The following table contains VXFEN driver error messages.
Unable to register with coordinator disk with serial number: xxxx |
This message appears when the vxfen driver is unable to register with one of the coordinator disks. The serial number of the coordinator disk that failed is printed. |
Unable to register with a majority of the coordinator disks. Dropping out of cluster. |
This message appears when the vxfen driver is unable to register with a majority of the coordinator disks. The problems with the coordinator disks must be cleared before fencing can be enabled. This message is preceded with the message "VXFEN: Unable to register with coordinator disk with serial number xxxx." |
There exists the potential for a preexisting split-brain. The coordinator disks list no nodes which are in the current membership. However, they, also list nodes which are not in the current membership. |
This message appears when there is a preexisting split-brain in the cluster. In this case, the configuration of vxfen driver fails. Clear the split-brain using the instructions given in the Troubleshooting Storage Foundation before configuring vxfen driver. |
Unable to join running cluster since cluster is currently fencing a node out of the cluster |
This message appears while configuring vxfen driver, if there is a fencing race going on in the cluster. The vxfen driver can be configured by retrying after sometime (after the cluster completes the fencing). |
Unable to register with coordinator disk with serial number: xxxx
This message appears when the vxfen driver is unable to register with one of the coordinator disks. The serial number of the coordinator disk that failed is printed.
Unable to register with a majority of the coordinator disks. Dropping out of cluster.
This message appears when the vxfen driver is unable to register with a majority of the coordinator disks. The problems with the coordinator disks must be cleared before fencing can be enabled.
This message is preceded with the message "VXFEN: Unable to register with coordinator disk with serial number xxxx."
There exists the potential for a preexisting split-brain.
The coordinator disks list no nodes which are in the current membership. However, they, also list nodes which are not in the current membership.
This message appears when there is a preexisting split-brain in the cluster. In this case, the configuration of vxfen driver fails. Clear the split-brain using the instructions given in the Troubleshooting Storage Foundation before configuring vxfen driver.
Unable to join running cluster since cluster is currently fencing a node out of the cluster
This message appears while configuring vxfen driver, if there is a fencing race going on in the cluster. The vxfen driver can be configured by retrying after sometime (after the cluster completes the fencing).