Symantec logo

Upgrading cluster monitor to cluster connector
on Windows platforms

You must perform this upgrade on each cluster that formerly used CommandCentral Availability cluster monitor to communicate with the CommandCentral Availability management server.

 To upgrade cluster monitor to cluster connector

  1. In CommandCentral Availability, locate and record the value of the GUID attribute. This attribute is on the CCAvail_ClusterConfig resource.
  2. Uninstall cluster monitor on each cluster node.

    Refer to the CommandCentral Availability documentation for cluster monitor uninstallation instructions.

  3. Insert the distribution disc into the DVD drive on the cluster node.
  4. Obtain a command prompt and navigate to the \installer directory.
  5. At the command line, enter the following command:

    setup.bat -guid xxxxxx

    where xxxxxx is the value of the GUID attribute you recorded in step 1. The setup program installs the Cluster Management Console cluster connector.

For information on the documentation that comes with this release, see: