Storage Foundation and High Availability Solutions 5.0
Main Menu > Check systems for SFRAC ** INSTRUCTIONS ONLY **
. ............................................................... .
This step helps you detect problems with LLT links and I/O fencing disks
. ............................................................... .
1) [Perform all the following tasks]
2) Check LLT links ** INSTRUCTIONS ONLY **
3) Check I/O fencing disks ** INSTRUCTIONS ONLY **
Storage Foundation and High Availability Solutions 5.0
Main Menu > Check systems for SFRAC > Check LLT links ** INSTRUCTIONS ONLY **
. ............................................................... .
Before continuing, login to all cluster nodes and check LLT links. Each LLT link must:
* Not share a subnet with other LLT links on that system
* Have speed and autonegotiate settings matching with the network switch port
* Have same jumbo frame settings
* Must have unique MAC addresses
/usr/sbin/lanadmin -x 1 #to query speed and autonegotiate
/usr/sbin/lanadmin -m 1 #to query jumbo frame
. ............................................................... .
Storage Foundation and High Availability Solutions 5.0
Main Menu > Check systems for SFRAC > Check I/O fencing disks ** INSTRUCTIONS ONLY **
. ............................................................... .
Before continuing, login to all cluster nodes and check I/O fencing disks.
* Identify at least three SCSI3 PGR compliant shared disks as coordinator disks
* Test the shared disks using /opt/VRTSvcs/vxfen/bin/vxfentsthdw script. *NOTE* Running this script is DESTRUCTIVE.
. ............................................................... .
Storage Foundation and High Availability Solutions 5.0
Main Menu > Check systems for SFRAC ** INSTRUCTIONS ONLY **
. ............................................................... .
This step helps you detect problems with LLT links and I/O fencing disks
. ............................................................... .
1) [Perform all the following tasks]
2) Check LLT links ** INSTRUCTIONS ONLY **
3) Check I/O fencing disks ** INSTRUCTIONS ONLY **