vxfenconfig

NAME

vxfenconfig - Configure the vxfen driver used in I/O fencing.

SYNOPSIS

vxfenconfig -c [-s]

vxfenconfig -v

vxfenconfig -U

AVAILABILITY

VRTSvxfen

DESCRIPTION

The vxfenconfig command configures the vxfen driver using parameters found in /etc/vxfenmode file. For a list of possible parameters and usage information please see the manpage for /etc/vxfenmode file. If this file is omitted I/O Fencing defaults to SCSI3 functionality. When running in scsi3 mode, vxfenconfig command configures the vxfen driver using the coordinator disks listed in the /etc/vxfentab file. Disks must be listed by the full file name of the raw or DMP device. A minimum of three coordinator disks must be used (unless the -s option is specified to configure the driver); in total, an odd number of disks must be used.

OPTIONS

-c

Configure the vxfen driver.

[-s]

Configure the vxfen driver for use with only a single coordinator disk. The default (and Veritas recommendation) is three coordinator disks.

WARNING: When I/O fencing is configured to use only one coordinator disk, the loss of the single coordinator disk results in the loss of the availability of all applications in the cluster.

-U

Unconfigure the vxfen driver.

-v

Print out the version information.

FILES

/etc/vxfentab

Contains the list of coordinator disks, each of which is identified by the full file name of the raw device. A minimum of three disks must be configured in normal cases (except in the case of the [-s] option). Multiple paths can also be listed. The /etc/vxfentab file is created by the rc script based on the contents of the /etc/vxfendg file. An example /etc/vxfentab file may contain the following lines:

For Solaris:

/dev/rdsk/c1t1d0s2

/dev/rdsk/c2t1d0s2

/dev/rdsk/c3t1d0s2

For Linux:

/dev/sdc

/dev/sdd

/dev/sde

For HP-UX:

/dev/rdsk/c1t1d0

/dev/rdsk/c2t1d0

/dev/rdsk/c3t1d0

For AIX:

/dev/rhdisk20

/dev/rhdisk21

/dev/rhdisk22

/etc/vxfendg

Contains the name of the disk group containing the coordinator disks. Typically, this disk group is vxfencoorddg. /etc/vxfendg must exist on each system in the cluster.

EXAMPLES

To run I/O Fencing in disabled mode, add the following line to /etc/vxfenmode

vxfen_mode=disabled

WARNING: Veritas does not support SFRAC clusters using I/O fencing in the disabled mode (vxfen_mode=disabled).

To run I/O Fencing in customized/sanvm mode, add the following lines to /etc/vxfenmode

vxfen_mode=customized

vxfen_mechanism=sanvm

SEE ALSO

vxfenadm(1M), vxfentsthdw(1M), vxfendebug(1M), vxfenmode(4M), vxfenclearpre(1M)