To display the current settings for handling I/O request failures that are applied to the paths to an enclosure, array name or array type, use the following command:
# vxdmpadm getattr \ {enclosure enc-name|arrayname name|arraytype type} \ recoveryoption
The following example shows the vxdmpadm getattr command being used to display the recoveryoption option values that are set on an enclosure.
# vxdmpadm getattr enclosure HDS9500-ALUA0 recoveryoption ENCLR-NAME RECOVERY-OPTION DEFAULT[VAL] CURRENT[VAL] =============================================================== HDS9500-ALUA0 Throttle Nothrottle[0] Timebound[60] HDS9500-ALUA0 Error-Retry Fixed-Retry[5] Timebound[20]
This shows the default and current policy options and their values.
Table: Recovery options for retrying I/O after an error summarizes the possible recovery option settings for retrying I/O after an error.
Table: Recovery options for retrying I/O after an error
Table: Recovery options for I/O throttling summarizes the possible recovery option settings for throttling I/O.