new limit, hacli no longer hangs, but instead returns the appropriate proper error message.

* 4054267 (Tracking ID: 4040656)

SYMPTOM:
When the ENOMEM error occurs, HAD does not shut down gracefully.

DESCRIPTION:
When HAD encounters the ENOMEM error, it reattempts the operation a few times until it reaches a predefined maximum limit, and then it exits. The hashadow daemon restarts HAD with the '-restart' option. The failover service group in the cluster is not started automatically, because it appears that one of the cluster nodes is in the 'restarting' mode.

RESOLUTION:
HAD is enhanced to exit gracefully when it encounters the ENOMEM error, and the hashadow daemon is updated to restart HAD without the '-restart' option. This enhancement ensures that in such a scenario, the autostart of a failover service group is triggered as expected.

* 4054271 (Tracking ID: 4043700)

SYMPTOM:
In case of failover, parallel, or hybrid service groups, multiple PreOnline triggers can be executed on the same node or on different nodes in a cluster while an online operation is in already progress.

DESCRIPTION:
This issue occurs because the validation of online operations did not take the ongoing execution of PreOnline triggers into consideration. Thus, subsequent online operations are accepted while a PreOnline trigger is already being executed. Consequently, multiple PreOnline trigger instances are executed.

RESOLUTION:
A check for PreOnline triggers is added to the validation of ongoing online operations, and subsequent calls for online operations are rejected. Thus, the PreOnline trigger for failover groups is executed only once.

Patch ID: VRTSvcs-7.4.1.1100

* 3982912 (Tracking ID: 3981992)

SYMPTOM:
A potentially critical security vulnerability in VCS needs to be addressed.

DESCRIPTION:
A potentially critical security vulnerability in VCS needs to be addressed.

RESOLUTION:
This hotfix addresses the security vulnerability. For details, refer to the security advisory at: https://www.veritas.com/content/support/en_US/security/VTS19-003.html

Patch ID: VRTSvcsea-7.4.1.1200

* 4054325 (Tracking ID: 4043289)

SYMPTOM:
In an Oracle ASM 19c environment on Solaris, the ASMInst agent fails to come online or to detect the state of the related resources.

DESCRIPTION:
This issue occurs due to incorrect permissions on certain Oracle files on Solaris.

RESOLUTION:
The ASMInst agent is updated to handle the change in permissions that causes this issue.

* 3982248 (Tracking ID: 3989510)

SYMPTOM:
The VCS agent for Oracle does not support Oracle 19c databases.

DESCRIPTION:
In case of non-CDB or CDB-only databases, the VCS agent for Oracle does not recognize that an Oracle 19c resource is intentionally offline after a graceful shutdown. This functionality is never supported for PDB-type databases.

RESOLUTION:
The agent is updated to recognize the graceful shutdown of an Oracle 19c resource as intentional offline in case of non-CDB or CDB-only databases. For details, refer to the article at: https://www.veritas.com/support/en_US/article.100046803.

Patch ID: VRTScavf-7.4.1.3400

* 4056567 (Tracking ID: 4054462)

SYMPTOM:
In a hardware replication environment, a shared disk group resource may fail to be imported when the HARDWARE_MIRROR flag is set.

DESCRIPTION:
After the VCS hardware replication agent resource fails over control to the secondary site, the CVMVolDg agent does not rescan all the required device paths in case of a multi-pathing configuration. The vxdg import operation fails, because the hardware device characteristics for all the paths are not refreshed.

RESOLUTION:
This hotfix addresses the issue by providing two new resource-level attributes for the CVMVolDg agent.
- The ScanDisks attribute specifies whether to perform a selective for all the disk paths that are associated with a VxVM disk group. When ScanDisks is set to 1, the agent performs a selective devices scan. Before attempting to import a hardware clone or a hardware replicated device, the VxVM and the DMP attributes of a disk are refreshed. ScanDisks is set to 0 by default, which indicates that a selective device scan is not performed. However, even when ScanDisks is set to 0, if the disk group fails during the first import attempt, the agent checks the error string. If the string contains the text HARDWARE_MIRROR, the agent performs a selective device scan to increase the chances of a successful import.
- The DGOptions attribute specifies options to be used with the vxdg import command that is executed by the agent to bring the CVMVolDg resource online.
Sample resource configuration for hardware replicated shared disk groups:
CVMVolDg tc_dg (
    CVMDiskGroup = datadg
    CVMVolume = { vol01 }
    CVMActivation = sw
    CVMDeportOnOffline = 1
    ClearClone = 1
    ScanDisks = 1
    DGOptions = "-t -o usereplicatedev=on"
    )

Patch ID: VRTSvlic-4.01.741.300

* 4049416 (Tracking ID: 4049416)

SYMPTOM:
Frequent Security vulnerabilities reported in JRE.

DESCRIPTION:
There are many vulnerabilities reported in JRE every quarter. To overcome this vulnerabilities issue migrate Licensing Collector service from Java to Python.
All other behavior of Licensing Collector service will remain the same.

RESOLUTION:
Migrated Licensing Collector service from Java to Python.

Patch ID: VRTSpython-3.6.6.10

* 4056779 (Tracking ID: 4049771)

SYMPTOM:
The VRTSpython package needs to be made available on AIX and Solaris to support the InfoScale licensing component.

DESCRIPTION:
Certain Python modules are required for the InfoScale Core Plus licensing component to function. To support this component, the VRTSpython package needs to be made available for the AIX and the Solaris platforms.

RESOLUTION:
This patch deploys the VRTSpython package on AIX and Solaris.

Patch ID: VRTSvxfs-7.4.1.3400

* 4026389 (Tracking ID: 4026388)

SYMPTOM:
fscache and sfcache command exited with the following error while performing unpin file
UX:vxfs fscache: ERROR: V-3-28059:  -o load is supported only for pin option

DESCRIPTION:
fscache and sfcache  commands report error while unpinning file from VxFS cache device.

RESOLUTION:
Code changes introduced to fix the error.

* 4050229 (Tracking ID: 4018995)

SYMPTOM:
System gets panic in AIX when doing read ahead of size greater than 4 GB.

DESCRIPTION:
There is a data type mismatch (64bit - 32bit) in VxFS read ahead code path which leads to page list size being truncated and causing the system to panic with the following stack:
vx_getpage_cleanup
vx_do_getpage
vx_mm_getpage
vx_do_read_ahead
vx_cache_read_noinline
vx_read_common_noinline
vx_read1
vx_read
vx_rdwr_attr

RESOLUTION:
The data type mismatch has been fixed in code to handle such scenarios.

* 4053149 (Tracking ID: 4043084)

SYMPTOM:
panic in vx_cbdnlc_lookup

DESCRIPTION:
Panic observed in the following stack trace:
vx_cbdnlc_lookup+000140 ()
vx_int_lookup+0002C0 ()
vx_do_lookup2+000328 ()
vx_do_lookup+0000E0 ()
vx_lookup+0000A0 ()
vnop_lookup+0001D4 (??, ??, ??, ??, ??, ??)
getFullPath+00022C (??, ??, ??, ??)
getPathComponents+0003E8 (??, ??, ??, ??, ??, ??, ??)
svcNameCheck+0002EC (??, ??, ??, ??, ??, ??, ??)
kopen+000180 (??, ??, ??)
syscall+00024C ()

RESOLUTION:
Code changes to handle memory pressure while changing FC connectivity

* 4054243 (Tracking ID: 4014274)

SYMPTOM:
Gsed cmd might report a bad address error when VxFS receives 
ACE(access control entry) masking flag.

DESCRIPTION:
While performing Gsed cmd on VxFS filesystem, if VxFS receives ACE_GETACLCNT 
and ACE_GETACL masking flags; VxFS might report bad address error as VxFS 
does not support ACE(access control entry) flags.

RESOLUTION:
Added a code to handle ACE flags

* 4054244 (Tracking ID: 4052449)

SYMPTOM:
Cluster goes in an 'unresponsive' mode while invalidating pages due to duplicate page entries in iowr structure.

DESCRIPTION:
While finding pages for invalidation of inodes, VxFS traverses radix tree by taking RCU lock and fills the IO structure with dirty/writeback pages that need to be invalidated in an array. This lock is efficient for read but does not protect the parallel creation/deletion of node. Hence, when VxFS finds page, consistency for the page in checked through radix_tree_exception()/radix_tree_deref_retry(). And if it fails, VxFS restarts the page finding from start offset. But VxFs does not reset the array index, leading to incorrect filling of IO structure's array which was causing  duplicate entries of pages. While trying to destroy these pages, VxFS takes page lock on each page. Because of duplicate entries, VxFS tries to take page lock couple of times on same page, leading to self-deadlock.

RESOLUTION:
Code is modified to reset the array index correctly in case of failure to find pages.

* 4054387 (Tracking ID: 4054386)

SYMPTOM:
VxFS systemd service may show active status despite the module not being loaded.

DESCRIPTION:
If systemd service fails to load vxfs module, the service still shows status as active instead of failed.

RESOLUTION:
The script is modified to show the correct status in case of such failures.

* 4054412 (Tracking ID: 4042254)

SYMPTOM:
vxupgrade sets fullfsck flag in the filesystem if it is unable to upgrade the disk layout version because of ENOSPC.

DESCRIPTION:
If the filesystem is 100 % full and  its disk layout version is upgraded by using vxupgrade, then this utility starts the upgrade and later it fails with ENOSPC and ends up setting fullfsck flag in the filesystem.

RESOLUTION:
Code changes introduced which first calculate the required space to perform the disk layout upgrade. If the required space is not available, it fails the upgrade gracefully without setting fullfsck flag.

* 4054416 (Tracking ID: 4005620)

SYMPTOM:
Inode count maintained in the inode allocation unit (IAU) can be negative when an IAU is marked bad. An error such as the following is logged.

V-2-4: vx_mapbad - vx_inoauchk - /fs1 file system free inode bitmap in au 264 marked bad

Due to the negative inode count, errors like the following might be observed and processes might be stuck at inode allocation with a stack trace as shown.

V-2-14: vx_iget - inode table overflow

	vx_inoauchk 
	vx_inofindau 
	vx_findino 
	vx_ialloc 
	vx_dirmakeinode 
	vx_dircreate 
	vx_dircreate_tran 
	vx_pd_create 
	vx_create1_pd 
	vx_do_create 
	vx_create1 
	vx_create0 
	vx_create 
	vn_open 
	open

DESCRIPTION:
The inode count can be negative if somehow VxFS tries to allocate an inode from an IAU where the counter for regular file and directory inodes is zero. In such a situation, the inode allocation fails and the IAU map is marked bad. But the code tries to further reduce the already-zero counters, resulting in negative counts that can cause subsequent unresponsive situation.

RESOLUTION:
Code is modified to not reduce inode counters in vx_mapbad code path if the result is negative. A diagnostic message like the following flashes.
"vxfs: Error: Incorrect values of ias->ifree and Aus rifree detected."

* 4054724 (Tracking ID: 4018697)

SYMPTOM:
After installing InfoScale 7.4.2, when the system is started, it fails to start with the following message:
an inconsistency in the boot archive was detected the boot archive will be updated, then the system will reboot

DESCRIPTION:
Due to a defect in the vxfs-modload service, vxfs modules get copied to the system on each reboot. As a result, the system goes into an inconsistent state and gets stuck in a reboot loop.

RESOLUTION:
The vxfs-modload script is modified to address this defect.

* 4054725 (Tracking ID: 4051108)

SYMPTOM:
While storing multiple attributes for a file in an immediate area of inode, system might be unresponsive due to a wrong loop increment statement.

DESCRIPTION:
While storing attribute for a file in an immediate area of inode, loop is used to store multiple attributes one-by-one. Presence of wrong loop increment statement might cause loop to execute indefinitely. The system might be unresponsive as a result.

RESOLUTION:
Code is corrected to increment loop variable properly after loop iterations.

* 4054726 (Tracking ID: 4051026)

SYMPTOM:
If file system is created with inode size 512, the file system might report inconsistencies with the bitmap after running fsck .

DESCRIPTION:
With inode size 512, while running fsck some of the inodes are getting marked as allocated even though they are free . Bitmaps are actually correct on-disk but fsck reports it wrong.

RESOLUTION:
Fixed FSCK binary to mark indoes allocated/free correctly.

* 4055858 (Tracking ID: 4042925)

SYMPTOM:
Intermittent Performance issue on commands like df and ls.

DESCRIPTION:
Commands like "df" "ls" issue stat system call on node to calculate the statistics of the file system. In a CFS, when stat system call is issued, it compiles statistics from all nodes. When multiple df or ls are fired within specified time limit, vxfs is optimized. vxfs returns the cached statistics, instead of recalculating statistics from all nodes. If multiple such commands are fired in succession and one of the old caller of stat system call takes time, this optimization fails and VxFS recompiles statistics from all nodes. This can lead to bad performance of stat system call, leading to unresponsive situations for df, ls commands.

RESOLUTION:
Code is modified to protect last modified time of stat system call with a sleep lock.

Patch ID: VRTSodm-7.4.1.3400

* 4054481 (Tracking ID: 4021566)

SYMPTOM:
VxODM service fails to start due to a race between odm-run-once and vxodm service.

DESCRIPTION:
odm-run-once and vxodm start through SMF service of Solaris.
As both are independent, these can be started in any 
order. If vxodm service gets executed before odm-run-once script, 
vxodm service faults and goes in a maintenance mode.

RESOLUTION:
Code changes introduced to merge the information of odm-run-once script 
into the odm script itself.



INSTALLING THE PATCH
--------------------
Run the Installer script to automatically install the patch:
-----------------------------------------------------------
Please be noted that the installation of this P-Patch will cause downtime.

To install the patch perform the following steps on at least one node in the cluster:
1. Copy the patch infoscale-sol11_sparc-Patch-7.4.1.2300.tar.gz to /tmp
2. Untar infoscale-sol11_sparc-Patch-7.4.1.2300.tar.gz to /tmp/hf
    # mkdir /tmp/hf
    # cd /tmp/hf
    # gunzip /tmp/infoscale-sol11_sparc-Patch-7.4.1.2300.tar.gz
    # tar xf /tmp/infoscale-sol11_sparc-Patch-7.4.1.2300.tar
3. Install the hotfix(Please be noted that the installation of this P-Patch will cause downtime.)
    # pwd /tmp/hf
    # ./installVRTSinfoscale741P2300 [<host1> <host2>...]

You can also install this patch together with 7.4.1 base release using Install Bundles
1. Download this patch and extract it to a directory
2. Change to the Veritas InfoScale 7.4.1 directory and invoke the installer script
   with -patch_path option where -patch_path should point to the patch directory
    # ./installer -patch_path [<path to this patch>] [<host1> <host2>...]

Install the patch manually:
--------------------------
To apply the patch manually, perform the steps listed below on each node.
Ensure that the "/opt/VRTS/bin" directory is included in your PATH environment variable.
1. Stop VCS:
    # haconf -dump -makero
    # hastop -local -force
2. Apply the patch by issuing the following commands:
   a. Set the publisher
        # pkg set-publisher -p <patch_file_pathname>     Veritas
      e.g:
        # pkg set-publisher -p /patches/VRTSvcsag.p5p Veritas
   b. Install the package
        # pkg install --accept --no-backup-be VRTSvcsag
3. Verify that the new package is installed.  The output of the following
    command should display the version for VRTSvcsag package as 7.4.1.1200:
   # pkg info VRTSvcsag
4. Unset the publisher:
   # pkg unset-publisher Veritas
5. Start VCS:
   # hastart


REMOVING THE PATCH
------------------
Note:  Uninstalling this patch will remove the entire VRTSvcsag package. If you need
 an earlier version of the package, re-install it from original source media (ref. step 3 below).
Run the following steps on all the nodes in the VCS cluster:
1. Stop VCS:
    # haconf -dump -makero
    # hastop -local -force
2. Uninstall the VRTSvcsag package:
   a. If you have local zones on the system, uninstall the VRTSvcsag package and its dependent packages from all
    local zones in which it is present (repeat with <zonename>    set to each local zone in which VRTSvcsag is installed):
        # zlogin <zonename>     pkg uninstall VRTSvcsag VRTSvcswiz
   b. Once the package is uninstalled from all local zones, uninstall the VRTSvcsag package and its dependent packages from the global zone:
        # pkg uninstall VRTSvcsag VRTSvcswiz
3. (optional) Install the previous version of the VRTSvcsag package and its dependent packages from original
    source media to revert your system to pre-patch conditions.
4. Start VCS:
   # hastart


KNOWN ISSUES
------------
* Tracking ID: 4063539

SYMPTOM: After rolling upgrade from InfoScale 7.3.1 latest patch 2500 to InfoScale 7.4.1 Update6 on Solaris 11 in zones, vxconfigd failed to get started.

WORKAROUND: There is no workaround as of now . Will be targeted in upcoming 741 release.

* Tracking ID: 4063807

SYMPTOM: GAB processes fail to stop during a full upgrade from 6.2.1 to 7.4.1U6 (4063805)

WORKAROUND: To remove the stale state of the older version of the loaded GAB driver, properly restart your systems when the installer prompts you to do after 
the completion of the upgrade. The services get started automatically after the systems are restarted.

* Tracking ID: 4028441

SYMPTOM: While running the fsmigadm analyse on the source volume mounted by ufs which is greater than the target file system is passing, which should ideally fail.

WORKAROUND: No



SPECIAL INSTRUCTIONS
--------------------
Following vulnerabilities has been resolved in 741U6(VRTSpython 3.6.6.10)
CVE-2017-18342
CVE-2020-14343
CVE-2020-1747
Resolution: Upgraded pyyaml to 5.4.1 version
CVE-2019-10160
CVE-2019-9636
CVE-2020-27619
Resolution: Patched the source code of the python itself referenced in corresponding BDSA to resolve the vulnerabilities.

------------------------------------------------------------------------------------------------------------------------------------------------
Issue: After Full Upgrade With Zones On Solaris 11.4 The Zones Unable To Attach and Zone Service Group is Faulted on All The Nodes
 
Description: There is a package mismatch inside global zone and the local zone, and the package inside the local zone are not updated during the full upgrade as the zones are in configured state.
 
Workaround:
Steps to Make the Zone Group Online and Test The Failover:
   Clear the zone group which is in faulted --> /opt/VRTS/bin/hagrp -clear <zone_group> -any
   make the zone resource offline on current machine of the cluster--> /opt/VRTS/bin/hares -offline <zone_res> -sys <sysA>
   Check if zone is in configured state
   Set Publisher Veritas for the Packages and Patches which have been installed with the Full upgrade, Also Set VRTSpython Package Publisher To Resolve The Package Dependencies.
   run the command 'zoneadm -z <zonename> attach -u'
   Once attach is successful, zone will transition into 'installed' state.
   Now check if all the packages in the zone are upgraded to the latest version.
   Kernel packages like VRTSodm and VRTSvxfs may be left without upgraded to newer version as they need extra handling.
   To upgrade the VRTSodm/VRTSvxfs inside the zone , run the below command:
   pkg -R <zonepath>/root uninstall VRTSodm VRTSvxfs --> This will uninstall the VRTSodm/VRTSvxfs
   pkg -R <zonepath>/root install --accept --no-backup-be VRTSodm VRTSvxfs
These steps needs to be performed on all the systems of the cluster one by one.
Once all the systems are updated, make the zone group online on any system by running:
/opt/VRTS/bin/hagrp -online <zone_group> -sys <sys>
Once zone group comes online test the failover by switching the zone group on other machine:
/opt/VRTS/bin/hagrp -switch <zone_group> -to <sys>
-------------------------------------------------------------------------------------------------------------------------------------------------
Issue: When upgrading to 7.4.1U6 on SOL11.3, CollectorService fails to start on SOL11.3

Description: This issue is seen when 7.4.1U6 patch is installed on SOL11.3 first, and then OS is upgraded.

Workaround: When upgrading to 7.4.1U6, upgrade the OS first to SOL11.4, and then proceed with the upgrade to 7.4.1U6.


OTHERS
------